Preferred Language
Articles
/
ihbImIoBVTCNdQwCu6D1
Synthesis And Characterisation Of Some Lanthanide Ion(III) ComplexesWith Mixed Ligands (Nicotinamide And Benzimidazole)
...Show More Authors

Complexes of Lanthanide ione Ln(III) =La(III) , Ce(III),Pr(III) and Nd(III) withligands of nicotinamide (na) and Benzimidazole (BIMD) have been prepared withgeneral formula [M(na)3(BIMD)3](NO3) where :M = Ln(III) = La(III) , Ce(III) , Gd(III) , Nd(III) .Na = nicotinamide = C7H6N2OBIMD = Benzimidazole = C7H6N2All compounds have been characterized by spectroscopic methods [FT-IR , UV-VIS ,AAS] , microanalysis (C.H.N) Along with conductivity measurements , solubility ,melting point , theroitical measurment by using chem office 3D prog .Model (2000) .Frome the above data the proposed moleculer structure for all complexes with its ionsis octahydral geometries

Preview PDF
Quick Preview PDF
Publication Date
Thu Feb 01 2024
Journal Name
Russian Journal Of Bioorganic Chemistry
Synthesis, Identification, Antioxidant, Molecular Docking, and In Silico ADME Study for Some New Derivatives Containing Thiourea Moiety
...Show More Authors

Objective: Synthesized a series of new thiourea (TU) derivatives, tested their antioxidant activity, and investigated their expected biological activity by theoretical study (computational methods). Methods: The derivatives were made using a one-pot reaction with two steps. Initially, succinyl chloride was mixed with KSCN to make succinyl isothiocyanate. Then, primary and secondary amines were used to make TU derivatives. The theoretical studies were done by Swiss ADME and molecular docking via Genetic Optimization of Linkage Docking (GOLD). Then evaluate antioxidant activity using the DPPH scavenging method. Results: FT-IR, 1H NMR, and 13C NMR spectroscopy show the verification of all the prepared derivatives. Compounds (II), (VIII),

... Show More
View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Indonesian Journal Of Electrical Engineering And Computer Science
Comparison hybrid techniques-based mixed transform using compression and quality metrics
...Show More Authors

Image quality plays a vital role in improving and assessing image compression performance. Image compression represents big image data to a new image with a smaller size suitable for storage and transmission. This paper aims to evaluate the implementation of the hybrid techniques-based tensor product mixed transform. Compression and quality metrics such as compression-ratio (CR), rate-distortion (RD), peak signal-to-noise ratio (PSNR), and Structural Content (SC) are utilized for evaluating the hybrid techniques. Then, a comparison between techniques is achieved according to these metrics to estimate the best technique. The main contribution is to improve the hybrid techniques. The proposed hybrid techniques are consisting of discrete wavel

... Show More
View Publication
Scopus (4)
Scopus Crossref
Publication Date
Sat Nov 02 2013
Journal Name
International Journal Of Computer Applications
Mixed Transforms Generated by Tensor Product and Applied in Data Processing
...Show More Authors

Finding orthogonal matrices in different sizes is very complex and important because it can be used in different applications like image processing and communications (eg CDMA and OFDM). In this paper we introduce a new method to find orthogonal matrices by using tensor products between two or more orthogonal matrices of real and imaginary numbers with applying it in images and communication signals processing. The output matrices will be orthogonal matrices too and the processing by our new method is very easy compared to other classical methods those use basic proofs. The results are normal and acceptable in communication signals and images but it needs more research works.

View Publication
Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Journal Of Engineering
REMOVAL OF COPPER ION FROM WASTEWATER BY FLOTATION
...Show More Authors

Several industrial wastewater streams may contain heavy metal ions, which must be effectively removal
before the discharge or reuse of treated waters could take place. In this paper, the removal of copper( II)
by foam flotation from dilute aqueous solutions was investigated at laboratory scale. The effects of
various parameters such as pH, collector and frother concentrations, initial copper concentration, air flow
rate, hole diameter of the gas distributor, and NaCl addition were tested in a bubble column of 6 cm inside
diameter and 120 cm height. Sodium dodecylsulfate (SDS) and Hexadecyl trimethyl ammonium bromide
(HTAB) were used as anionic and cationic surfactant, respectively. Ethanol was used as frothers and the

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Dynamic Behavior of Pb(II) and Cr(III) Biosorption onto Dead Anaerobic Biomass in Fixed-Bed Column, Single and Binary Systems
...Show More Authors

The biosorption of lead (II) and chromium (III) onto dead anaerobic biomass (DAB) in single and binary systems has been studied using fixed bed adsorber. A general rate multi- component model (GRM) has been utilized to predict the fixed bed breakthrough curves for single and dual- component system. This model considers both external and internal mass transfer resistances as well as axial dispersion with non-liner multi-component isotherm (Langmuir model). The effects of important parameters, such as flow rate, initial concentration and bed height on the behavior of breakthrough curves have been studied. The equilibrium isotherm model parameters such as maximum uptake capacities for lead (II) and chromium (III) were found to be 35.12 and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Mar 17 2012
Journal Name
Environmental Science And Pollution Research Volume
Equilibrium, kinetic, and thermodynamic biosorption of Pb(II), Cr(III), and Cd(II) ions by dead anaerobic biomass from synthetic wastewater
...Show More Authors

Purpose Heavy metals are toxic pollutants released into the environment as a result of different industrial activities. Biosorption of heavy metals from aqueous solutions is a new technology for the treatment of industrial wastewater. The aim of the present research is to highlight the basic biosorption theory to heavy metal removal. Materials and methods Heterogeneous cultures mostly dried anaerobic bacteria, yeast (fungi), and protozoa were used as low-cost material to remove metallic cations Pb(II), Cr(III), and Cd(II) from synthetic wastewater. Competitive biosorption of these metals was studied. Results The main biosorption mechanisms were complexation and physical adsorption onto natural active functional groups. It is observed that

... Show More
View Publication Preview PDF
Crossref (54)
Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
MIXED CONVECTIVE AND RADIATIVE HEAT TRANSFER IN A HORIZONTAL CONCENTRIC AND ECCENTRIC CYLINDRICAL ANNULI
...Show More Authors

A numerical investigation has been performed to study the effect of eccentricity on unsteady state, laminar aiding mixed convection in a horizontal concentric and eccentric cylindrical annulus. The outer cylinder was kept at a constant temperature
while the inner cylinder was heated with constant heat flux. The study involved numerical solution of transient momentum (Navier-Stokes) and energy equation using finite difference method (FDM), where the body fitted coordinate system (BFC) was
used to generate the grid mesh for computational plane. The governing equations were transformed to the vorticity-stream function formula as for momentum equations and to the temperature and stream function for energy equation.
A computer progra

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Dec 31 2018
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ESTIMATION OF ELLAGIC ACID ACTIVITY WHEN MIXED WITH SOME TYPES OF CANDY AGAINST Streptococcus mutans ISOLATED FROM ADULT PATIENTS IN BAGHDAD CITY: ESTIMATION OF ELLAGIC ACID ACTIVITY WHEN MIXED WITH SOME TYPES OF CANDY AGAINST Streptococcus mutans ISOLATED FROM ADULT PATIENTS IN BAGHDAD CITY
...Show More Authors

Microbial activity of Ellagic acid when mixed with some types of candy toward Streptococcus mutans microorganism was studied. The main purpose of carrying out this study is to produce a new type of candy that contains Ellagic acid in addition to xylitol instead of sucrose to prevent dental caries. The results show that the inhibitory action of Ellagic acid was more effective when mixed with this type of candy for the purpose of reducing Streptococcus mutans microorganisms, while sensory evaluation was applied in this study to 20 volunteers to that candy sample evaluated which contain (5 mg/ml) Ellagic acid with 100g xylitol to determine consumers acceptability of this sample of candy. The results were expressed as mean value, slandered d

... Show More
View Publication Preview PDF
Publication Date
Mon Mar 08 2021
Journal Name
Baghdad Science Journal
synthesis and characterization
...Show More Authors

chloride or poluacrulic acid with different primary amines to mesuring==================================638one hundred three patinents with rheumatic symptoms were include in this study and their sera tested for

View Publication Preview PDF
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
Derivative Zero - Crossing Spectrophotometry Of Binary Mixtures Of Acetyl Acetonates Of Micro – Amounts Of Mn (Ii) And Al (Iii).
...Show More Authors

New derivative molecular absorption spectrophotometric methods have been developed for the determination of Al (III) , Mn (II) , individually and binary mixtures . The aim of this model of study is to obtain analytical results characterized by adequate standard of analytical figures of merits through application of derivative Spectrophotometry (dnA/d?n). The two metals acetyl acetonates are chemically stable and are widely used as catalysts . Where Interferences are probable due to very close or nearby peaks or Summits, the Zero – Crossing derivative measurement technique is used to avoid interfering effects between two metals pairs.

View Publication Preview PDF
Crossref