Lower limb Rehabilitation Robots (LLRRs) assist in therapeutic tasks that involve gait recovery and joint mobility recovery of the lower limbs, in patients recovering from neurologic injuries such as stroke as well as spinal cord injury. LLRRs can sometimes be driven by preprogrammed trajectories or Inverse Kinematics (IK) trajectories, which bring increased computational demand and command supported interaction. This paper proposes an interactive control framework for LLRRs using a hybrid mix of Forward Kinematics (FK) driven movement and an offline Voice Conversational Agent (VCA), based on the Vosk speech recognition engine. The framework proposed is modular in nature that is completely “local”, running offline with no need for the Internet, preserving privacy, and not needing to send uploads cards to cloud processing units. Spoken commands, such as “forward”, “backward”, “rest”, “exercise”, and “stop” are mapped to hip and knee joint angles, which are then driven to FK equations for deriving leg segment positions in an ongoing manner. A hybrid MATLAB-Python implementation is used, where MATLAB is used for simulation and animation, while Python captures the audio input and runs the offline speech recognition component. Recognized transcripts are resolved through fuzzy command matching and are followed by a confidence gated execution to improve tolerance to Automatic Speech Recognition (ASR) variability. Under controlled conditions, command recognition accuracy ranging from 80% to 95%, with end-to-end latencies ranging from 0.89 to 1.32 sec. were seen for the evaluated commands. The performance of feasible offline voice guided interaction and reasonably smooth, anatomically consistent motion transitions, as shown in simulation, provide evidence for the working of the proposed architecture. The main contribution of the work lies in the explicit exposure of ASR offline, fuzzy command matching, applying confidence gated execution, and the use of FK based motion generation, all within a lightweight LLRR oriented framework. This should be enough substrate for future hardware validation, and phase synchronized wearables deployment.
The samples were collected monthly crustaceans Mjmafah foot of two stations in tributary Zab down and two others in the Tigris River for one year with effect from November 2001 until October 2002 recorded during the study period the current 41 units taxonomic and were higher density of Mjmafah foot Guy Tigris River before the mouth of the tributary
This paper presents a novel inverse kinematics solution for robotic arm based on artificial neural network (ANN) architecture. The motion of robotic arm is controlled by the kinematics of ANN. A new artificial neural network approach for inverse kinematics is proposed. The novelty of the proposed ANN is the inclusion of the feedback of current joint angles configuration of robotic arm as well as the desired position and orientation in the input pattern of neural network, while the traditional ANN has only the desired position and orientation of the end effector in the input pattern of neural network. In this paper, a six DOF Denso robotic arm with a gripper is controlled by ANN. The comprehensive experimental results proved the appl
... Show MoreBiped robots have gained much attention for decades. A variety of researches has been conducted to make them able to assist or even substitute for humans in performing special tasks. In addition, studying biped robots is important in order to understand the human locomotion and to develop and improve control strategies for prosthetic and orthotic limbs. Some challenges encountered in the design of biped robots are: (1) biped robots have unstable structures due to the passive joint located at the unilateral foot-ground contact. (2) They have different configuration when switching from walking phase to another. During the singlesupport phase, the robot is under-actuated, while turning into an over-actuated system during the double-support pha
... Show MoreAbstract
This paper presents mechanical and electrical design, and implementation process of industrial robot, 3-DoF type SCARA (selective compliment assembly robot arm),with two rotations and one translation used for welding applications.The design process also included the controller design which was based on PLC(programmable logic controller) as well as selection of mechanical and electrical components.The challenge was to use the available components in Iraq with reasonable costs. The robot mentioned is fully automated using programmable logic controller PLC(Zelio type SR3-B261BD),with 16inputs and 10 outputs. The PLC was implemented in FBD logic to obtain three different automatic motions with hi
... Show MorePathology reports are necessary for specialists to make an appropriate diagnosis of diseases in general and blood diseases in particular. Therefore, specialists check blood cells and other blood details. Thus, to diagnose a disease, specialists must analyze the factors of the patient’s blood and medical history. Generally, doctors have tended to use intelligent agents to help them with CBC analysis. However, these agents need analytical tools to extract the parameters (CBC parameters) employed in the prediction of the development of life-threatening bacteremia and offer prognostic data. Therefore, this paper proposes an enhancement to the Rabin–Karp algorithm and then mixes it with the fuzzy ratio to make this algorithm suitable
... Show MoreThis investigation presents an experimental and analytical study on the behavior of reinforced concrete deep beams before and after repair. The original beams were first loaded under two points load up to failure, then, repaired by epoxy resin and tested again. Three of the test beams contains shear reinforcement and the other two beams have no shear reinforcement. The main variable in these beams was the percentage of longitudinal steel reinforcement (0, 0.707, 1.061, and 1.414%). The main objective of this research is to investigate the possibility of restoring the full load carrying capacity of the reinforced concrete deep beam with and without shear reinforcement by using epoxy resin as the material of repair. All be
... Show MoreIn this study, structures damage identification method based on changes in the dynamic characteristics
(frequencies) of the structure are examined, stiffness as well as mass matrices of the curved
(in and out-of-plane vibration) beam elements is formulated using Hamilton's principle. Each node
of both of them possesses seven degrees of freedom including the warping degree of freedom. The
curved beam element had been derived based on the Kang and Yoo’s thin-walled curved beam theory
in 1994. A computer program was developing to carry out free vibration analyses of the curved
beam as well as straight beam. Comparing with the frequencies for other researchers using the general
purpose program MATLAB. Fuzzy logic syste
Background: Transplantation has revolutionized
treatment of end- stage renal disease (ESRD) by proving
more cost effective than hemodialysis, with a lower
morbidity and improved quality of life.
Objective: To evaluate the development of these
complications in the first month postoperatively and
correlate their development to the type of donation
whether related or unrelated.
Methods: Fifty (50) patients aged (15-62) years, with a
mean age (34.46 ± 12.4 SD) years with (ESRD), who
underwent renal transplantation from September 2000 to
October 2002, were followed-up for one month
postoperatively clinically and by assessment of renal
function tests, sonographic and Doppler examinations.
Ureteral obs