Preferred Language
Articles
/
iRc-cJABVTCNdQwCNIou
SIMPLEX OPTIMIZATION FOR THE SPECTROPHOTOMETRIC DETERMINATION OF AZITHROMYCIN DRUG VIA ION-PAIR FORMATION
...Show More Authors

A spectrophotometric determination of azithromycin was optimized using the simplex model. The approach has been proven to be accurate and sensitive. The analyte has been reacted with bromothymol blue (BTB) to form a colored ion pair which has been extracted in chloroform in a buffer medium of pH=4 of potassium phthalate. The extracted colored product was assayed at 415 nm and exhibited a linear quantification range over (1 - 20) g/ml. The excipients did not exhibit any interferences with the proposed approach for assaying azithromycin in pharmaceutical formulations.

Scopus
View Publication
Publication Date
Fri Aug 14 2020
Journal Name
Iop Conference Series: Earth And Environmental Science
Removal of Cadmium(II) ion from aqueous solutions by the outer layer of Onion
...Show More Authors
Abstract<p>Cadmium element is one of the group IIB and classified as heavy metal and effects on human health and environment. The present work concerns with the biosorption of Cd(II) ions from aqueous solution using the outer layer of onions. Adsorption of the used ions was found to be pH dependent and maximum removal of the ions by outer layer of onions and was found to be 99.7%.</p>
Preview PDF
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Effect of Amoxicillin and Azithromycin Suspensions on Microhardness of Sliver Reinforced and Nano Resin-Modified Glass Ionomers: An In Vitro Study
...Show More Authors

We aimed to examine the effect of amoxicillin and azithromycin suspensions on the microhardness of sliver-reinforced glass ionomer and nano-resin modified glass ionomer (GI). Method: Thirty discs (2mm height x 4mm diameter) of each type of GI were prepared, which were randomly assigned to amoxicillin, azithromycin, and artificial saliva groups. Microhardness was evaluated by Vickers hardness test before and after three immersion cycles. Results: The overall model (P < 0.001), before/after intervention (P < 0.001), intervention group (type of antibiotic) (P=0.013), and type of glass ionomer (P < 0.001) showed significant differences among study groups (P < 0.001). Post hoc test showed only non-significant before/after difference for Azithrom

... Show More
View Publication Preview PDF
Crossref (5)
Clarivate Crossref
Publication Date
Wed Mar 10 2021
Journal Name
Baghdad Science Journal
THIAMINE – INDUCED FORMATION OF THE MONOPYRROLE MOIETY OF PRODIGIOSIN
...Show More Authors

Thiamine stimulates the production of a red pigment , which is chromatographically and spectrophotometrically identical to prodigiosin , by growing cultures of serratia marcescens mutant 9-3-3 . this mutant is blocked in the formation of 2- methyl -3- amyl pyrorol( MAP),the monopyrrole moiety of prodigiosin , but accumulates 4-methoxy-2, 2-bipyrrole -5- carboxaldehyde (MBC) and can couple this compound with( MAP) to form prodigiosin . Addition of thiamine caused production of( MAP) , and as little as 0.02 mg of thiamine / ml in peptone- glycerol medium stimulated production of measurable amounts of prodigiosin. Phosphate saltes and another type of peptone decreased the thiamine- induced formation of prodigiosin ,yeast extract and glyc

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
View Publication Preview PDF
Scopus (22)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Jul 01 2021
Journal Name
Journal Of Pharmaceutical And Biomedical Analysis
An optoelectronic flow-through detectors for active ingredients determination in the pharmaceutical formulations
...Show More Authors

An optoelectronic flow-through detector for active ingredients determination in pharmaceutical formulations is explained. Two consecutive compact photodetector’s devices operating according to light-emitting diodes-solar cells concept where the LEDs acting as a light source and solar cells for measuring the attenuated light of the incident light at 180˚ have been developed. The turbidimetric detector, fabricated of ten light-emitting diodes and five solar cells only, integrated with a glass flow cell has been easily adapted in flow injection analysis manifold system. For active ingredients determination, the developed detector was successfully utilized for the development and validation of an analytical method for warfarin determination

... Show More
Scopus (22)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Al-kindy College Medical Journal
Drug Resistant Epilepsy Among Patients Attended The Neurosciences Hospital
...Show More Authors

Background: Drug resistant epilepsy is defined as failure of adequate trials of two tolerated, appropriately chosen and used antiepileptic drug schedules to achieve sustained seizure freedom. Up to 30% of patients referred to clinics with a diagnosis of pharmaco-resistant epilepsy may have been misdiagnosed, and many can be helped by optimizing their treatment.Pseudoresistance, in which seizures persist because the underlying disorder has not been adequately or appropriately treated, must be ruled out or corrected before drug treatment can be considered to have failed.

Objectives: The objectives of this study were to determine the causes of drug failure in patients with epilepsy and to differenti

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Jun 30 2003
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Water Treatment of Cooling Towers Blowdown by Ion Exchange
...Show More Authors

View Publication Preview PDF
Publication Date
Tue Dec 01 2009
Journal Name
Iraqi Journal Of Physics
Simulation of an ion Optical Transport and Focusing System
...Show More Authors

A simulated ion/electron optical transport and focusing system has been put forward to
be mounted on high voltage transmission electron microscope for in situ investigations.
The suggested system consists of three axially symmetric electrostatic lenses namely an
einzel lens, an accelerating immersion lens, and a decelerating immersion lens, in addition
to an electrostatic quadrupole doublet lens placed on the image side. The electrodes
profile of these lenses is determined from the proposed axial field distributions. The
optical properties of the whole system have been computed together with the trajectory of
the accelerated charged-particles beam along the optical axis of the system. The computed
dimensions of th

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 01 2017
Journal Name
Physics Letters A
Wake potential of swift ion in amorphous carbon target
...Show More Authors

The wake potential and wake phenomena for swift proton in an amorphous carbon target were studied by utilising various dielectric function formalisms, including the Drude dielectric function, the Drude–Lorentz dielectric function and quantum dielectric function. The Drude model results exhibited a damped oscillatory behaviour in the longitudinal direction behind the projectile; the pattern of these oscillations decreases exponentially in the transverse direction. In addition, the wake potential extends slightly ahead of the projectile which also depends on the proton coordinate and velocity. The effect of electron binding on the wake potential, characterised by the ratio to 0.1, has been studied alongside the Drude–Lorentz dielectric

... Show More
View Publication
Scopus (8)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Bio Web Of Conferences
Dynamic TWGH: Client-Server Optimization for Scalable Combinatorial Test Suite Generation
...Show More Authors

To ensure that a software/hardware product is of sufficient quality and functionality, it is essential to conduct thorough testing and evaluations of the numerous individual software components that make up the application. Many different approaches exist for testing software, including combinatorial testing and covering arrays. Because of the difficulty of dealing with difficulties like a two-way combinatorial explosion, this brings up yet another problem: time. Using client-server architectures, this research introduces a parallel implementation of the TWGH algorithm. Many studies have been conducted to demonstrate the efficiency of this technique. The findings of this experiment were used to determine the increase in speed and co

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref