BACKGROUND: Acute coronary syndrome (ACS) is the clinical manifestation of acutely diminished coronary arterial blood supply. The rate of increase of intraventricular pressure during isovolumetric contraction (left ventricular dP/dt) represents the rate of change of pressure during ejection. OBJECTIVE: The aim of this study is to evaluate the usefulness of the rate of increase of intraventricular pressure during isovolumetric contraction (dP/dt) in assessment of left ventricular function in patients with acute coronary syndrome and its relation to certain clinical and echocardiographic features. PATIENTS AND METHODS: The study is a cross sectional study including 50 patients with an established diagnosis of acute coronary syndrome. The study was performed in Baghdad Teaching Hospital during the period between 2/2/2013 and 5/3/2014. History was taken from all patients and recoded using a specially prepared questionnaire paper. Left ventricular internal dimensions at end diastole (LVIDd) and end systole (LVIDs) were measured using M-mode echocardiography to asses left ventricular systolic function (ejection fraction). Pulse Doppler tracing of the transmitral flow velocities and tissue Doppler image (TDI) mitral annular velocities were obtained from the apical four-chamber view to assess left ventricular diastolic function. Doppler-derived dP/dt was determined from mitral regurgitation (MR) spectral flow RESULTS: The study included 50 patients (31 males and 19 females, mean age of 65.26 ± 5 years). Low dP/dt values were found in 42 patients (84%). Low dP/dt values were found more in the age group (51-60 yrs) (p value < 0.05). The mean age of patients with low dP/dt (<1000) was (65.62 ± 5yrs) and that of patients with normal dP/dt (≥ 1000) was (63.38 ± 5 yrs) with no significant difference (p value > 0.05). Low dP/dt value was significantly associated with smoking and positive family history and not significantly associated with male sex, hypertension, and diabetes mellitus. No significant association was found between low dP/dt value and type of presentation of acute coronary syndrome (p value > 0.05) or ejection fraction (p value > 0.05). It was significantly associated with LV diastolic dysfunction, left atrial size, left atrial pressure, and left ventricular size (p value < 0.05). CONCLUSION: The use of dP/dt is useful for evaluating left ventricular function in patients with acute coronary syndrome.
This paper aims to review the intellectual to the most important thought leaders administrative and strategic They both (Henry Fayol and Michelle Porter), who forward a lot of ideas that have helped countries in the advancement and progress their economies , has been drawing literature theoretical common border in Contributions ( Fayol ) philosophical and between applications ( Porter ), which reversed strategies of the three ( the leadership of the cost, differentiation, and focus ), so browse search how to apply and use the principles of Fayol in the implementation of strategies competitiveness of Porter, and stems from a problem ( ( to what extent a reflection of the principles ( Fayol) fourteen strategies (Porter ) competitiv
... Show MoreAbstract:
The research aims to identify the concept of trading securities in Iraq and to propose a new mechanism for the taxation of trading profits and the extent of its impact on tax revenues, as it was observed that there are professional investors in the trading market and some of them achieve huge annual profits. and this profit should be like other taxable profits. The General Commission of Taxes and in cooperation with the Iraq Stock Exchange should identifying those profits, subjecting them to income tax, and adding them to the tax base. The researcher relied on the use of the descriptive and analytical approach bas
... Show MoreThe study aimed to investigate the effect of using the intructional computer individually or through the cooperative groups on the achievement of the ninth grade students in mathematics compared to the traditional method. The experimental method adapted three groups out of three schools were chosen, two groups of the students where applied the computer method. The comtrol group used the simple random method, and it used the diagnostic test as tool for the study.The result showed that there is a statistically significant difference between the mean scores of the experimental groups and the control group on the post-test for the two experimental groups.
In this research, radon concentrations in some types of healthy drinking water samples available in Iraq's market were measured using a technique called Durridge RAD-7-H2O with closed loop. Then the rate of annual effective dose in human taken this water is determined.
It was found that, radon concentrations in studied samples ranged between 1.2 Bq.m-3 to 142 Bq.m-3. The results of the radon concentrations and the rate of annual effective dose for drinking water samples were significantly lower than the USEPA and WHO recommended limits that equal 500 Bq/m3 and 1 mSv/y resp
... Show MoreIn this paper, we investigate and study quantum theoretical of quark-gluon interaction modeling in QGP matter formatted. In theoretical modeling, we can use a flavor number, strength coupling, critical energy Tc = 190 MeV, system energy (400-650)MeV, fugacity of quark and gluon, and photon energy in range of 1-10 GeV parameter to calculation and investigation spectrum of photon rate. We calculation and study the photon rate produced through bremsstrahlung processes from the stable QGP matter. The photon rate production from cg → dgy systems at bremsstrahlung processes are found to be increased with increased fugacity, decreased strength coupling, decreased the photons energy and temperature of system. The photons rate in cg → dgy is inc
... Show MoreBackground: Gray-scale sonography is generally
considered as a first-line diagnostic tool for patient with
suspected acute cholecystitis. It is suggested by gallstones,
Murphy's sign, thickening of the gallbladder wall and bile
sludging, but the specificity of these sonographic findings
are not as high as their sensitivity. Blood flow of the
gallbladder wall is increased in acute inflammation.
Objective: To evaluate the sensitivity and specificity of
power Doppler sonography and compared with conventional
color Doppler and gray-scale sonography in diagnosing
patients with acute cholecystitis.
Type of the study: This was a cross sectional study.
Patients and methods: The study was conducted t
Age, hypertension, and diabetes can cause significant alterations in arterial structure and function, including changes in lumen diameter (LD), intimal-medial thickness (IMT), flow velocities, and arterial compliance. These are also considered risk markers of atherosclerosis and cerebrovascular disease. A difference between right and left carotid artery blood flow and IMT has been reported by some researchers, and a difference in the incidence of nonlacunar stroke has been reported between the right and left brain hemispheres. The aim of this study was to determine whether there are differences between the right and left common carotid arteries and internal carotid arteries in patient
The acute phase response is a major pathophysiologic phenomenon that accompanies inflammation whether acute or chronic. Complement (C3 and C4) and C - reactive protein (CRP) are positive acute phase proteins (+ ve APPs ). Their production takes place in hepatocyte and the blood concentration of these parameters are increased in osteoarthritis (OA). Chloroquine (CQ) is a diprotic weak base traditionally used to treat malaria. Recently the phosphate salt of CQ is used to decrease this type of (+ve APPs) . In this study, patients who suffered from knee osteoarthritis (KOA) are treated with oral dosage form of chloroquine phosphate (CQP) for one month, twice daily. Our results demonstrate that CQP improves the patient status by decreas
... Show More