Assessment of annual wind energy potential for three selected sites in Iraq has been analyzed in the present work. The wind velocities data from August 2014 to July 2015 were collected from the website of Weather Underground Organization (WUO) at stations elevation (35m, 32m, and 17m) for Baghdad, Najaf, and Kut Al-Hai respectively. Extrapolation of stations elevation and wind velocities was used to estimate wind velocities at (60m, 90m, and 120m). The objectives are to analyze the wind speed data and assess the wind energy potential for wind energy applications. Computer code for MATLAB software has been developed to solve the mathematical model. The results are presented as a monthly and annual average for wind velocities, standard deviation, shape factor, scale factor, probability density function, cumulative distribution function, measured and Weibull estimated of wind power density, wind energy density, determination factor, and root mean square error. A comparison is made with the previous studies to select wind class of selected sites in the present work. At selected stations, the wind energy potential was the best for Najaf, Kut Al-Hai, and Baghdad respectively. According to the international wind classification, the selected sites has fair class at stations elevation. Kut Al-Hai has fairly good class at selected heights. While Najaf have fairly good at (90m, and 120m) whereas Baghdad has a fairly good class just at (120 m).
In this study, the Halder-Wagner method was used for an analysisX-ray lines of Tio2 nanoparticles. Where the software was used to calculate the FWHM and integral breath (β) to calculate the area under the curve for each of the lines of diffraction. After that, the general equation of the halder- Wagner method is applied to calculate the volume (D), strain (ε), stress (σ), and energy per unit(u). Volume (β). Where the value of the crystal volume was equal to (0.16149870 nm) and the strain was equal to (1.044126), stress (181.678 N / m2), and energy per unit volume (94.8474 J m-3).The results obtained from these methods were then compared with those obtained from each of the new paradigm of the HalderWagner method, the Shearer developm
... Show MoreCopper Telluride Thin films of thickness 700nm and 900nm, prepared thin films using thermal evaporation on cleaned Si substrates kept at 300K under the vacuum about (4x10-5 ) mbar. The XRD analysis and (AFM) measurements use to study structure properties. The sensitivity (S) of the fabricated sensors to NO2 and H2 was measured at room temperature. The experimental relationship between S and thickness of the sensitive film was investigated, and higher S values were recorded for thicker sensors. Results showed that the best sensitivity was attributed to the Cu2Te film of 900 nm thickness at the H2 gas.
The objective of this study was to assess the nutritional status of childs of nurseries in Baghdad city so that an early detection of malnutrition cases could be carried out. The results revealed that the daily consumption of food calories, protein, fat and carbohydrate were 1180.5 calories, 27.2gm, 38gm and 180gm, respectively, which were less than the RDA values and the percentages of these nutrients supplied by the food intake were 90.8, 83.7, 87.3 and 90.3%, respectively. It was also demonstrated that the highest percentages of stunting, underweight and wasting, which amounted to 32, 22.7 and 1.5%, respectively, were among those childs who obtained inadequate calories, while the percentages of the forementioned malnutrition cases amon
... Show MoreThe research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5
... Show More