Mature oil reservoirs surrounded with strong edge and bottom water drive aquifers experience pressure depletion and water coning/cresting. This laboratory research investigated the effects of bottom water drive and gas breakthrough on immiscible CO2-Assisted Gravity Drainage (CO2-AGD), focusing on substantial bottom water drive. The CO2-AGD method vertically separates the injected CO2 to formulate a gas cap and Oil. Visual experimental evaluation of CO2-AGD process performance was performed using a Hele-Shaw model. Water-wet sand was used for the experiments. The gas used for injection was pure CO2, and the “oleic” phase was n-decane with a negative spreading coefficient. The aqueous phase was deionized water. To evaluate the feasibility of the CO2-AGD process without any bottom water drives, it was first used. The experimental results demonstrated that existence of bottom water drive affected oil recoveries due to pressure support. Oil recovery before gas breakthrough increases proportionally with bottom water drive intensity. The gas breakthrough time recoveries for CO2-AGD1, CO2-AGD2, and CO2-AGD3 runs were 38.68%, 50.70%, and 60.85% of OOIP. The pressure gradient along the physical model decreases as bottom water drive intensity increases. The CO2-AGD approach delayed gas breakout by 72 min. As aquifer strength increases, gas breakthrough is delayed. In the three CO2-AGD runs and after breakthrough occurrence, the injector-producer pressure difference decreased due to the residual heads of oil and water columns above the horizontal well. As long as oil and water exist in the model, the pressure differential will not be zero, and the relative permeability and capillary trapping also control this phenomenon. Finally, it was demonstrated that there is a direct correlation between the strength of the aquifer and the oil recovery factor. The strength of the aquifer positively affects the oil recovery at breakthrough and the ultimate oil recovery.
Summary:This article discusses the topic of phraseological units with the names of wild animals in the Russian and Arabic languages in the aspect of their comparative semantic and cultural analysis, since a comparative analysis of the meanings of phraseological units of the Arabic and Russian languages, detection of coincidences and differences in the compared languages, is an important method for studying linguoculturology, since phraseological units represent a reflection of culture in the language
The relation between anemia and inflammatory immune response has lately had much attention. This research was conducted from October 2018 until April 2019, including (110) children below 12 years from both gender in some Hospitals, Primary Health care centers, Public Primary Schools and Kindergarten in Baghdad, Iraq. The objective of this study is to determine the possible correlation between iron deficiency anemia and inflammatory immune response among children infected with Entamoeba histolytica or Giardia lamblia. Blood samples were taken from all groups to measure hemoglobin level, serum iron, total iron binding capacity (TIBC), mean corpuscular volume (MCV), and mean corpuscular hemoglobin concentration
... Show Moreتصف هذه الدراسة تطوير تقنية سهلة ورخيصة ودقيقة وسريعة لقياس 4-اثيل فينول وتنطوي الطريقة الأولية على تحويل -3 نيترو انيلين إلى ملح ديازونيوم ثم التفاعل مع 4 - إثيل فينول في وسط قلوي.المعقد المتكون هو أصفر اللون وله امتصاص عند اعلى طول موجي عند 426 nm. ويتبع قانون بير في مدى خطي قدره 5-12 μg mL-1 مع معامل ارتباط قدره 0.994 وامتصاص مولاري 6.0024x10^3 L.mol-1.cm-1 وتم استُخدِام تقنية نقطة السحابة لقياس كميات قليلة جدا من الفينول باس
... Show MoreThe driving idea for the present work was to combine the effect of polyvinyl alcohol (PVA) as corrosion inhibitor with the distance between the anodic and cathodic elements of the galvanic cell, beside their area ratio, in scope of synergistic suppression of galvanic corrosion on Cu/Fe model couple, using weight loss method. The performance affecting galvanic corrosion process has been tested for three major factors affect the process:
1. Four PVA inhibitor concentrations were selected to be (0, 1000, 4000 and 7000 ppm) in simulated cooling water.
2. Two cathode: anode area ratios as 1:1 and 2.4:1.
3. Two distances apart cathode – anode as 3 and 7 cm.
Maximum corrosion inhibition achieved was 86% which indicates that increa
This work provides a historical overview of water storage tanks used for solar energy collection, with a focus on the impact of different geometric configurations on thermal performance and energy storage efficiency. The designs of cylindrical, spherical, rectangular and triangular tanks were reviewed to analyse their effects on thermal gradients, heat retention and energy storage capacity. Within the scope of nominal processes, the study primarily aimed to identify the factors influencing the choice of tank shape in terms of size, capacity and aspect ratio. Another key objective was to assess what enhances heat storage in the tank to improve thermal efficiency. Comparing cylindrical shapes to other shapes, such as spherical, rectan
... Show MoreThe distribution of chilled water flow rate in terminal unit is a major factor used to evaluate the performance of central air conditioning unit. In this work, a theoretical chilled water distribution in the terminal units has been studied to predict the optimum heat performance of terminal unit. The central Air-conditioning unit model consists of cooling/ heating coil (three units), chilled water source (chiller), three-way and two-way valve with bypass, piping network, and pump. The term of optimization in terminal unit ingredient has two categories, the first is the uniform of the water flow rate representing in statically permanents standard deviation (minimum value) and the second category is the maximum heat transfer rate fro
... Show MoreA study of irrigation water was conducted Baghdad city to find out extent of its pollution by some heavy metals (Pb, Cd, Ni, Co, CU, Cr, Zn and Fe). Water samples were collected randomly from different sources (river, well and stream). Results showed that the concentration of studied heavy metals were as follows: Lead between 0.43-11.75 mg L-1, Cadmium between 0.01-0.95 mg L-1, Nickel between 0.008-0.46 mg L-1, Cobalt between Nil - 0.185 mg L-1, Copper is between 0.326 - 1.58 mg L-1, Chromium is between Nil-0.068 mg L-1, Zinc 0.398-1.182 mg L-1, as for Iro
Occurrence the heavy metals in water is one of the most important concerns. may cause savior health problems. In this work we made an attempt to know the quantity of six heavy metals in groundwater in different locations of Baghdad city. Examinations were made on groundwater of the review region to assess the heavy metals. Groundwater samples were gathered and analyzed utilizing Atomic Absorption Spectrophotometer for their Manganese, Iron, Zinc, Cadmium, Copper and Lead content and their levels compared with World Health Organization (WHO) specified maximum contaminant level. In order to accomplish this, water samples were obtained from 10 randomly selected wells in the region, in February and August, 2016. The study showed that the ground
... Show More