Context: The ability of implant dentistry to be a successful alternative for edentulous patients has increased in the last decade. Clinical features such as osseointegration and stability, in addition to the endurance of the integration urged the researchers towards a better understanding of the design parameters that control long term success of the implants. It is therefore necessary to quantify the effect of changing implant design parameters on interface stress distribution within the maxilla bone. Methods and Materials: A 3D-finite element study was conducted to investigate the effect of changing implant shape parameters (implant body design and implant thread depth) on stress distribution while insertion of the implant in two different regions of maxilla bone (anterior (type III bone) and posterior (type IV bone)). A 3D-CAD geometry of implant-maxilla bone was created through importing digitally visualized CT skull images of a human adult, and then converted into a workable solid body through using a collection of engineering software. Tapered and cylindrical implant models with three different implant V-shaped thread depths (0.25 mm, 0.35 mm, 0.45 mm) were threaded into maxilla bone to investigate the design parameters effect on the final stress status. The proposed implant was of commercial dimensions of 10 mm length and 4 mm in diameter. A vertical static load of 250N was directly applied to the center of the suprastructure of the implant for each model. Results: Evaluations were performed for stress distribution patterns and maximum equivalent Von Mises (EQV) stresses for implants in two regions of maxilla bone under 250N vertical static loading. The obtained results throughout this work showed that, for all models, the highest stresses were located at the crestal cortical bone around the implant neck. The von-Mises stress distribution patterns at different models were similar and higher peak von-Mises stresses of cortical bone were seen in tapered implant body compared to cylinder body in all models. Conclusions: Within the restrictions of the current model, the results obtained can be applied clinically to select properly both implant thread depth and body shape design for a foreseeable success of implant therapy.
Multiplicative inverse in GF (2 m ) is a complex step in some important application such as Elliptic Curve Cryptography (ECC) and other applications. It operates by multiplying and squaring operation depending on the number of bits (m) in the field GF (2 m ). In this paper, a fast method is suggested to find inversion in GF (2 m ) using FPGA by reducing the number of multiplication operations in the Fermat's Theorem and transferring the squaring into a fast method to find exponentiation to (2 k ). In the proposed algorithm, the multiplicative inverse in GF(2 m ) is achieved by number of multiplications depending on log 2 (m) and each exponentiation is operates in a single clock cycle by generating a reduction matrix for high power of two ex
... Show MoreWe studied the effect of certain environmental conditions for removing heavy metal elements from contaminated aqueous solutions (Cd, Cu, Pb, Fe, Zn, Ni, Cr) using the bacterium Bacillus subtilis to appoint the optimal conditions for removal ,The best optimum temperature range for two isolate was 30-35○C while the hydrogen number for the maximum mineral removal range was 6-7. The best primary mineral removal was 100 mg/L, while the maximum removal for all minerals was obtained after 6 hrs of Cu element time and the maximum removal efficiency was obtained after 24 hrs of Cu element. The results have proved that the best aeration for maximum removal was obtained at rotation speed of 150 rpm/minute. Inoculums of 5ml/100ml which contained 1
... Show MoreExperimental programs based test results has been used as a means to find out the response of individual elements of structure. In the present study involves investigated behavior of five reinforced concrete deep beams of dimension (length 1200 x height 300 x width150mm) under two points concentrated load with shear span to depth ratio of (1.52), four of these beams with hallow core and
retrofit with carbon fiber reinforced polymer CFRP (with single or double or sides Strips). Two shapes of hallow are investigated (circle and square section) to evaluated the response of beams in case experimental behavior. Test on simply supported beam was performed in the laboratory & loaddeflection, strain of concrete data and crack pattern of
This study presents a detailed morphology and taxonomic study of Polysiphonia subtilissima collected from Abdul Rehman Goth, Karachi coast, Pakistan. Polysiphonia is a filamentous heterotrichous red algae, characterized by its branching structures and attachment mechanisms. P. subtilissima is notable for its broad salinity tolerance and wide distribution across marine and freshwater ecosystems. This research provides an in-depth examination of the internal and external structures of P. subtilissima, contributing to its systematic study and documenting its first recorded occurrence in Pakistani coastal areas, bordering the northern Arabian Sea. The findings enhance the understanding of the species taxonomy and its ecological role in
... Show More
Abstract:
We can notice cluster data in social, health and behavioral sciences, so this type of data have a link between its observations and we can express these clusters through the relationship between measurements on units within the same group.
In this research, I estimate the reliability function of cluster function by using the seemingly unrelate
... Show MoreElectrochemical oxidation in the presence of sodium chloride used for removal of phenol and any other organic by products formed during the electrolysis by using MnO2/graphite electrode. The performance of the electrode was evaluated in terms fraction of phenol and the formed organic by products removed during the electrolysis process. The results showed that the electrochemical oxidation process was very effective in the removal of phenol and the other organics, where the removal percentage of phenol was 97.33%, and the final value of TOC was 6.985 ppm after 4 hours and by using a speed of rotation of the MnO2 electrode equal to 200 rpm.
BACKGROUND: The humeral shaft fractures have a good rate of union, despite this fact, still there is a significant rate of nonunion after nonoperative treatment and more often after operative treatment. AIM: The aim of the study is to evaluate the autogenous onlay graft with compression plate for treatment of persistent humeral shaft non-union with failed previous surgery both radiological and functional outcome. MATERIALS AND METHODS: A prospective study on twenty patients having persistent aseptic non-union age between 20 and 60 years old, after failed surgical treatment of fractures humeral shaft in Al-Zahra teaching and Al-Kindy teaching hospitals, while infected nonunion, diabetes mellitus, secondary metastasis, smoking, a
... Show MoreThe accurate extracting, studying, and analyzing of drainage basin morphometric aspects is important for the accurate determination of environmental factors that formed them, such as climate, tectonic activity, region lithology, and land covering vegetation.
This work was divided into three stages; the 1st stage was delineation of the Al-Abiadh basin borders using a new approach that depends on three-dimensional modeling of the studied region and a drainage network pattern extraction using (Shuttle Radar Topographic Mission) data, the 2nd was the classification of the Al-Abiadh basin streams according to their shape and widenings, and the 3rd was ex
... Show More