The purpose of this paper is to evaluate neuromuscular fatigue among elite basketball players in the Iraqi Basketball League using surface electromyography (sEMG) with the Ultium EMG device and the MR3.18 program, and using the Wavelet analysis application with the Continuous Wavelet Transform (CWT) method. The research sample included six advanced players from the Iraqi Elite League, aged (21.50 ±3.67) years, with a body mass of (80.50 ±11.71) kg, and a height of (189.00 ±7.75) cm. The research sample underwent a physical skill-exertion protocol that simulated the actual playing requirements of basketball, during which the electrical activity of the six selected muscles involved in performing the skill of shooting long-range three-point shots from outside the arc in the upper and lower limbs was measured. The anterior deltoid, the lateral triceps, the extensor carpi radialis, the flexor carpi radialis, the rectus femoris, and the lateral gastrocnemius represented these muscles. Forward fatigue was assessed in the three-point long-range shootingskill experienced before and after effort from low (15–45 Hz), through moderate (45–95 Hz) to high (95–400 Hz) frequency ranges. It was found that only one significant difference occurred in the rectus femoris muscle at high frequencies (p = 0.02, Cohen’s dz = 1.48), indicating significant neuromuscular fatigue associated with the muscle's high functional role in jumping, acceleration, deceleration, and while changing direction. The other muscles, however, did notdemonstrate statistically significant differences, although a small (to moderate) size of the traces was found, which could indicate that there has been reorganization of the neuromuscular activation strategy to compensate for performance. These results verify that CWT analysis is a sensitive and valid tool for dynamic, non-stationary, or cyclic sports activities, such as basketball, to estimate neuromuscular fatigue, and that it enhances understanding of task-specific muscle responses compared with other conventional spectral methods.
The gamma dose rates and specific activity of 137Cs, 60Co and 40K in
samples of soil taken from places near the landfill radiation at Al-
Tuwaitha site were measured using a portable NaI(Tl) detector. The
results of gamma dose rates in samples were ranged from 52.6
nGy.h-1 to 131nGy.h-1. Then the specific activity of 137Cs, 60Co and
40K in soil were determined using high pure germanium (HPGe)
detector. The specific activities were varied from 1.9 to 115500 Bq.
kg-1 for 137Cs, from 6.37 to 616.5 Bq. kg-1 for 60Co, and from 3 to
839.5 Bq. kg-1 for 40K. The corresponding health risk for the annual
effective dose equivalent varied from 1.85×10-14 to 15.7mSv/y. The
results were compared with various internationa
B Saleem, H Alwan, L Khalid, Journal of Engineering, 2011 - Cited by 2
This paper compares between the direct and indirect georeferencing techniques in Photogrammetry bases on a simulation model. A flight plan is designed which consists of three strips with nine overlapped images for each strip by a (Canon 500D) digital camera with a resolution of 15 Mega Pixels.
The triangulation computations are carried out by using (ERDAS LPS) software, and the direct measurements are taken directly on the simulated model to substitute using GPS/INS in real case. Two computational tests have been implemented to evaluate the positional accuracy for the whole model and the Root Mean Square Error (RMSE) relating to (30) check points show that th
... Show MoreAbstract
The aim of the research is to demonstrate the role of uncertainty in adopting the general requirements for the strategic environmental assessment of service departments in Babil Governorate and the Environment Department. By focusing on a range of environmental problems, despite the efforts exerted to deal with the environme
... Show MoreThe first aim of this paper was to evaluate the push-out bond strength of the gutta-percha coating of Thermafil and GuttaCore and compare it with that of gutta-percha used to coat an experimental hydroxyapatite/polyethylene (HA/PE) obturator. The second aim was to assess the thickness of gutta-percha around the carriers of GuttaCore and HA/PE obturators using microcomputed tomography (