Preferred Language
Articles
/
ghYNTocBVTCNdQwCkEOI
The effect of osseodensification on implant stability and bone density: A prospective observational study
...Show More Authors

Background: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was considered statistically significant. Results: Of the 46 implants, 43 were osseointegrated making the early survival of the implants 93.5%. There was a significant increase in bone density postoperatively; 337.6 ±182.9 compared to 265.3 ±173.9 Hounsfield units preoperatively. The primary implant stability was -2.7 ± 2.13 Periotest values (PTV), at the 6th week it decreased significantly (p<0.0001) to become 0.7 (± 4) PTV, and at the 12th week (secondary stability) it increased significantly (p<0.0001) to become -2.1 (± 2.8) PTV. The difference between primary and secondary stability was statistically non-significant (p=0.0814). Conclusions: Osseodensification resulted in high primary stability and increased peri-implant bone density but it did not prevent the implant stability drop during the first 6 weeks after insertion of implants. Key words:Osseodensification, implant stability, low-density bone.

Scopus Crossref
View Publication
Publication Date
Sun Jul 01 2018
Journal Name
Vacuum
Stability, electronic and vibrational properties of GaAlN wurtzoid molecules and nanocrystals: A DFT study
...Show More Authors

View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu Nov 22 2018
Journal Name
Al-khwarizmi Engineering Journal
Experimental and Finite Elements Analysis Study of Warming Effect on Deboned Force for Embedded NiTinol Wire into Linear Low Density Polyethylene
...Show More Authors

This study presents the debonding propagation in single NiTi wire shape memory alloy into linear low-density polyethylene matrix composite the study of using the pull-out test. The aim of this study is to investigate the pull-out tests to check the interfacial strength of the polymer composite in two cases, with activation NiTinol wire and without activation. In this study, shape memory alloy NiTinol wire 2 mm diameter and linear fully annealed straight shape were used. The study involved experimental and finite element analysis and eventually comparison between them. This pull-out test is considered a substantial test because its results have a relation with behavior of smart composite materials. The pull-out test was carried out by a u

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Sep 26 2025
Journal Name
Journal Of Baghdad College Of Dentistry
In vivo immunohistochemical investigation of the effect of the topical application of growth hormone on the osseointegration of cpTi implant
...Show More Authors

Background: Dental implants are a suitable option for the replacement of some or all missing teeth. The successful insertion of a biocompatible material into living tissue with little to no evidence of rejection has revolutionized medicine and dentistry. An increase in bone response was observed with local administration of growth hormone around dental implants. Growth hormone may act as a bone stimulant in the placement of endosseous dental implants and enhances osseointegration. The aim of the study was to evaluate immunohistochemically the effect of the topical application of growth hormone on the osseointegration of cpTi implant. Materials and Methods: Eighty titanium screw implants were inserted in the tibia of the forty adult rabbits.

... Show More
View Publication Preview PDF
Publication Date
Wed Oct 02 2024
Journal Name
International Development Planning Review
A COMPARATIVE STUDY OF THE AMOUNT OF FORCE EXERTED ON THE GROUND AND THE TIME OF PROPULSION IN THE VERTICAL AND HORIZONTAL JUMPING TESTS FROM STABILITY USING A FOOT SCAN DEVICE
...Show More Authors

Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Fiber Laser Effect on Bond Strength of Titanium implant abutment to Resin Cement
...Show More Authors

Aim: surface modification of titanium using fiber laser 1064 nm to enhance the bond strength to resin cement. Material and Methods: thirty titanium discs of 0.6 cm x 0.3 cm (diameter and thickness respectively) were categorized after preparation into three groups (n=10) as follows: control group with no surface treatment and two test groups were treated with fiber laser after estimation the appropriate parameters in the pilot study which are 81 ns pulse duration, 30,000 Hz frequency, 50 µm spot size and 10,000 mm/s scanning speed and different average power values (10 W and 20 W) depending on the tested group. Titanium discs surface characterization was performed by scanning electron microscope (SEM), a

... Show More
View Publication Preview PDF
Publication Date
Fri Apr 30 2021
Journal Name
Al-kindy College Medical Journal
Slump Test versus Straight Leg Raise Test in the Diagnosing of Lumbar Disc Herniation: A Prospective Comparative Study
...Show More Authors

Background: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation.

Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation.

Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pai

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Fri Apr 30 2021
Journal Name
Al-kindy College Medical Journal
Slump Test versus Straight Leg Raise Test in the Diagnosing of Lumbar Disc Herniation: A Prospective Comparative Study
...Show More Authors

Background: The clinical examination is one of the best suitable methods for diagnosis of low backache. Backache is one disease that the signs, clinical examination finding, and the results on imaging modalities not always related. The straight leg raising (SLR) and slump tests, can be used for diagnosis of lumber disc herniation. Objectives: To compare the result of the slump test and SLR test in the diagnosis of lumber disc herniation. Subjects and Methods: A prospective comparative study conducts on 280 patients in Al-Kindy teaching and private clinics complaints of backache, aging between 18-70 years old with acute or recurrent backache, sciatica pain, or low back and sciatica pain for last 12 weeks, while patients

... Show More
Preview PDF
Crossref (2)
Crossref
Publication Date
Sat May 01 2021
Journal Name
Journal Of Physics: Conference Series
Modeling the Effect of Particle Packing Density for Sintering
...Show More Authors
Abstract<p>This research studies the effect of particle packing density on sintering TiO<sub>2</sub> microstructure. Sintering experiment was conducted on compacts involving of monodisperse spherical TiO2 particles. The experimental results are modeled using L<sup>2</sup>-Regression technique in studing the effect of two theoretical values of 55% and 69% of initial packing densities. The mathematical simulation shows that the lower values of density compacts sintered fast to theoretical density and this reflects that particle packing density improved densification rate because of the competing influence of grain growth at higher values of densities.</p>
View Publication
Scopus (3)
Crossref (2)
Scopus Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of Grain and Calcinations Kaolin Additives on Some Mechanical and Physical properties on Low Density Polyethylene Composites
...Show More Authors

In this work, a composite material was prepared from Low-density polyethylene (LDPE) with different weight percent of grain and calcinations kaolin at temperature of (850oC) using single screw extruder and a mixing machine operated at a temperature between (190-200oC). Some of mechanical and physical properties such as tensile strength, tensile strength at break, Young modulus, and elongation at break, shore hardness and water absorption were determined at different weight fraction of filler (0, 2, 7, 10 and 15%). It was found that the addition of filler increases the modulus of elasticity, elongation at break, shore hardness and impact strength; on other hand, it decreases the tensile strength and tensile strength

... Show More
View Publication Preview PDF
Publication Date
Tue May 30 2023
Journal Name
Gsc Biological And Pharmaceutical Sciences
Anatomical study of the 3rd metacarpal bone of some mammals
...Show More Authors

The current study included the anatomical structure of the metatarsal bone in sheep in terms of the traditional structural description of the bone, as it was found that the metatarsal bone in the fore and hind limbs of adult sheep had no visible differences between it and animals, especially ruminants. The metacarpal \tarsal bone No. 3 was cylindrical in shape, with the presence of the metacarpal \tarsal bones 2 and 4 declines, articulated from the proximal end with the metacarpal and metatarsal bones whereas from the distal part with the fetlock joint and the first phalanx bone. The aim of the study is to determine whether the environment and its changes in Iraq have affected the animals and their bones in terms of length, thicknes

... Show More
View Publication
Crossref