Background Obstructing dentinal tubules is a valuable approach for managing dentin hypersensitivity. Although various agents promote dentin remineralization, direct comparisons between theobromine, bioactive glass (BAG), and nano-hydroxyapatite (Nano-HAP) under simulated oral conditions remain limited. To fill this gap, this in vitro study aimed to evaluate and compare the effectiveness of these three treatments on exposed cervical dentin. The assessment focused on their chemical, morphological, and mechanical effects on dentin. Materials and methods Forty-eight human dentin slabs were obtained from the cervical portions of twelve sound premolar teeth. Baseline Raman spectroscopy and VMH tests were done to exclude outliers. All specimens were treated with 6 % citric acid (pH 2.0) for 2 min to remove the smear layer. They randomly assigned to four groups (n = 12): artificial saliva (AS), theobromine, BAG, and Nano-HAP. Evaluations were conducted using Raman spectroscopy (phosphate peak intensity at 960cm−1), Vickers microhardness testing (VMH), and morphological assessment under scanning electron microscopy (SEM). Results Theobromine, BAG, and nano-HAP groups demonstrated a statistically significant increase in Raman phosphate peak intensity (960cm−1) and Vickers microhardness values (p < 0.05), indicating surface remineralization. In contrast, the artificial saliva group exhibited a significant decrease in phosphate peak intensity and microhardness values (p < 0.05). Conclusion All tested agents significantly enhanced the Raman phosphate peaks and microhardness values compared to the control. Nano-HAP showed the highest potential for promoting the remineralization of exposed dentin surfaces. Within the study's limitations, it can be concluded that theobromine, BAG, and nano-HAP are effective in occluding dentinal tubules.
Background:The demand for esthetic orthodontic appliances is increasing so that the esthetic orthodontic archwires were introduced. This in vitro study was designed to evaluate the surface roughness offiber-reinforced polymer composite (FRPC) archwires compared to coated nickel-titanium (NiTi) archwires immersed in artificial saliva. Materials and Methods:Three types of esthetic orthodontic archwires were used: FRPC (Dentaurum), Teflon coated NiTi (Dentaurum) and epoxy coated NiTi (Orthotechnology). They were round (0.018 inch) in cross section and cut into pieces of 15 mm in length.Forty pieces from each type were divided into four groups; one group was left at a dry condition and the other three groups were immersed in artificial saliva (
... Show MoreThis study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were th
... Show MoreThe experiment was conducted to study the effect of sodium chloride (NaCl) at the concentrations of 0.0, 0.5, 1.0 and 1.5% on the callus cells. The Iraq wheat variety was grown in vitro for the purpose of knowing the effect of salt stress on some indicators and cellular components of callus by using a randomized complete design, at the laboratories of tissue culture propagation date palm unit in the College of Agriculture / University of Kufa during the period 2014-2015. Fresh and dry weight, the rate of absolute growth, percentage of dry matter of callus, content of the callus cells of proline, total soluble carbohydrates, sodium and potassium ions, effectiveness of the enzymes catalase and peroxidase study shock salt proteins in callus we
... Show MoreThe purpose of this study is to investigate the histopathological response of dentinopulpal
response of human teeth to the Er: YAG laser cavity preparation in comparison with the conventional
class I cavity preparation. Thirty five sound human upper and lower first premolar teeth which were
needed to be extracted for orthodontic purposes were used in the study. Regarding to the method of
cavity preparation, the teeth were grouped into three groups; Group1; Control group which consists of
seven sound teeth without cavity preparation, Group2; Conventional cavity preparation group and group
3; Er: YAG laser cavity preparation group. Each of Group2 and3 consists of fourteen teeth that is
subdivided into: A. 7teeth that e
The results of the current study showed that the liver of H. javanicus appeared as large lobulated organ divided into six distinct lobes, that filled the cranial region and little extended to the middle region of abdominal cavity. On the other hand, liver of S. carolinensis laid against the diaphragm, occupied the cranial region of the abdominal cavity and consisted of five lobes. The liver is surrounded with a thin capsule of dense regular collagenous connective tissue and few numbers of smooth muscles fibers can be seen in the capsule that covered the squirrel liver. The liver parenchyma divided into a large number of interconnected hepatic lobules marked only by the abundant amount of connective tissue bordered the triads, and within the
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the effect of preheating microleakage among three different filler size composites which include Filtektm Z250 micro hybrid, Z250xt Nano hybrid and nanocomposite Z350xt. in Class II cavity preparation .
Materials and methods: sixty maxillary first premolars were prepared with class II cavities. Samples were divided into three groups according to material used group A (FiltekZ250 micro hybrid). Group B(Z250xt Nano hybrid). Group C (nanocomposite Z350xt)and each group divided into two subgroups of ten teeth according to temperature of composite:
... Show MoreThis research presents an experimental investigation on the influence of metakaolin replacement percentage upon some properties of different concrete types. Three types of concrete were adopted (self- compacted concrete, high performance concrete and reactive powder concrete) all of high sulphate (SO3) percentage from the fine aggregate weight, 0.75%. Three percentages of metakaolin replacement were selected to be studied (5, 7 and 10) %. Three types of concrete properties (compressive, flexural and splitting tensile strength) were adopted to achieve better understanding for the influence of adding metakaolin.. The output results indicated that the percentage of metakaolin had a different level of positive effect on the compressive strength
... Show MoreBackground: The marginal seal is essential for sealant success because penetration of bacteria under the sealant might allow caries onset or progression. The aim of the present study was to estimate and compare the microleakage of pit and fissure sealant after various methods of occlusal surface preparation. Materials and methods: Thirty non-carious premolars extracted for orthodontic reasons were equally divided into three groups. In group one, occlusal fissures were opened with round carbide bur, in group two, occlusal surfaces of the teeth were cleaned with a dry pointed bristle brush and samples of group three were cleaned with a slurry of fine flour of pumice in water using rubber cup. Then fissures of all teeth were etched using 35% p
... Show MoreBackground: Laser is a novel physical therapy technique used to treat various conditions, including wound healing, inhibition of bacterial growth, and postoperative wounds. High-power pulsed alexandrite laser therapy is one of the most prevalent forms of laser therapy, which is a noninvasive method for treating various pathological conditions, thereby enhancing functional capacities and quality of life. It is a modern medical and physiotherapeutic technology. Generally, the Alexandrite laser emits infrared light with a wavelength of 755 nm, allowing it to propagate and penetrate tissues. Objective: This study focused on the application of a high-power pulsed alexandrite laser in vitro to evaluate the effect of a pulsed alexandrite l
... Show More