Preferred Language
Articles
/
gRfTs5IBVTCNdQwCxr53
Design and Implementation of Appliance Controller using Traditional or Smart Phone
...Show More Authors

Mobile phones are widely used nowadays, for different application such as wireless control and monitoring due to its availability and ease of use. The implemented system is based on "global system mobile (GSM)" network by using "short message service (SMS)". The design mainly contains a GSM modem and interfacing unit circuit with microcontrollers. This system could control up to eight different electrical devices such as light, Air conditioner, washing machine and many more applications which needed in daily life in different area (House, Office, or factory, etc.). The control is done by sending a specific SMS messages from traditional or smart phone. The controlling devices are restricted to a pre-defined phone number and are set in the software of the receiver. Also feedback status of eight devices can be requested in designed system. The designed receiver recovers syntax errors, like additional spaces, special symbols, and repeated letters.

View Publication
Publication Date
Wed Jan 01 2020
Journal Name
Periodicals Of Engineering And Natural Sciences
Comparing traditional estimators and the estimators of (PSO) algorithm for some growth models of gross domestic product in Iraq
...Show More Authors

View Publication
Scopus
Publication Date
Fri Jan 08 2010
Journal Name
Al-kindy College Medical Journal
Maternal and fetal outcomes in emergency versus elective two or more previous cesarean deliveries
...Show More Authors

Publication Date
Wed Jun 30 2010
Journal Name
Al-kindy College Medical Journal
MATERNAL AND FETAL OUTCOMES IN EMERGENCY VERSUS ELECTIVE TWO OR MORE PREVIOUS CAESAREAN DELIVERIES
...Show More Authors

Background: Women with previous two or
more caesarean deliveries are usually
managed by elective cesarean section to avoid
the possible risks of labor.
Objective: To compare the relative risks of
maternal and fetal outcomes in emergency
versus elective previous two or more
caesarean deliveries
Design: Randomized prospective clinical
study
Setting: Al-Elweya Maternity Teaching
Hospital, from 1st of March to 31st of
September 2008.
Methods: The study groups, those who had
previous two or more caesarean deliveries,
were included from the hospital admissions.
The 1st group (102 women) presented in labor
and was managed by caesarean delivery as
soon as it was possible. The second group (7

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Journal Of Research In Medical Sciences
Procalcitonin levels and other biochemical parameters in patients with or without diabetic foot complications
...Show More Authors

View Publication
Scopus (26)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Thu Jun 01 2017
Journal Name
Journal Of Economics And Administrative Sciences
Controller work specificity and their impact on performance (Applied Study in the financial oversight bodies)
...Show More Authors

The research aims to a statement of specificity of the Controller of (academic achievement, specialty, job title, length of service, Gender) and its impact on performance, Through a proposed appraisal form includes three main axes and each axis including several specialized elements in the supervisory work in form (check list). as is the importance of research to enable officials of oversight bodies financial identify and diagnose performance Controller through what has this observer of the process of scientific properties when performing supervisory work. Be summarized problem of the research that the lack of regulatory institution with the Controller interesting in terms of the necessary characteristics and requirements and inv

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Mechanical Engineering Research And Developments
Development of natural convection heat transfer in heat sink using a new fin design
...Show More Authors

Scopus (2)
Scopus
Publication Date
Tue Dec 01 2020
Journal Name
Propulsion And Power Research
Heat transfer enhancement from heat sources using optimal design of combined fins heat-sinks
...Show More Authors

View Publication
Scopus (8)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2011
Journal Name
Iraqi Journal Of Physics
Design of Achromatic Combined Quadrupole Lens Using the Modified Bell-Shaped Field Distribution Model
...Show More Authors

The optimization calculations are made to find the optimum properties of combined quadrupole lens consist of electrostatic and magnetic lenses to produce achromatic lens. The modified bell-shaped model is used and the calculation is made by solving the equation of motion and finding the transfer matrices in convergence and divergence planes, these matrices are used to find the properties of lens as the magnification and aberrations coefficients. To find the optimum values of chromatic and spherical aberrations coefficients, the effect of both the excitation parameter of the lens (n) and the effective length of the lens into account as effective parameters in the optimization processing

View Publication Preview PDF
Publication Date
Tue Dec 01 2020
Journal Name
Sn Applied Sciences
Regressor-free adaptive vibration control of constrained smart beams with axial stretching
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
Improve the Performance of PID Controller by Two Algorithms for Controlling the DC Servo Motor
...Show More Authors

The paper uses the Direct Synthesis (DS) method for tuning the Proportional Integral Derivative (PID) controller for controlling the DC servo motor. Two algorithms are presented for enhancing the performance of the suggested PID controller. These algorithms are Back-Propagation Neural Network and Particle Swarm Optimization (PSO). The performance and characteristics of DC servo motor are explained. The simulation results that obtained by using Matlab program show that the steady state error is eliminated with shorter adjusted time when using these algorithms with PID controller. A comparative between the two algorithms are described in this paper to show their effectiveness, which is found that the PSO algorithm gives be

... Show More
View Publication Preview PDF