Abstract: Residual ridge resorption is chronic, progressive, irreversible and cumulative condition associated with teeth loss. Management of a residual ridge with severe resorption to fulfill the patient’s esthetic and functional requirements is quite difficult for the practitioner and also in the construction of an acceptable appliance. As the height of the edentulous ridge reduces the mandibular denture will be improperly function. Severe resorption of the mandibular alveolar ridge may cause instability and discomfort of the convention acrylic resin denture. Dealing with this condition requires clinical skills and knowledge. Treating the severely resorbed mandibular ridge is a challenging effort for prosthodontics. This research presents a case report on neutral zone impression technique used for treating a completely edentulous patient with resorbed ridges, in addition to using four dental implants in order to get the benefits of both occlusal harmony from the neutral zone which located the teeth in it and the support, retention from implants in bone. The use of combination of a neutral zone impression technique and the implant supported over denture for the treatment of severely resorbed mandibular ridge result in patient satisfied with the enhancement in denture retention, stability, and support.
The primary objective of root canal therapy is adequate biomechanical preparation of root canal system followed by 3D obturation.in clinics we are encountered with several anatomical variations, which we need to manage efficiently. One of the major factors responsible for failure of root canal therapy is missed canals. Recent technological advances have given the clinician opportunity to identify anatomical variations and treat them to satisfaction.
One of the critical factors for dental implant success is accurate clinical and radiological assessment. Cone-beam computed tomography systems (CBCT) allow surgeons to determine the quality and quantity before surgery, aiding in treatment planning. This study highlights the importance of such an assessment Materials and Methods A total of 40 patients were referred to CBCT scanning for pre-dental implant assessment in the Oral and Maxillofacial Radiology department at Al-Shaheed Gazi Al Hariri Hospital from 2021 to 2022. The patients were between 18 and 50 years old. All data were analyzed with on-demand 3D software (Kavo OP 3D: Cone Beam 3D imaging Germany). Results: Regarding the ridge shape: In the upper anterior and posterior regions, th
... Show MoreStructure type and disorder have become important questions in catalyst design, with the most active catalysts often noted to be “disordered” or “amorphous” in nature. To quantify the effects of disorder and structure type systematically, a test set of manganese(III,IV) oxides was developed and their reactivity as oxidants and catalysts tested against three substrates: methylene blue, hydrogen peroxide, and water. We find that disorder destabilizes the materialsthermodynamically, making them stronger chemical oxidantsbut not necessarily better catalysts. For the disproportionation of H2O2 and the oxidative decomposition of methylene blue, MnOx-mediated direct oxidation competes with catalytically mediated oxidation, making the most
... Show MoreResumo Objetivos: determinar a eficiência e segurança de três regimes de misoprostol para interrupção da gravidez no segundo trimestre em indivíduos com duas ou mais cicatrizes de cesariana. Métodos: um estudo transversal incluiu 100 gestantes entre 13ª e 26ª semanas de gestação com duas cesarianas (CEs) anteriores que foram agendadas para interrupção da gravidez com uso de misoprostol. Os pacientes foram convenientemente designados para regimes de 100 µg/3 horas, 200 µg/3 horas ou 400 µg/3 horas. O desfecho primário foi o tempo para o aborto, os desfechos secundários foram efeitos colaterais e complicações. Resultados: foi encontrada associação significativa entre o número de cesáreas anteriores e o maior
... Show MoreBackground: It has been well known that the success of mandibular implant- retained overdenture heavily depends on initial stability, retention and long term osseointegration this is might be due to optimal stresses distribution in surrounding bones. Types of mandibular implant- retained overdenture anchorage system and number of dental implants play an important role in stresses distribution at the implant-bone interface. It is necessary to keep the stresses below the physiologic tolerance level of the bone .since. And it is difficult to measure these stresses around bone in vivo. In the present study, finite element analysis used to study the stresses distribution around dental implant supporting Mandible implant retained overdenture Mate
... Show MoreBackground: This study aimed to assess the effect of tooth shape ratio on mandibular incisor arrangement. Materials and methods: The sample included dental casts of some dental students and orthodontic patients having Class I dental and skeletal patterns with normal occlusion and severe crowding. The sample was divided into two groups according to the severity of crowding into: group I had Class I normal occlusion with mild or no crowded mandibular dentition and group II had Class I malocclusion with severe crowded mandibular dentition. Each group comprising of 40 subjects (20 males and 20 females). The mesio-distal and facio-lingual crown diameters were measured manually for each cast using modified vernier caliper gauge. Descriptive sta
... Show MoreBackground: Consideration of mandibular third molar is important from orthodontic perspective due to several factors such as, lower anterior arch crowding, relapse in lower anterior region, interference with uprighting of mandibular first and second molars during anchorage preparation and molar distalization. The aims of this study were to assess of gender differences in the mandibular third molar position and compare and evaluate whether there is any differences in the results provided by CT scan and lateral reconstructed radiograph. Materials and Methods: The sample of present study consisted of 39 patients (18 males and 21 females) with age range 11-15 years. CT images for patients who were attending at Al Suwayra General Hospital/the C
... Show MoreWearable sensors are a revolutionary tool in agriculture because they collect accurate data on plant environmental conditions that affect plant growth in real-time. Moreover, this technology is crucial in increasing agricultural sustainability and productivity by improving irrigation strategies and water resource management. This review examines the role of wearable sensors in measuring plant water content, leaf and air humidity, stem flow, plant and air temperature, light, and soil moisture sensors. Wearable sensors are designed to monitor various plant physiological parameters in real-time. These data, obtained through wearable sensors, provide information on plant water use and physiology, making our agricultural choices more informed an
... Show More