Preferred Language
Articles
/
fhiLZ5UBVTCNdQwCbS0l
Pulse transmission time and amplitude of digital pulse wave determined by fingertip plethysmography as a surrogate marker of brachial artery flowmediated dilatation
...Show More Authors

Objectives: To assess the changes in blood vessel stiffness and digital pulse wave amplitude because of flowmediateddilatation, and to explore how these two variables change when endothelial dysfunction isexperimentally induced.Method: The experimental study was conducted at the departments of physiology at the College of Medicine,Mustansiriyah University, and the College of Medicine, Al-Iraqia University, Baghdad, Iraq, from October 14, 2021, toMay 31, 2022, and comprised healthy young males who were subjected to the flow-mediated dilatation techniqueon the left brachial artery. Pulse transit time and the amplitude of the digital pulse wave were measured duringreactive hyperaemia for 2.5 minutes from the left middle finger using a piezoelectric pressure sensor and asimultaneous Lead I electrocardiogram. Endothelial dysfunction (ED) was induced by oscillatory and retrogradeshear rates. The correlation between variables was calculated in Excel running on the Windows operating system.Results: There were 10 second-year medical students with mean age 22±0 years and mean body mass index25.7±4.8kg/m2. During reactive hyperaemia, pulse transit time was significantly increased by 3-5% in both normalendothelium and experimentally induced endothelial dysfunction relative to the pre-occluded artery, and thedifference was not significant (p>0.05). Digital pulse wave amplitude increased significantly in normal endotheliumrelative to the pre-occluded artery (p<0.05), but not in experimentally-induced endothelial dysfunction (p>0.05).Conclusion: The pulse transit time and digital pulse wave amplitudes of the photo plethysmography signal may beused to detect changes in vessel wall diameter and tone throughout the reactive hyperaemia process. Digital pulsewave amplitude was better able to detect experimentally-induced endothelial dysfunction, as assessed by the flowmediateddilatation protocol, than pulse transit time.Key Words: Hyperemia, Brachial Artery, Dilatation, Plethysmography, Electrocardiography, Pulse Wave,Endothelium, Running

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
International Journal On Interactive Design And Manufacturing (ijidem)
A real-time automated sorting of robotic vision system based on the interactive design approach
...Show More Authors

View Publication
Scopus (42)
Crossref (33)
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Medical Journal Of Babylon
Prevalence of coronary artery disease in patients with left bundle branch block and its association with risk factors hypertension and diabetes mellitus
...Show More Authors
Abstract<sec> <title>Background:

Left bundle branch block (LBBB) is a common finding in electrocardiography, there are many causes of LBBB.

Objectives:

The aim of this study is to discuss the true prevalence of coronary artery disease (CAD) in patients with LBBB and associated risk factors in the form of hypertension and diabetes mellitus.

Materials and Methods:

Patients with LBBB were admitted to the Iraqi heart center for cardiac disea

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jun 21 2023
Journal Name
Journal Of Electrochemical Science And Engineering
Phenol removal by electro-Fenton process using a 3D electrode with iron foam as particles and carbon fibre modified with graphene
...Show More Authors

The 3D electro-Fenton technique is, due to its high efficiency, one of the technologies suggested to eliminate organic pollutants in wastewater. The type of particle electrode used in the 3D electro-Fenton process is one of the most crucial variables because of its effect on the formation of reactive species and the source of iron ions. The electrolytic cell in the current study consisted of graphite as an anode, carbon fiber (CF) modified with graphene as a cathode, and iron foam particles as a third electrode. A response surface methodology (RSM) approach was used to optimize the 3D electro-Fenton process. The RSM results revealed that the quadratic model has a high R2 of 99.05 %. At 4 g L-1 iron foam particles, time of 5 h, and

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sat Oct 15 2005
Journal Name
Journal Of Palestine Ahliya University For Research And Studies
Digital Stress Among University Students in Light of Certain Variables
...Show More Authors

This study aimed to measure digital stress among students at the University of Baghdad and to identify differences in digital stress based on gender (male–female), academic level (first–fourth year), and field of study (scientific–humanities). The study sample consisted of 200 students from the University of Baghdad. The "Digital Stress" scale, developed by the researcher specifically for this study, was applied, and the descriptive-analytical method was adopted. After administering the scale and analyzing the results using appropriate statistical methods, the findings indicated that university students experience a high level of digital stress, while no statistically significant differences were found in digital stress accord

... Show More
View Publication
Crossref
Publication Date
Sun Mar 12 2017
Journal Name
Al-academy
Reality design Arabic letters for the purposes of digital programming
...Show More Authors

Arabic calligraphy has great importance in the printing designs that are often on the written character-based to perform functional goals and to achieve some of the aesthetic values ​​in design work, has led major developments in the field of computer manufacturing and design software for the design and layout to increase to deal with the programmed character for the purposes of typesetting has confronted this Find the Arab character programmed for the purposes of typesetting for the detection of the most important design interventions that underwent the Arabic letter written to turn it into a programmed image intended for the purposes of the printing and typesetting has been addressed in the context of which the theoretical types of

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Aug 15 2023
Journal Name
Al-academy
The effectiveness of artificial intelligence in contemporary digital graphic design
...Show More Authors

In our world, technological development has become inherent in all walks of life and is characterized by its speed in performance and uses. This development required the emergence of new technologies that represent a future revolution for a fourth industrial revolution in various fields, which contributed to finding many alternatives and innovative technical solutions that shortened time and space in terms of making Machines are smarter, more accurate, and faster in accomplishing the tasks intended for them, and we find the emergence of what is called artificial intelligence (artificial intelligence), which is the technology of the future, which is one of the most important outputs of the fourth industrial revolution, and artificial inte

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Oct 07 2026
Journal Name
Basra Studies Journal
Impact of Digital Sociology on Land Usage in New Cities
...Show More Authors

View Publication
Publication Date
Sun Dec 16 2018
Journal Name
Al-academy
The Aesthetics of the Digital Sound Effects in Television Drama
...Show More Authors

The sound effects in TV dramas achievements have become very important not only in terms of function and implementation, but at a greater and wider level in terms of artistic and aesthetic values, which are produced and employed in the most important world artistic achievements of drama, using the latest and most prominent technologies and equipment and according to the expressive and dramatic values expressed by these modern digital sound effects. Therefore, the researcher chose the aesthetic effect of digital sound effects in television drama to identify the aesthetic aspects provided by digital sound effects by employing them and their accompaniment for the image.

The researcher, therefor, divided this study into the methodolo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 01 2009
Journal Name
Al-khwarizmi Engineering Journal
Multidimensional Systolic Arrays of LMS Algorithm Adaptive (FIR) Digital Filters
...Show More Authors

A multidimensional systolic arrays realization of LMS algorithm by a method of mapping regular algorithm onto processor array, are designed. They are based on appropriately selected 1-D systolic array filter that depends on the inner product sum systolic implementation. Various arrays may be derived that exhibit a regular arrangement of the cells (processors) and local interconnection pattern, which are important for VLSI implementation. It reduces latency time and increases the throughput rate in comparison to classical 1-D systolic arrays. The 3-D multilayered array consists of 2-D layers, which are connected with each other only by edges. Such arrays for LMS-based adaptive (FIR) filter may be opposed the fundamental requirements of fa

... Show More
View Publication Preview PDF
Publication Date
Thu Nov 02 2017
Journal Name
Iraqi Journal Of Laser
Enhancement the Sensitivity of Humidity Sensor Based on an Agarose Coating Transmission-Type Photonic Crystal Fiber Interferometer
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o

... Show More
View Publication Preview PDF