Preferred Language
Articles
/
fhefCpEBVTCNdQwCvZJA
Effective working parameters of laser micro-/nano-machining
...Show More Authors

Modern emerged technologies impose development and fabrication of miniatur-ized parts and devices in the micro- and nano-scale. Producing micro- and nano-featured structures requires nonconventional machining processes where con-ventional machining processes such as grinding, milling and eroding have failed. New emerging processes, such laser machining processes, are still fraught with almost invincible processes. Micro-/nano-machining are the pro-cesses of producing parts, microsystems or features at a scale of a few microm-eters and less than one hundred nanometers, respectively. Precise cutting and clean material removal accompanied with a negligible heat affected zone (HAZ), which are usually the characteristics of laser ablation, have opened a wide door for the evolution of remarkable technologies. This has been demonstrated by applications in different fields such as medicine, biotechnology, materials pro-cessing, microelectromechanical systems, electronics and communications. The continuous development in laser technology in terms of ultra-short pulse width, short wavelength and optics technologies has reduced the drawbacks of diffrac-tion-limited processing accuracies. Laser micro-/nano-machining requires the attainment of high fluence and short interaction time to achieve ablation pro-cesses in nanofabrication and structuring of different materials. To conduct the optimum desired machining process, it is important to integrally consider a number of laser beam and working parameters. Laser wavelength, beam mode, minimum attainable spot size, peak power, pulse duration, pulse repetition rate and scanning speed are some of the important considerations. Manipulating those parameters is crucial for ideal laser ablation represented by yielding the highest resolution of machining with the least lateral dimensions, acceptable depth and minimal or no melt at the edges. The assembly of laser beam delivery and focusing system with an automation system are the essential factors for workpiece positioning and obtaining the desired dimensions. The objective of this chapter is to review the effective parameters associated with laser machin-ing processes that affect the dimensions and quality of laser machining at the micro-/nano-scales in a simple presentation. The review is supported by demonstrating laser processing techniques applied in the field of micro-/nano-machining such as mask, interferometric and scribing techniques.

Crossref
View Publication
Publication Date
Mon Jan 01 2018
Journal Name
Iraqi Journal Of Agricultural Sciences, 2018, 49(2), Pp. 179–187
Estimation of some genetic parameters for grain yield and its components of maize under watered and water stress
...Show More Authors

Scopus (8)
Scopus
Publication Date
Thu Oct 01 2020
Journal Name
Pakistan Journal Of Medical And Health Sciences
Relation of red cell width diameter with some electrophysiological parameters of symptomatic sinus node patients in Iraq(Article)
...Show More Authors

Background: Dysfunction of sinoatrial node is a set of abnormal rhythms which are resulted from the sinoatrial node malfunctionof the sinus node, the chief natural cardiac pacemaker. The common, and occasionally, the single method for treatment of heart arrhythmias wasimplantation of pacemaker, which reduce symptoms exactly occurs after implantation. Aim: To detect the association between red cell width diameter (RDW) and some cardiac electrophysiology parameters in sinus node dysfunction in Iraqi patients such as SNRT and AH. Methods: A cross sectional study, was conducted on 59 patient ranging between 20-50 years old and involving 35 female and 24 male patients, suffering from an unexplained symptoms of sinoatrial node dysfunction (SND).

... Show More
View Publication
Publication Date
Thu Mar 31 2022
Journal Name
Iraqi Geological Journal
Development of New Models to Determine the Rheological Parameters of Water-Based Drilling Fluid using Artificial Neural Networks
...Show More Authors

It is well known that drilling fluid is a key parameter for optimizing drilling operations, cleaning the hole, and managing the rig hydraulics and margins of surge and swab pressures. Although the experimental works represent valid and reliable results, they are expensive and time consuming. In contrast, continuous and regular determination of the rheological fluid properties can perform its essential functions during good construction. The aim of this study is to develop empirical models to estimate the drilling mud rheological properties of water-based fluids with less need for lab measurements. This study provides two predictive techniques, multiple regression analysis and artificial neural networks, to determine the rheological

... Show More
Crossref
Publication Date
Fri Mar 15 2019
Journal Name
Journal Of Baghdad College Of Dentistry
Effects of Oral Supplementation of Pomegranate Peel Extract on Some serum biochemical Parameters Related with Bone in Rabbit
...Show More Authors

Background and aim: Pomegranate is a medicinal herb that can promote healing of periodontal tissue through differentiation of mesenchymal cells both in vivo and in vitro. Therefore, this study is to investigate the effect of oral supplementation of Punicagranatum L. peel extract on bone defect in rabbit. Methods: Forty five male rabbits were divided into 3 groups; group 1; baseline group(5 rabbits) left without bone defect. Group 2; study group (20 rabbits) with bone defect model that received daily 1ml of oral supplementation of pomegranate peel extract (PoPx). Group 3; control group (20 rabbits) with bone defect model that received distilled water. Bone defect was done into facial plate of lower right central incisor. Blood biopsies by

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Effect of Design Parameters and Support Conditions on Natural Frequency of Pipe Excited by a Turbulent Internal Flow
...Show More Authors

In this study, the effect of design parameters such as pipe diameter, pipe wall thickness, pipe material and the effect of fluid velocity on the natural frequency of fluid-structure interaction in straight pipe conveying fully developed turbulent flow were investigate numerically,analytically and experimentally. Also the effect of support conditions, simply-simply and clamped-clamped was investigated. Experimentally, pipe vibrations were characterized by accelerometer mounted on the pipe wall. The natural frequencies of vibration were analyzed by using Fast Fourier Transformer (FFT). Five test sections of two different pipe diameters of 76.2
mm and 50.8 mm with two pipe thicknesses of 3.7 mm and 2.4 mm and two pipe materials,stainles

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jun 02 2011
Journal Name
Ibn Al-haithem Journal For Pure And Applied Sciences
On modified pr-test double stage shrinkage estimators for estimate the parameters of simple linear regression model
...Show More Authors

Publication Date
Sun Sep 01 2019
Journal Name
Baghdad Science Journal
Removing of Hexavalent Chromium from Aqueous Solutions Using Dried Yogurt, and Studying Isotherm, Kinetic and Thermodynamic Parameters
...Show More Authors

     In this study, Yogurt was dried and milled, then shaked with distilled water to remove the soluble materials, then again dried and milled. Batch experiments were carried out to remove hexavalent chromium from aqueous solutions. Different parameters were optimized such as amount of adsorbent, treatment time, pH and concentration of adsorbate. The concentrations of Cr6+ in solutions are determined by UV-Visible spectrophotometer.  Maximum percentage removal of Cr6+ was 82% at pH 2. Two equilibrium adsorption isotherms mechanisms are tested Langmuir and Freundlich, the results showed that the isotherm obeyed to Freundlich isotherm. Kinetic models were applied to the adsorption of Cr6+ ions on the adsorbents, ps

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sun Sep 30 2001
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Determination of Corrosion Parameters for a Cathodic Reaction Complicated by IR Drop Effect in a Flow System
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Feb 22 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Correlation between Streptococci Mutans and salivary IgA in relation to some oral parameters in saliva of children
...Show More Authors

Background: Saliva plays an important role in oral health. Several salivary proteins are involved in the antimicrobial defence mechanism and are able to eliminate or inhibit bacterial growth in the oral cavity. Secretory IgA (SIgA) is one of the principal antibodies present in saliva, could help oral immunity by preventing microbial adherence, neutralizing enzymes and toxins. The aim of this study was to investigate the relationship between salivary Streptococcus Mutans (SM) count and S IgA in stimulated whole saliva in children with primary dentition compared to those with permanent teeth in relation to some oral hygiene parameters. Material and methods: Stimulated whole saliva was collected from 50 children (25 with primary dentation and

... Show More
View Publication Preview PDF
Publication Date
Tue Sep 04 2018
Journal Name
Al-khwarizmi Engineering Journal
Study the Effect of Cutting Parameters on Temperature Distribution and Tool Life During Turning Stainless Steel 316L
...Show More Authors

This paper is focused on studying the effect of cutting parameters (spindle speed, feed and depth of cut) on the response (temperature and tool life) during turning process. The inserts used in this study are carbide inserts coated with TiAlN (Titanum, Aluminium and Nitride) for machining a shaft of stainless steel 316L. Finite difference method was used to find the temperature distribution. The experimental results were done using infrared camera while the simulation process was performed using Matlab software package. The results showed that the  maximum difference between the experimental and simulation results was equal to 19.3 , so, a good agreement between the experimental and simulation results  was achieved. Tool life w

... Show More
View Publication Preview PDF
Crossref (1)
Crossref