Semi-active suspension systems have emerged as an attractive alternative to fully active suspensions because they offer a superior capacity to improve vehicle ride comfort and handling performance with significantly lower energy consumption. Conventional semi-active control strategies, however, such as skyhook damping, often cannot accommodate the nonlinear and time-varying dynamics of vehicles in operation under impulse or severe road disturbances. In this context, an intelligent smart-damper controller is proposed in this paper by incorporating a Modified Fuzzy Adaptive Fuzzy Logic Control framework in a half-car suspension model. In the developed controller, the effective damping force is adaptively tuned using real-time measurements of body acceleration and velocity to achieve enhanced dynamic robustness. The research contribution is the development of an adaptive, computationally efficient semi-active control law that is capable of achieving superior performance over conventional skyhook damping in the case of highly transient excitations. For this purpose, a comprehensive simulation study has been carried out to evaluate the passive, skyhook, and MFAFLC suspensions for identical Gaussian impulse road profiles. The MFAFLC system results in substantial improvements over passive suspension by reducing peak body displacement by 48.6%, pitch angle by 42.1%, and vertical acceleration by 55.7%, while reducing settling times by 35–50%. MFAFLC thus offers a further improvement of 12–25% over skyhook control for most performance indices. These results illustrate that MFAFLC-based smart damping promises to be a more adaptive and effective solution for semi-active vibration control in vehicles subjected to unpredictable road disturbances.
In this paper, the error distribution function is estimated for the single index model by the empirical distribution function and the kernel distribution function. Refined minimum average variance estimation (RMAVE) method is used for estimating single index model. We use simulation experiments to compare the two estimation methods for error distribution function with different sample sizes, the results show that the kernel distribution function is better than the empirical distribution function.
A modification to cascaded single-stage distributed amplifier (CSSDA) design by using active inductor is proposed. This modification is shown to render the amplifier suitable for high gain operation in small on-chip area. Microwave office program simulation of the Novel design approach shows that it has performance compatible with the conventional distributed amplifiers but with smaller area. The CSSDA is suitable for optical and satellite communication systems.
This paper describes DC motor speed control based on optimal Linear Quadratic Regulator (LQR) technique. Controller's objective is to maintain the speed of rotation of the motor shaft with a particular step response.The controller is modeled in MATLAB environment, the simulation results show that the proposed controller gives better performance and less settling time when compared with the traditional PID controller.
Over the years, the prediction of penetration rate (ROP) has played a key rule for drilling engineers due it is effect on the optimization of various parameters that related to substantial cost saving. Many researchers have continually worked to optimize penetration rate. A major issue with most published studies is that there is no simple model currently available to guarantee the ROP prediction.
The main objective of this study is to further improve ROP prediction using two predictive methods, multiple regression analysis (MRA) and artificial neural networks (ANNs). A field case in SE Iraq was conducted to predict the ROP from a large number of parame
The Khor Mor gas-condensate processing plant in Iraq is currently facing operational challenges due to foaming issues in the sweetening tower caused by high-soluble hydrocarbon liquids entering the tower. The root cause of the problem could be liquid carry-over as the separation vessels within the plant fail to remove liquid droplets from the gas phase. This study employs Aspen HYSYS v.11 software to investigate the performance of the industrial three-phase horizontal separator, Bravo #2, located upstream of the Khor Mor sweetening tower, under both current and future operational conditions. The simulation results, regarding the size distribution of liquid droplets in the gas product and the efficiency gas/liquid separation, r
... Show MoreThe Feedback Concept has been spread as an organized trend for scientific research since it has a significant importance for human behavior and how it has been directed and controlled by the individual, feedback has numerous definitions but the simplest definition is; feedback is the information received by the individual from the output of his behavior, In addition to the mutual relationship between the individual and the stimulation that provide him with the basic information by the biological control of his behavior, Since feedback cannot be accomplished without receiving information from the inner and outer environment, the biological and physiological information become the ma
... Show MoreThis paper discusses using H2 and H∞ robust control approaches for designing control systems. These approaches are applied to elementary control system designs, and their respective implementation and pros and cons are introduced. The H∞ control synthesis mainly enforces closed-loop stability, covering some physical constraints and limitations. While noise rejection and disturbance attenuation are more naturally expressed in performance optimization, which can represent the H2 control synthesis problem. The paper also applies these two methodologies to multi-plant systems to study the stability and performance of the designed controllers. Simulation results show that the H2 controller tracks a desirable cl
... Show More