Background :The cotton factories have difference steps, spinning and weaving are van important parts of the factories. Cotton industry workers are exposed to various hazards in the different departments of textile factories. The major health problems associated with cotton dust are respiratory problems. Cotton workers display an excess of lung function abnormalities when compared to a community control population.
Aim of Study: This study assessed the effect of exposure to cotton dust in spinning and weaving workers on the lung function in Iraq, by measuring Forced Vital Capacity (FVC),Forced Expiratory Volume in the first second(FEV1), FEV1 ∕ FVC Ratio, and Forced Expiratory Flow 50%(FEF50%),with varying degree of reduction in lung
A cross-sectional study was conducted on 80 type 2 diabetic patients aged 20-60 years in Baghdad and 20 non diabetic persons as controls. Laboratory assessment of glucose related parameters; Fasting blood sugar (FBS), Glycated hemoglobin (HbA1c), Insulin and Insulin resistance (IR), renal function test; Blood urea, serum creatinine, Calcium (Ca) and Phosphorus (P), Calcium regulating hormones; Parathyroid hormone (PTH), calcitonin and vitamin D, cytokines, Adiponectin and Tumor necrosis factor (TNF-α) and comparison these parameters between patients and controls. The results: a high significant (p˂0.01) increase in FBG level in the patients (211.34 ± 11.20 mg/dl) as compared with control (85.89 ± 3.07 mg/dl). A high significant (p˂0.01
... Show MoreThe calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test sect
... Show MoreEvaluation of Dot. ELISA test for Diagnosis Visceral Leishmaniasis in Infected Children
The calibration of a low-speed wind tunnel (LSWT) test section had been made in the present work. The tunnel was designed and constructed at the Aerodynamics Lab. in the Mechanical Engineering Department/University of Baghdad. The test section design speed is 70 m/s. Frictional loses and uniformity of the flow inside the test section had been tested and calibrated based on the British standards for flow inside ducts and conduits. Pitot-static tube, boundary layer Pitot tube were the main instruments which were used in the present work to measure the flow characteristics with emphasize on the velocity uniformity and boundary layer growth along the walls of the test section. It is found that the maximum calibrated velocity for empty test s
... Show MoreBackground: Ultrasound provides a powerful tool for assessing early pregnancy and detecting pregnancy failure at first trimester and promoting rapid effective management. Several criteria have been established to predict the pregnancy outcome particularly in symptomatic women .
Aim: To evaluate asymptomatic women at the first trimester of pregnancy , to assess the efficacy of certain ratios as mid sac diameter (MSD) / yolk sac ratio & crown rump length (CRL)/mid sac diameter (as indicator of early first trimester oligohydramnios) in predicting poor 1st trimester outcome
Type of the study: A cross-s
... Show More