This numerical study explores dynamic melting as an enhancement strategy to improve heat transfer in thermal energy storage (TES) systems utilizing phase change materials (PCM) with openings. Optimizing such systems is crucial for advancing renewable energy storage and integration. A 3D model simulates RT35 PCM flowing through a shell-and-tube heat exchanger annulus. The effects of varying PCM inlet slot diameter (2.5–7.5 mm), inlet pressure (1–40 Pa), and inlet/outlet port positioning on melting fraction and temperature distributions are computationally evaluated. Results show that increasing slot diameter from 2.5 mm to 7.5 mm reduces melting time by 13.6 % (from 550 to 475 min). Raising inlet pressure from 10 Pa to 40 Pa cuts melting time by 43.8 % (from 400 to 225 min). However, varying inlet/outlet port positioning has negligible impact. Larger slot diameters and higher pressures produce more homogeneous melting across the radial width. A neural network approach revealed that port diameters around 5.5 mm maximized melting volume fraction at early stages, while increasing port size accelerated melting in later stages. This study provides quantitative data demonstrating that optimizing dynamic melting parameters through the annulus can substantially enhance heat transfer in open PCM-based TES systems. The novelty lies in systematically evaluating the effects of these design parameters on melting behavior and employing artificial intelligence to further analyze parameter interactions
Doxorubicin (DOX) is a chemotherapeutic agent; it is widely used in human malignancies. Its long-term use can cause neurobiological side-effects. Vitamin E and Coenzyme Q10may possess neuroprotective effects. This work was designed to investigate the effect of vitamin E and the coenzyme Q10(CoQ10) supplementation on neurotoxicity induced by doxorubicin(DOX) in rats. Forty nine adult rats of both sexes were used in this study; the animals were randomly enrolled into seven groups of 7 rats each. Group I: negative control (rats administered corn oil); Group II: Vitamin E at a dose of 100mg/kg/d for 3 weeks ; Group III: CoQ10 at a dose of 50 mg/kg/d for 3 weeks; Group IV: positive control (Doxorubicin 2
... Show MorePrevious reports demonstrated the effectiveness of silibinin hemisuccinate as a potential intraocular pressure-lowering agent. The exact mechanism by which silibinin exerted this effect has not yet been documented, but might suggested to interfere with aqueous humor formation. The present study was designed to evaluate the comparative efficacy of silibinin as IOP lowering agent to that of betaxolol in normotensive rabbits, and the interaction of silibinin with betaxolol as a way for investigating the possible mechanism of action of silibinin in this respect. The effects of instillation of 0.75% silibinin solution and 0.5% betaxolol eye drops in the eyes of normotensive rabbits were evaluated using indentation tonometry. The results showe
... Show MoreOver the last few years, the interior designer has been given the ability to access many innovative tools for new forms of unprecedented diversity and efficiency. Some design experts have described the new parametric procedures they are introducing to create new interior projects as a radical transformation that carries all the elements of a qualitative shift in interior design. The best of these parametric procedures is the technical capabilities offered by us to create new forms that are different from what has been discussed in everything that has been produced by designers and architects since modernity and even before it to the present time, which returns our design products through a series of computer programs that perform the pro
... Show MoreThis paper presents an investigation to the effect of the forming speed on healing voids that inhabit at various size in an ingot. The study was performed by using finite element method with bilinear isotropic material option, circular type voids were considered. The closure index was able to predict the minimum press force necessary to consolidate voids and the reduction. The simulation was carried out, on circular cross-section lead specials containing a central void of different size. At a time with a flat die, different ratio of inside to outside radius was taken with different speed to find the best result of void closure.
This work suggests a system of ordinary differential equations (ODEs) containing a three-species food chain model incorporating wind and fear effects. The properties of the solution, like positivity and bound-ness, were investigated. All equilibrium points (biologically feasible) have been obtained, and the local stability of these equilibriums has been carried out. The global stability outcomes on the equilibrium points under specific restrictions have been established. Also, the persistence restrictions have been investigated. By utilizing Sotomayor’s theorem, the local bifurcation of the suggested model has been inspected. Furthermore, numerical analysis was carried out to ensure the theoretical results obtained by utilizing MA
... Show MoreAnalyzing plantar pressure trajectories is crucial for assessing foot behavior in dynamic gait stability. We propose the identification of foot symmetry and the detection of deformities by analyzing the trajectories of the center of pressure (CoP) and peak pressure (PP). First, using a foot pressure mapping system, plantar pressure data are acquired during a normal gait cycle. After the data have been acquired, post processing extracts both the CoP and PP trajectories over the spatiotemporal domain of foot motion for each foot independently. For this purpose, we used the optical flow technique which accurately estimates the direction of foot motion. The extracted trajectories of each foot are then segmented into, the medial and lateral regi
... Show MoreIn this research, a modified artificial hand with direct control has been designed using electrical artificial muscle wires that receive direct sensory impulses through human hand instead of using the mechanical action to open and close this artificial hand. Each finger is designed as a chain and its movements achieved through the conventional arrangement control of the electrical muscles wires. The results indicate that it is possible to design an artificial hand using electrical muscle wire for control it with high accuracy.
