Preferred Language
Articles
/
ehaWOogBVTCNdQwCm3Xz
Corrosion protection of pure titanium implant by electrochemical deposition of hydroxyapatite post-anodizing
...Show More Authors

In this study, a Hydroxyapatite (HA) coating was prepared on a titanium implant by an electrochemical deposition process. The titanium pre-treatment by anodizing in 1.65 mol/L sulfuric acid with (10V) at room temperature. The deposition was all conducted at a constant voltage of 6.0 V, for 1 h at room temperature. The coatings thus prepared were characterized with Fourier transform infrared spectroscopy (FTIR) and thickness of the coated layer.The electrochemical deposition of HA occurred on the titanium as a cathode. Coated titanium by HA after anodizing revealed a good corrosion protection efficiency even at a temperature ranged (293-323) K in artificial saliva. Activation energy and pre-exponential factor (kinetic parameters) were calculated and discussed. Also, thermodynamic values ΔG and ΔH were calculated and it shows that corrosion reaction was non-spontaneous and exothermic in nature before treatment but after anodizing the corrosion reaction become endothermic.

Scopus
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sat Mar 03 2018
Journal Name
International Journal Of Science And Research
In Vivo Mechanical and Histological Evaluation of the Effect of Vacuum Storage and Ultra Violet Light Treatment of Titanium Implants on Osseointegration
...Show More Authors

Background: Titanium implant is widely used in dentistry because of its extraordinary biocompatibility and mechanical properties. To increase bone–implant connection and provide early loading after placement, implant is stored in different storage medium and treated with UV light. Both of them are applicable methods to increase the bioactivity of titanium and overcome the biological aging. This study was designed to assess the effect of vacuum storage method and air storage with and without UV light treated of Cp Ti implant mechanically and histologically. Materials and methods: Titanium screws were acid etched and prepared in four different modes using different storage methods (air or vacuum and, with or without UV treatment. The implan

... Show More
Preview PDF
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Different Fluoride Agents on the Load Deflection Characteristics of Heat Activated Nickel Titanium Arch Wires (An in Vitro Study)
...Show More Authors

ABSTRACT Background:Hydrogen absorption and related degradation in the mechanical properties of Ni-Ti based orthodontic wires has been demonstrated following exposure to fluoride prophylactic agents. This study was designed to investigate the effects of three fluoride containing agents on the load deflection characteristics of heat activated nickel titanium arch wires during unloading phase. Material and method: Eighty specimens of heat activated nickel titanium arch wires were obtained from Ortho Technology Company, half of which had a 0.016 inch round and 0.019x0.025 rectangular. Ten specimens from both wire size were immersed in one of the tested fluoride prophylactic agents (neutral sodium fluoride gel, stannous fluoride gel or phos-flu

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Feb 11 2019
Journal Name
Journal Of Pharmaceutical Sciences And Research
Design of experiments model for optimization of spectrophotometric determination of phenylephrine hydrochloride in pure and pharmaceutical formulations using p-bromanil
...Show More Authors

A simple, fast, inexpensive and sensitive method has been proposed to screen and optimize experimental factors that effecting the determination of phenylephrine hydrochloride (PHE.HCl) in pure and pharmaceutical formulations. The method is based on the development of brown-colored charge transfer (CT) complex with p-Bromanil (p-Br) in an alkaline medium (pH=9) with 1.07 min after heating at 80 °C. ‘Design of Experiments’ (DOE) employing ‘Central Composite Face Centered Design’ (CCF) and ‘Response Surface Methodology’ (RSM) were applied as an improvement to traditional ‘One Variable at Time’ (OVAT) approach to evaluate the effects of variations in selected factors (volume of 5×10-3 M p-Br, heating time, and temperature) on

... Show More
View Publication
Scopus
Publication Date
Thu Dec 15 2022
Journal Name
Romanian Neurosurgery
Mobilization of the temporal pole as integrated step in microsurgical clipping of pure posteriorly directed posterior communicating artery aneurysm
...Show More Authors

A pure posteriorly posterior communicating artery (PCoA) aneurysm represents a surgical challenge. This is mainly when there is a need for good exposure of the aneurysmal neck, sac, PCoA, and anterior choroidal arteries. Ruptured pure posteriorly directed PCoA aneurysm imposes significantly extra challenge as the surgeon undergoes dissection through a tight brain. Even with measures commonly used to attain brain relaxation like the lumbar drain and cisternal fenestration. Here, we describe a technique for posterior temporal pole mobilization (TPM) as an integrated part of microsurgical clipping of ruptured pure posteriorly directed PCoA aneurysms. This technique is implicated in twenty-three successive cases of ruptured PCoA aneurys

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Sep 15 2022
Journal Name
Romanian Neurosurgery
Impact of dome projection on operative steps during clipping of a ruptured pure posteriorly directed posterior communicating artery aneurysms
...Show More Authors

Background: Ruptured posterior communicating artery (PCoA) aneurysms are common; they usually present with subarachnoid haemorrhage (SAH) and oculomotor nerve palsy. The aneurysmal dome projection may influence the safety access and aneurysmal neck clipping. Here, we discuss additional intraoperative steps that may be required to widen the surgical field to ensure safe surgical clipping of a rupture pure posteriorly directed PCoA aneurysm. Case description: A previously healthy 38-year-old male reported sudden severe headache and disturbed level of consciousness with a Glasgow coma scale (GCS) of 13. His initial computed tomography (CT) scan of the head showed SAH in the basal cistern. 3D-constructed CT angiography (CTA) revealed a

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Sep 20 2024
Journal Name
Linguistic And Philosophical Investigations
Mental Alertness among Students of the Chemistry Department at the College of Education for Pure Sciences - Ibn Al-Haytham
...Show More Authors

The current research aims to identify the level of mental alertness among students of the Department of Chemistry in the Faculty of Education for Pure Sciences – Ibn Al-Haytham during the academic year (2022-2023). To achieve this goal, a descriptive approach was followed. The research community was identified as all chemistry students across the four grades (first, second, third, and fourth). A sample from each grade was selected for the current research. A tool was prepared to measure mental alertness within the research sample. The researcher adopted the scale by Baer, Smith, Kristemoyer, & Tany (2006), which was developed by Al-Buhairi et al. (2014), ensuring its validity, reliability, and psychometric characteristics, making i

... Show More
Preview PDF
Publication Date
Mon May 01 2017
Journal Name
Journal Of Arab Studies In Education & Psychology (asep)
Procedural Knowledge for the, Mathematics Departments Students, College of Education for Pure Sciences / Ibn al-Haytham, University of Baghdad
...Show More Authors

Publication Date
Mon Jan 01 2018
Journal Name
Al–bahith Al–a'alami
News website Analytical: study of news sites (Iraqi Media network, The Seventh Day,Huffington Post Arabic
...Show More Authors

This research focuses on the services provided by news websites (IMN, Youm7, Huffington Post Arabic) to its audience of Internet users, as well as materials posted through its pages, trying to monitor and explain them to identify their types & features, and it›s functions, whether informational or non-informational, to know the technical potential of each of the news sites, with the entry of the latest technology information. The research used the analysis method to achieve the research objectives within the period from 1/1 to 31/1/2017. The researchers used the content analysis tool as a research tool to analyze the news sites and to know the services they provide through their pages. The research was divided into three parts, the

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Jun 25 2020
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Comparing the Efficacy of Paracetamol, Diclofenac, and Ketorolac on Post-Appendectomy Outcomes in Children and Adolescents
...Show More Authors

Abstract

urgent surgical intervention and appendectomy until now represent standard treatment for uncomplicated cases of appendicitis. Nausea, vomiting and pain after surgery are the most frequent issues facing patients and affecting patient quality of life and responsible for many cases of readmission after surgery. Ketorolac and diclofenac represent the most commonly prescribed non-steroidal anti-inflammatory used in postoperative setting and they cause many side effects as gastrointestinal, kidney and cardiac adverse effect in addition to increased risk of bleeding. Paracetamol is currently among the most frequently prescribed medication worldwide and it can be used safely for all age groups. This study aimed

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Wed Oct 22 2025
Journal Name
Journal Of Composites And Biodegradable Polymers
Experimental Behavior of One-Way RC Ultra-Thin Slabs Retrofitted with Post-Installed NSM CFRP Rods
...Show More Authors

This study evaluates the flexural behavior of ultra-thin (50 mm) one‑way reinforced‑concrete (RC) slabs retrofitted with near‑surface mounted (NSM) carbon‑fiber‑reinforced polymer (CFRP) rods under quasi‑static loading. T300‑grade CFRP rods (≈4 mm diameter) were bonded in pre‑cut 7 mm × 7 mm grooves using a two‑part epoxy. As a proof-of-concept experimental baseline, three simply‑supported specimens (1000 mm × 500 mm × 50 mm) were tested in a six‑point bending configuration (four applied loads + two reactions): two conventional controls and one strengthened slab. A load‑control rate of ~15 kN/min was applied; the controls were cycled twice and the strengthened slab four times. Relative to the average of

... Show More
View Publication Preview PDF
Scopus Crossref