Preferred Language
Articles
/
eBbqXIcBVTCNdQwCIUfp
Experimental polyethylene-hydroxyapatite carrier-based endodontic system: an in vitro study on dynamic thermomechanical properties, sealing ability, and measurements of micro-computed tomography voids
...Show More Authors

The dynamic thermomechanical properties, sealing ability, and voids formation of an experimental obturation hydroxyapatite-reinforced polyethylene (HA/PE) composite/carrier system were investigated and compared with those of a commercial system [GuttaCore (GC)]. The HA/PE system was specifically designed using a melt-extrusion process. The viscoelastic properties of HA/PE were determined using a dynamic thermomechanical analyser. Human single-rooted teeth were endodontically instrumented and obturated using HA/PE or GC systems, and then sealing ability was assessed using a fluid filtration system. In addition, micro-computed tomography (μCT) was used to quantify apparent voids within the root-canal space. The data were statistically analysed using one-way anova and post hoc tests. The HA/PE composite exhibited important modulus and damping changes with an increase of temperature. The HA/PE system was more flexible than GC as the modulus of GC appeared to be significantly higher than that of HA/PE as a result of the high positive glass transition temperature (Tg). However, HA/PE and GC presented similar sealing abilities. In conclusion, because sealing ability and voids formation were comparable between the tested materials, the experimental HA/PE system may be considered a suitable alternative material for root-canal obturation. Moreover, HA/PE possesses specific viscoelastic behaviour and lower melting points, which may facilitate root-canal retreatments.

Clarivate Crossref
View Publication
Publication Date
Sat Jul 01 2023
Journal Name
Heliyon
Effect of plasma surface treatment of three different CAD/CAM materials on the micro shear bond strength with resin cement (A comparative in vitro study)
...Show More Authors

Objectives: This study aimed to evaluate and compare the effect of plasma treatment versus conventional treatment on the micro shear bond strength (μSBS), surface roughness, and wettability of three different CAD/CAM materials. Materials and methods: Sixty cylindrical specimens (5 mm diameter ×3 mm height) were prepared from three different CAD/CAM materials: Group A: Zirconia, Group B: Lithium disilicate, and Group C: Resin nano-ceramic. Each group was subdivided into two subgroups according to surface treatment used: Subgroup I: Conventional treatment, zirconia was sandblasted with Al2O3, while lithium disilicate and resin nano-ceramic were etched with hydrofluoric acid. Subgroup II: Plasma treatment, the surface of each material was tr

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (15)
Scopus Clarivate Crossref
Publication Date
Mon Jan 01 2018
Journal Name
African Journal Of Hospitality, Tourism And Leisure
An analytical study of the strategic flexibility variation as a function of the dynamic capabilities based on supply chain management (Case study: The General Petroleum Products Distribution Company in Baghdad)
...Show More Authors

Scopus (10)
Scopus
Publication Date
Thu May 01 2025
Journal Name
International Journal Of Engineering
Impact of Using Polyethylene Polymer on Properties of Hot Asphalt Mixture by Conducting Semi-Wet and Dry Mixing Process
...Show More Authors

In recent years, various methods have been developed to enhance the characteristics of asphalt pavement in order to face the continuous challenges of increasing traffic loads and changing climate conditions. One of the most popular and successful methods is modifying the asphalt mixtures or asphalt binder with the addition of polymers. Therefore, two types of Polyethylene (PE) polymer, High-Density PE (HDPE) and Low-Density PE (LDPE), are used in this research. Two methods were applied to prepare PE-modified asphalt mixtures: Semi-Wet Method (S-WM) and Dry Method (DM). The findings of the investigation indicated that the addition of PE polymer can reduce the wear loss of aggregate. In general, the experimental results revealed that asphalt

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Tue Jun 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Color Stability of Different Aesthetic Archwires (An In vitro study)
...Show More Authors

Background: Coated aesthetic archwires are currently the existing solutions for the esthetic problem, but the color of these archwires tends to change overtime. This study was aimed to evaluate the color stability of different types of esthetic archwires from four different companies at different time periods after immersion of two different staining drinks which are tea and Pepsi cola. Materials and methods: 48 specimens were prepared, each specimen contains 10 aesthetic archwires; and were divided according to type of solution into two groups: A (tea) &B (Pepsi cola); each group contained 24 specimens (12 specimens were immersed in the staining solution as 4 specimens for each time intervals and 12 specimens were immersed in distilled wa

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Jun 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Radiopacity of modified microhybrid composite resin:(An in vitro study)
...Show More Authors

Background: The aim of this study was to measure the radiopacity (RO) of modified microhybrid composite resins by adding 2 types of nanofillers (Zinc Oxide and Calcium Carbonate) in two concentrations 3% and 5% and comparing them to unmodified microhybrid composite resins and to nanofilled composite resin. Materials and Methods: Two types of composite resin were used (Microhybrid composite MH Quadrent anterior shine and Nanofilled composite resin Filtek Z350 XT), for each tested group five disk-shaped specimens (1-mm-thick and 15 mm diameter) were fabricated. The material samples were radiographed together with the aluminum step wedge. The density of the specimens was determined with a transmission densitometer and was expressed in term of

... Show More
View Publication Preview PDF
Publication Date
Sat Dec 01 2018
Journal Name
2018 Third Scientific Conference Of Electrical Engineering (scee)
An Intelligent Cognitive System Design for Mobile Robot based on Optimization Algorithm
...Show More Authors

View Publication
Scopus (8)
Scopus Crossref
Publication Date
Wed Sep 07 2022
Journal Name
2022 Iraqi International Conference On Communication And Information Technologies (iiccit)
Construct an Efficient DDoS Attack Detection System Based on RF-C4.5-GridSearchCV
...Show More Authors

View Publication
Scopus (5)
Crossref (3)
Scopus Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
Testing Different Properties of A Light-Cured Denture Base Material After Addition of Silicon Oxide Nanofiller (An in Vitro Study)
...Show More Authors

ABSTRACT Background: Improving the properties of heat- cured and self-cured acrylic resin have been studied by many researchers. However, little studies concerned with visible light cured resin (VLCR) improved through addition of nanofiller are available. The purpose of this study was to evaluate some properties of (VLCR) after addition of SiO2 nanofiller. Materials and Methods: SiO2 nanofiller were added to (VLCR) tray material after being dissolved in tetrahydrofuran (THF) solvent. According to the pilot study 2% SiO2 nanofiller addition exhibited better properties than the other percentages (1%, 3%). The main study conducted involved (100) specimens divided into 5 groups according to the test included. (20) Specimens were selecte

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sun Jan 01 2012
Journal Name
Tikrit Journal For Dental Sciences
Microleakage Evaluation of a Silorane-Based and Methacrylate-Based Packable and Nanofill Posterior Composites (in vitro comparative study)
...Show More Authors

This study compared in vitro the microleakage of a new low shrink silorane-based posterior composite (Filtek™ P90) and two methacrylate-based composites: a packable posterior composite (Filtek™ P60) and a nanofill composite (Filtek™ Supreme XT) through dye penetration test. Thirty sound human upper premolars were used in this study. Standardized class V cavities were prepared at the buccal surface of each tooth. The teeth were then divided into three groups of ten teeth each: (Group 1: restored with Filtek™ P90, Group 2: restored with Filtek™ P60, and Group 3: restored with Filtek™ Supreme XT). Each composite system was used according to the manufacturer's instructions with their corresponding adhesive systems. The teeth were th

... Show More
Preview PDF
Publication Date
Tue Jun 30 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Thickness of Buccal Bone at Various Sites of the Mandible and Its Clinical Significance in MonocorticalScrews Placement Using Multi-Slice Computed Tomography
...Show More Authors

Background:Open reduction and internal fixation (ORIF) of using miniplates and screws is the treatment of choice of mandibular fractures. It is important to know both: the region where the bone providesafirm anchorage, andthe topography of the dental apices and inferior alveolar nerve to avoiddamaging them when inserting the screw. The aim of this study is to determine the thickness of buccal cortical plate and that of buccal bone at the parasymphysis and mandibular body, thereby determining the area that provide afirm anchorage and the maximum length of mono-cortical screws that can be safely placed in these regions without injuring the tooth roots or mandibular nerve. Materials and Methods:The sample of the present study was 110 Iraqi sub

... Show More
View Publication Preview PDF