All major organs may be impacted by the connective disease systemic lupus erythematosus, a separate risk factor for coronary artery disease (CAD). Adhesion molecules like intercellular adhesion molecules (ICAM) and vascular cell adhesion molecules (VCAM) can detect endothelial damage and dysfunction, which appear to play a crucial role. This study investigated whether people with SLE had elevated subclinical and clinical atherosclerosis risk factors. Traditional CAD risk factors such as smoking, hypertension, and hyperlipidemia cannot entirely explain this elevation. It is thought that immunological dysfunction also increases CAD risk in SLE patients. The study aimed to assess early endothelial changes in SLE Iraqi female patients without previous coronary artery lesions by exploring a potential relationship between circulating VCAM-1 and ICAM-1 as risk factors for atherosclerosis and the relationship of CAD with SLE disease and its severity; further, the study explained the effect of the hydroxychloroquine (HCQ) on the lipid profile levels of the patients. 92 female SLE patients were divided into mild, moderate, and severe, according to the SLE disease activity index 2000 (SLEDAI-2k), compared with 30 apparently healthy control individuals. All of them need a history of CAD. Serum VCAM-1, ICAM-1 level, VCAM-1/ICAM1 ratio, TC, HDL, LDL levels TC/HDL and LDL/HDL ratios were measured. sVCAM-1, sICAM-1 levels and VCAM-1/ICAM-1 ratio were significantly and gradually increased in patient groups compared with control. Serum TC, HDL and LDL levels were significantly reduced in the SLE patients compared to the control. At the same time, the TC/HDL and LDL/HDL ratios were significantly elevated with the severity of the SLE disease. sVCAM-1, sICAM-1 level and VCAM1/ICAM-1 ratio together with serum TC/HDL and LDL/HDL may improve coronary artery disease risk categorization in SLE patients without acute coronary syndromes. Furthermore, they were more sensitive in severe SLE instances than in moderate and mild ones, suggesting that they may be related to the extent of coronary lesions in SLE patients. VCAM-1 had a higher sensitivity than ICAM-1 in detecting and severity screening for CAD in SLE patients. Keywords: VCAM-1, ICAM-1, SLE, Atherosclerosis
Double-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w
... Show MoreImproving" Jackknife Instrumental Variable Estimation method" using A class of immun algorithm with practical application
According to the theory of regular geometric functions, the relevance of geometry to analysis is a critical feature. One of the significant tools to study operators is to utilize the convolution product. The dynamic techniques of convolution have attracted numerous complex analyses in current research. In this effort, an attempt is made by utilizing the said techniques to study a new linear complex operator connecting an incomplete beta function and a Hurwitz–Lerch zeta function of certain meromorphic functions. Furthermore, we employ a method based on the first-order differential subordination to derive new and better differential complex inequalities, namely differential subordinations.
In this paper, chip and powder copper are used as reinforcing phase in polyester matrix to form composites. Mechanical properties such as flexural strength and impact test of polymer reinforcement copper (powder and chip) were done, the maximum flexural strength for the polymer reinforcement with copper (powder and chip) are (85.13 Mpa) and (50.08 Mpa) respectively was obtained, while the maximum observation energy of the impact test for the polymer reinforcement with copper (powder and chip) are (0.85 J) and (0.4 J) respectively
A series of laboratory model tests has been carried out to investigate the using of pomegranate sticks mat as reinforcement to increase the bearing capacity of footing on loose sand. The influence of depth and length of pomegranate sticks layer was examined. In the present research single layer of pomegranate sticks reinforcement was used to strengthen the loose sand stratum beneath the strip footing. The dimensions of the used foundation were 4*20 cm. The reinforcement layer has been embedded at depth 2, 4 and 8 cm under surcharge stresses . Reinforcing layer with length of 8 and 16 cm were used. The final model test results indicated that the inclusion of pomegranate sticks reinforcement is very effective in improvement the loading cap
... Show Morecharacteristic tissues and cells, exerting their pharmacological aspects and alleviating a lot of diseased processes. Accordingly, this research is about introducing some isatins to be nucleophilically attacked at C3 forming products of azomethine ylide functionality. These iminium compounds were made by allowing certain isatins to be reacted with the secondary amino acid, proline, at acetic acid and methanol medium and then collected after purification to be identified with total Leukocyte count (TLC) and melting point. The structural characterization was performed by fourier-transform infrared spectroscopy (FTIR), proton nuclear magnetic resonance (1H-NMR), and community health nursing (CHN) analysis. The microbiological evaluatio
... Show More