Preferred Language
Articles
/
dhewrpIBVTCNdQwC9r3a
COWPEA NODULATION AND NITROGEN FIXATION UNDER POTYVIRUS AND RHIZOBIUM COINCIDENCE
...Show More Authors

The present study aimed to assess the impact of seed Rhizobia treatment and potyvirus inoculation on bacterial nodulation and nitrogen fixation in cowpeas. The plants were infected with the virus two weeks post-germination. Nodules were present on the roots of plants treated with Rhizobia; however, almost no nodules were detected on untreated plants. The average number of nodules per plant on virus-inoculated plants was significantly lower than the average number per noninoculated plant. The virus caused a substantial decrease in the weight of nodules also. The study revealed that the presence of Rhizobia resulted in a significant rise in nitrogen content in the foliage. Specifically, the nitrogen percentage increased from 1.29% in plants not treated with Rhizobia and not inoculated by the virus to 2.502% in Rhizobia-treated plants that were inoculated by the virus and to 2.550% in Rhizobia-treated plants that were not inoculated by the virus. This difference was statistically significant at a p-value less than 0.05. The virus resulted in a rise in nitrogen content in plants that were not inoculated with Rhizobia. The Rhizobia resulted in a significant augmentation in the number of pods per plant, seed count per plant, and seed dry weight per plant compared to plants that were not treated with Rhizobia. The application of Rhizobia to virus-inoculated plants resulted in a notable enhancement of these parameters, except for the nitrogen content in seeds

Scopus
Publication Date
Thu Oct 15 2015
Journal Name
International Journal Of Computer Applications
Experimental Investigation for Small Horizontal Portable Wind Turbine of Different Blades Profiles under Laboratory Conditions
...Show More Authors

Experimental investigation for small horizontal portable wind turbine (SHPWT) of NACA-44, BP-44, and NACA-63, BP-63 profiles under laboratory conditions at different wind velocity range of (3.7-5.8 m/s) achieved in present work. Experimental data tabulated for 2, 3, 4, and 6- bladed rotor of both profiles within range of blade pitch angles . A mathematical model formulated and computer Code for MATLAB software developed. The least-squares regression is used to fit experimental data. As the majority of previous works have been presented for large scale wind turbines, the aims were to present the performance of (SHPWT) and also to make a comparisons between both profiles to conclude which is the best performance. The overall efficiency and el

... Show More
View Publication
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Ieee Transactions On Power Delivery
Optimal Dielectric Design of Medium Voltage Toroidal Transformer with Electrostatic Shield under Fast Front Excitation
...Show More Authors

Accurate calculation of transient overvoltages and dielectric stresses from fast-front excitations is required to obtain an optimal dielectric design of power components subjected to these conditions, which are commonly due to switching and lightning, as well as utilization of power-electronic devices. Toroidal transformers are generally used at the low voltage level. However, recent investigations and developments have explored their use at the medium voltage level. This paper analyzes the model-based improvement of the insulation design of medium voltage toroidal transformers. Lumped and distributed parameter models are used and compared to predict the transient response and dielectric stress along the transformer winding. The parameters

... Show More
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Tue Dec 31 2024
Journal Name
International Review On Modelling And Simulations (iremos)
Vibration Analysis of Laminated Shallow Shells Under Thermal Loading Using Higher Order Shear Deformation Theory
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Engineering
The Optimum Reinforcement Layer Number for Soil under the Ring Footing Subjected to Inclined Load
...Show More Authors

The primary components of successful engineering projects are time, cost, and quality. The use of the ring footing ensures the presence of these elements. This investigation aims to find the optimum number of geogrid reinforcement layers under ring footing subjected to inclined loading. For this purpose, experimental models were used. The parameters were studied to find the optimum geogrid layers number, including the optimum geogrid layers spacing and the optimum geogrid layers number. The optimum geogrid layers spacing value is 0.5B. And as the load inclination angle increased, the tilting and the tilting improvement percent for the load inclination angles (5°,10°,15°) are (40%,28%, and 5%) respectively. The reduction percent o

... Show More
View Publication
Crossref (5)
Crossref
Publication Date
Wed Dec 25 2019
Journal Name
Journal Of Engineering
Corrosion Rate Optimization of Mild-Steel under Different Cooling Tower Working Parameters Using Taguchi Design
...Show More Authors

This study investigates the implementation of Taguchi design in the estimation of minimum corrosion rate of mild-steel in cooling tower that uses saline solution of different concentration. The experiments were set on the basis of Taguchi’s L16 orthogonal array. The runs were carried out under different condition such as inlet concentration of saline solution, temperature, and flowrate. The Signal-to- Noise ratio and ANOVA analysis were used to define the impact of cooling tower working conditions on the corrosion rate. A regression had been modelled and optimized to identify the optimum level for the working parameters that had been founded to be 13%NaCl, 35ᴼC, and 1 l/min. Also a confirmation run to establish the p

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Response of composite steel-concrete cellular beams of different concrete deck types under harmonic loads
...Show More Authors
Abstract<p>This study aims to investigate the adequacy of composite cellular beams with lightweight reinforced concrete deck slab as a structural unit for harmonic loaded buildings. The experimental program involved three fixed-ends supported beams throughout 2140 mm. Three concrete types were included: Normal Weight Concrete (NWC), Lightweight Aggregate Concrete (LWAC), and Lightweight Fiber Reinforced Aggregate Concrete (LWACF). The considered frequencies were (5, 10, 15, 20, 25, and 30) Hz. It was indicated that the harmonic load caused a significant influence on LWAC response (64% greater than NWC) and lattice cracks were observed, especially at 30 Hz. As for LWACF slab, no cracks appeared, </p> ... Show More
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Engineering
The Optimum Reinforcement Layer Number for Soil under the Ring Footing Subjected to Inclined Load
...Show More Authors

The primary components of successful engineering projects are time, cost, and quality. The use of the ring footing ensures the presence of these elements. This investigation aims to find the optimum number of geogrid reinforcement layers under ring footing subjected to inclined loading. For this purpose, experimental models were used. The parameters were studied to find the optimum geogrid layers number, including the optimum geogrid layers spacing and the optimum geogrid layers number. The optimum geogrid layers spacing value is 0.5B. And as the load inclination angle increased, the tilting and the tilting improvement percent for the load inclination angles (5°,10°,15°) are (40%,28%, and 5%) respectively. The reduction percent of the

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Wed Apr 05 2017
Journal Name
Journal Of Agriculture And Veterinary Science
Tillage Appearance Device Test When Used Mold Board Plow Under Difference of a Variables Condition
...Show More Authors

Tillage appearance device is mechanical, electric-electronic design, getting Patent from the Central Organization for Standardization and Quality Control – Industrial Property Department - Ministry of Planning – The Republic of IRAQ under number Patent 3876 in 20 / 4 / 2014, calculates the number of clods per area by Tillage appearance device, This is done through the generation electrical impulses are sent to the controlled accurate calculates number clods required space and shows the result on the screen in order to see the tillage view per area. Three factor used in these experiment, first factor represents forward speed of tractor three levels (3.5, 4.5, and 5.5 km/h), second factor represent soil moisture content at two levels (14

... Show More
Publication Date
Sun Mar 08 2026
Journal Name
University Of Anbar Sport And Physical Education Sciences
The effect of using aids in spatial sense perception Throwing weights under 18 years old
...Show More Authors

View Publication
Publication Date
Sat Sep 30 2023
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
A proposed program to audit the performance of the hotel sector under crises (Applied Research)
...Show More Authors

Abstract:

        The research sought to identify the crises that occurred during the research period and their reflection on the performance of the hotel Research sample as well as to identify the reality of auditing the hotel Research sample and the preparation of a performance audit program can be adopted in auditing the performance of hotels in light of crises, and the problem of the research lies in the lack of a program to audit the performance of hotels that takes into account the crises experienced by the hotel sector, The research was based on solving its problems on three hypotheses, the first is that the performance audit in light of the Covid-19 pand

... Show More
View Publication Preview PDF