A reliable and environmental analytical method was developed for the direct determination of tetracycline using flow injection analysis (FIA) and batch procedures with spectrophotometric detection. The developed method is based on the reaction between a chromogenic reagent (vanadium (III) solution) and tetracycline at room temperature and in a neutral medium, resulting in the formation of an intense brown product that shows maximum absorption at 395 nm. The analytical conditions were improved by the application of experimental design. The proposed method was successfully used to analyze samples of commercial medications and verified throughout the concentration ranges of 25–250 and 3–25 µg/mL for both FIA and batch procedures, respecti
... Show MoreBackground: Periodontal diseases (PD) are inflammatory conditions of the tissues supporting the teeth, most often gingivitis and periodontitis. Maxillary chronic rhinosinusitis (MCRS) is the inflammation of the maxillary sinuses which is last for at least 12 consecutive weeks duration. Aims of study: Distribution of periodontal diseases among patients with Maxillary chronic rhinosinusitis according to gender and age. Materials and methods: Males and females subjects (25-45 years), divided into two groups; 150 patients suffer from MCRS and 130 subjects without MCRS. Clinical periodontal parameters; Plaque Index (PL.I), Gingival Index (G.I), Probing Pocket Depth (PPD), Clinical Attachment Level (CAL) and Bleeding On Probing (BOP) recorded f
... Show MoreAspartate aminotransferase was purified from urine and serum of patients with type 2 diabetes in a 2 steps procedure involving dialysis bag and sephadex G-25 gel filtration (column chromatography). The enzyme was purified 346.23 fold with 1467% yield and 3.46 fold with 142.85% yield in urine and serum of patients with type 2 diabetes respectively. The purified enzyme showed single peak. The results of this study revealed that AST activity of type 2 diabetes urine and serum increased significantly (p<0.001) compared with control group.
This work is concerned with the vibration attenuation of a smart beam interacting with fluid using proportional-derivative PD control and adaptive approximation compensator AAC. The role of the AAC is to improve the PD performance by compensating for unmodelled dynamics using the concept of function approximation technique FAT. The key idea is to represent the unknown parameters using the weighting coefficient and basis function matrices/vectors. The weighting coefficient vector is updated using Lyapunov theory. This controller is applied to a flexible beam provided with surface bonded piezo-patches while the vibrating beam system is submerged in a fluid. Two main effects are considered: 1) axial stretching of the vibrating beam that leads
... Show MoreThis study aims to investigate the academic leaders’ perceptions towards the degree of availability of the dimensions of organizational immunity systems at the University of Tabuk, as well as to reveal the statistically significant differences between the average responses of the study sample members about the degree of availability of these dimensions at their university due to the variables of (gender, leadership position, and college specialization). To achieve the objectives of the study, a descriptive survey method was used. The study population consisted of (200) male and female leaders who were academic leaders at the University of Tabuk. A questionnaire was used as a tool for collecting data, which its validity and reliability
... Show MoreA simple, rapid and environmentally friendly dispersive liquid–liquid microextraction method-based spectrophotometric method for the trace determination of folic acid has been developed. The proposed method is based on the formation of a deep yellow product via reaction of folic acid and 1,2-naphthoquine-4-sulfonate at pH = 9. The formed complex was extracted using a mixture of chloroform and ethanol. Then, the tiny organic droplets were measured at λ = 520 nm. At the optimum conditions, linearity was ranged from 0.05 to 1.5 μg/mL for the standard and samples, with a linear correlation coefficient of 0.9996. The detection limits were 0.02, 0.027, 0.03, 0.02 and 0.04 μg/mL for standard, tablet (5 mg), tablet (1 mg), syrup and fl
... Show MoreVariable-Length Subnet Masks (VLSM), often referred to as "subnetting a subnet", is used to maximize addressing efficiency. The network administrator is able to use a long mask on networks with few hosts, and a short mask on subnets with many hosts. This addressing scheme allows growth and does not involve wasting addresses. VLSM gives a way of subnetting a network with
minimal loses of IP addresses for a specific range. Unfortunately, the network administrator has to perform several mathematical steps (or use charts) to get the required results from VLSM. In this paper, a simple graph simulator is proposed (using Visual Basic 6.0 Language) to perform all the required mathematical steps and to display the obtained required informatio
Variable-Length Subnet Masks (VLSM), often referred to as "subnetting a subnet", is used to maximize addressing efficiency. The network administrator is able to use a long mask on networks with few hosts, and a short mask on subnets with many hosts. This addressing scheme allows growth and does not involve wasting addresses. VLSM gives a way of subnetting a network with minimal loses of IP addresses for a specific range. Unfortunately, the network administrator has to perform several mathematical steps (or use charts) to get the required results from VLSM. In this paper, a simple graph simulator is proposed (using Visual Basic 6.0 Language) to perform all the required mathematical steps and to display the obtained required information (the
... Show More