This study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices and subsequently optimized using Particle Swarm Optimization (PSO) and the Cheetah Optimizer (CO). The optimized controllers are referred to as PSO-PID and CO-PID, respectively. The error standard used for the electro-hydraulic elevator control system is the Integral Time-weighted Absolute Error (ITAE) type. This study addresses the need to improve dynamic performance and control accuracy in electro-hydraulic elevator systems under maximum load conditions. Experimental results obtained under a 30 kg load for the displacement response showed that PSO-PID reduced rise time by 36.8% and settling time by approximately 37.2% while improving steady-state accuracy by nearly 80% compared with the conventional PID. The CO-PID controller further improved performance, achieving additional reductions of 13.6% in rise time and 13.8% in settling time relative to PSO-PID, as well as decreasing steady-state error by 37.5%. Overall, CO-PID achieved substantial reductions in rise and settling times (up to 45.4% and 45.7%, respectively) and improved steady-state accuracy by nearly 87% compared with the traditional PID. In pressure control loops, PSO-PID reduced settling time by up to 12.8%, whereas CO-PID achieved up to 16.4% faster stabilization relative to the conventional PID. The experimental results were in agreement with the developed MATLAB/Simulink model, confirming the high accuracy of the simulation in representing the system dynamics. These findings demonstrate the superior responsiveness, stability, and efficiency of the CO-PID controller for electro-hydraulic elevator applications.
In this study, a one-dimensional model represented by Butler-Volmer-Monod (BVM) model was proposed to compute the anode overpotential and current density in a mediator-less MFC system. The system was fueled with various organic loadings of real field petroleum refinery oily sludge to optimize the favorable organic loading for biomass to operate the suggested system. The increase in each organic loading showed higher resistance to electrons transport to the anode represented by ohmic loss. On the contrary, both activation and mass transfer losses exhibited a noticeable decrement upon the increased organic loadings. However, current density was improved throughout all increased loads achieving a maximum current density of 5.2 A/m3
... Show MoreThe aim of this paper is to design a PID controller based on an on-line tuning bat optimization algorithm for the step-down DC/DC buck converter system which is used in the battery operation of the mobile applications. In this paper, the bat optimization algorithm has been utilized to obtain the optimal parameters of the PID controller as a simple and fast on-line tuning technique to get the best control action for the system. The simulation results using (Matlab Package) show the robustness and the effectiveness of the proposed control system in terms of obtaining a suitable voltage control action as a smooth and unsaturated state of the buck converter input voltage of ( ) volt that will stabilize the buck converter sys
... Show MoreWind turbine (WT) is now a major renewable energy resource used in the modern world. One of the most significant technologies that use the wind speed (WS) to generate electric power is the horizontal-axis wind turbine. In order to enhance the output power over the rated WS, the blade pitch angle (BPA) is controlled and adjusted in WT. This paper proposes and compares three different controllers of BPA for a 500-kw WT. A PID controller (PIDC), a fuzzy logic controller (FLC) based on Mamdani and Sugeno fuzzy inference systems (FIS), and a hybrid fuzzy-PID controller (HFPIDC) have been applied and compared. Furthermore, Genetic Algorithm (GA) and Particle swarm optimization (PSO) have been applied and compared in order to identify the
... Show MoreThe aerodynamic characteristics of the forward swept wing aircraft have been studied theoretically and experimentally. Low order panel method with the Dirichlet boundary condition have been used to solve the case of the steady, inviscid and compressible flow. Experimentally, a model was manufactured from wood to carry out the tests. The primary objective of the experimental work was the measurements of the wake dimensions and orientation, velocity defect along the wake and the wake thickness. A blower type low speed (open jet) wind tunnel was used in the experimental work. The mean velocity at the test section was (9.3 m/s) and the Reynolds number based on the mean aerodynamic chord and the mean velocity was (0.46x105). The measurements sho
... Show MoreAs one type of heating furnaces, the electric heating furnace (EHF) typically suffers from time delay, non-linearity, time-varying parameters, system uncertainties, and harsh en-vironment of the furnace, which significantly deteriorate the temperature control process of the EHF system. In order to achieve accurate and robust temperature tracking performance, an integration of robust state feedback control (RSFC) and a novel sliding mode-based disturbance observer (SMDO) is proposed in this paper, where modeling errors and external disturbances are lumped as a lumped disturbance. To describe the characteristics of the EHF, by using convection laws, an integrated dynamic model is established and identified as an uncertain nonlinear second ord
... Show MoreObjective. Glass-ionomer and resin-modified glass-ionomer cements are versatile materials with the ability to form a direct bond with tooth tissues. The aim of this study was to formulate a novel class of dental bio-interactive restorative material (pRMGIC) based on resin-modified glass-ionomer cements via the inclusion of an organophosphorus monomer, ethylene glycol methacrylate phosphate, with a potential to improve the mechanical properties and also function as a reparative restorative material. Methods. pRMGIC was formulated with modification of the resin phase by forming mixes of ethylene glycol methacrylate phosphate (EGMP; 0–40%wt) and 2-hydroxyethyl methacrylate monomer into the liquid phase of a RMGIC (Fuji II LC, GC Corp.).
... Show MoreBackground: Vitamin D improves innate immunity by enhancing the expression of antimicrobial peptides. The antimicrobial action of cathelicidin is widespread and effective against cariogenic bacteria. This research aimed to investigate the effect of vitamin D deficiency on the level of salivary cathelicidin concerning dental caries experience.
Subjects and Methods: A case-control study was carried out, and the sample was composed of 80 females; the study group involved 40 females with a serum vitamin D concentration of less than 10 ng/ml. In addition to the control group involving 40 females wh
... Show MoreIn this study used three methods such as Williamson-hall, size-strain Plot, and Halder-Wagner to analysis x-ray diffraction lines to determine the crystallite size and the lattice strain of the nickel oxide nanoparticles and then compare the results of these methods with two other methods. The results were calculated for each of these methods to the crystallite size are (0.42554) nm, (1.04462) nm, and (3.60880) nm, and lattice strain are (0.56603), (1.11978), and (0.64606) respectively were compared with the result of Scherrer method (0.29598) nm,(0.34245),and the Modified Scherrer (0.97497). The difference in calculated results Observed for each of these methods in this study.
In this paper, a novel flow control strategy which is the inlet throttled pump was used to design an angular velocity control system for rotary actuator. Inlet throttled systems have good performance in addition to their high efficiency compared to traditional valve-controlled systems. The flow in the proposed system is adjusted by a valve that is positioned at the pump inlet with the purpose of reducing the energy loses across the valve. This regulated flow is used then to control the actuator angular velocity. The system was modeled and the open loop stability and performance were studied. In order to improve the system performance, proportional-integral-derivative (PID) and H-infinity controllers have been designed. The multiplicative un
... Show More