This study presents the design, modeling, and experimental evaluation of a three-level electro-hydraulic elevator system controlled by a Delta DVP-20SX2 Programmable Logic Controller (PLC) equipped with an integrated Proportional–Integral–Derivative (PID) module. The PLC, programmed in Ladder Logic using ISPSoft 2.46, regulates cabin motion across all three levels. A detailed MATLAB/Simulink model was developed, incorporating three PID controllers: one for displacement regulation via a proportional directional control valve and two for dynamic pressure regulation using a proportional pressure relief valve. Conventional PID parameters were initially tuned using the trial-and-error method based on time-domain performance indices and subsequently optimized using Particle Swarm Optimization (PSO) and the Cheetah Optimizer (CO). The optimized controllers are referred to as PSO-PID and CO-PID, respectively. The error standard used for the electro-hydraulic elevator control system is the Integral Time-weighted Absolute Error (ITAE) type. This study addresses the need to improve dynamic performance and control accuracy in electro-hydraulic elevator systems under maximum load conditions. Experimental results obtained under a 30 kg load for the displacement response showed that PSO-PID reduced rise time by 36.8% and settling time by approximately 37.2% while improving steady-state accuracy by nearly 80% compared with the conventional PID. The CO-PID controller further improved performance, achieving additional reductions of 13.6% in rise time and 13.8% in settling time relative to PSO-PID, as well as decreasing steady-state error by 37.5%. Overall, CO-PID achieved substantial reductions in rise and settling times (up to 45.4% and 45.7%, respectively) and improved steady-state accuracy by nearly 87% compared with the traditional PID. In pressure control loops, PSO-PID reduced settling time by up to 12.8%, whereas CO-PID achieved up to 16.4% faster stabilization relative to the conventional PID. The experimental results were in agreement with the developed MATLAB/Simulink model, confirming the high accuracy of the simulation in representing the system dynamics. These findings demonstrate the superior responsiveness, stability, and efficiency of the CO-PID controller for electro-hydraulic elevator applications.
Artificial pancreas is simulated to handle Type I diabetic patients under intensive care by automatically controlling the insulin infusion rate. A Backstepping technique is used to apply the effect of PID controller to blood glucose level since there is no direct relation between insulin infusion (the manipulated variable) and glucose level in Bergman’s system model subjected to an oral glucose tolerance test by applying a meal translated into a disturbance. Backstepping technique is usually recommended to stabilize and control the states of Bergman's class of nonlinear systems. The results showed a very satisfactory behavior of glucose deviation to a sudden rise represented by the meal that increase the blood glucose
... Show More
In this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these
... Show MoreIn this work, an efficient energy management (EEM) approach is proposed to merge IoT technology to enhance electric smart meters by working together to satisfy the best result of the electricity customer's consumption. This proposed system is called an integrated Internet of things for electrical smart meter (2IOT-ESM) architecture. The electric smart meter (ESM) is the first and most important technique used to measure the active power, current, and energy consumption for the house’s loads. At the same time, the effectiveness of this work includes equipping ESM with an additional storage capacity that ensures that the measurements are not lost in the event of a failure or sudden outage in WiFi network. Then then these measurement
... Show MoreEarly diagnosis and clinical decision-making depend on accurate brain tumor classification using magnetic resonance imaging (MRI). However, traditional deep learning methods usually rely on centralized medical data, which raises privacy concerns and limits the use of distributed clinical data. This research proposes a privacy-preserving federated learning framework for MRI image-based binary brain tumor classification using a decentralized ResNet-18 architecture that enables collaborative training without sharing raw patient data. To reflect realistic clinical conditions, the framework integrates heterogeneous multi-source datasets in different image formats (PNG and JPG) and evaluates performance under both IID and non-IID settings
... Show MoreCNC machine is used to machine complex or simple shapes at higher speed with maximum accuracy and minimum error. In this paper a previously designed CNC control system is used to machine ellipses and polylines. The sample needs to be machined is drawn by using one of the drawing software like AUTOCAD® or 3D MAX and is saved in a well-known file format (DXF) then that file is fed to the CNC machine controller by the CNC operator then that part will be machined by the CNC machine. The CNC controller using developed algorithms that reads the DXF file feeds to the machine, extracts the shapes from the file and generates commands to move the CNC machine axes so that these shapes can be machined.
Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the sola
... Show MoreThis paper features the modeling and design of a pole placement and output Feedback control technique for the Active Vibration Control (AVC) of a smart flexible cantilever beam for a Single Input Single Output (SISO) case. Measurements and actuation actions done by using patches of piezoelectric layer, it is bonded to the master structure as sensor/actuator at a certain position of the cantilever beam.
The smart structure is modeled based on the concept of piezoelectric theory, Bernoulli -Euler beam theory, using Finite Element Method (FEM) and the state space techniques. The number of modes is reduced using the controllability and observability grammians retaining the first three
dominant vibratory modes, and for the reduced syste