Urinary tract infection (UTI) is a considerable problem aecting the health of people each year. It is caused by various Gram-positive (G+ve) and Gram-negative (G-ve) pathogens. It is an important illness in the world aecting all age groups across their life span. Objectives: To identify the most common aerobic bacteria that cause UTIs and their antibiotic susceptibility and antimicrobial activity of plant extracts of the males' patients. Materials and methods: The study involved 35 midstream urine samples from the male students (University of Baghdad, Baghdad, Iraq) with suspicious symptoms of UTI, during the period from January-March 2018. Each urine sample was cultured rst on Mannitol Salt Agar and MacConkey agar plates to dierentiate between G+ve and -ve bacteria. The isolated bacteria were subjected to certain antibiotics and 100% plant extract oils. Results: Out of 35 urine samples, there were 62 isolates. There were 34 (54.8%) G-ve and 28 (45.2%) G+ve pathogens. Staph. epidermidis (n=17, 27.4%) was the most common isolated pathogen, while P. aeruginosa (n=5, 8.1%) was the least isolated organism. Vancomycin was the most sensitive antibiotic for the Staph. epidermidis (52.9%) and Staph. epidermidis (45.5%). While oregano oil was more sensitive to Staph. epidermidis and Staph. aureus in 64.7% and 63.6% respectively. Imipenem was the most eective antibiotic for the three common G-ve isolates E. coli, K. Pneumoniae, and Enterobacter spp in 83.3%, 90%, and 85.7% respectively. Oregano oil was the most susceptible plant extract for E. coli (91.7%). Conclusion: Plants oils are potentially a good source of antimicrobial agents. Besides, the plant extract oils are cheaper than antibiotics. Therefore, they could be used in UTI medicine.
Lightweight concrete-filled tube (CFST) columns offer numerous benefits, such as reduced weight, enhanced resistance to buckling, improved structural performance, and the ability to endure cyclic loading. This study considered key research on the structural behavior of CFST columns, covering various topics, including lightweight concrete, methods of concrete placement within steel tubes, and CFST columns with and without shear connectors. The literature review reveals that while several researchers have explored the use of shear connectors as a load-transfer mechanism in CFST columns, there is no consensus on the design methodology for connector resistance. Shear connectors signifi
In-situ gelation is a process of gel formation at the site of application, in which a drug product formulation that exists as a liquid has been transformed into a gel upon contact with body fluids. As a drug delivery agent, the in-situ gel has an advantage of providing sustained release of the drug agent. In-situ gelling liquid suppositories using poloxamer 188 (26-30% W/W) as a suppository base with 10% W/W naproxen were prepared, the gelation temperature of these preparations were measured and they were all above the physiological temperature. Additives such as polyvinylpyrrolidin "PVP" ,hydroxylpropylmethylcellulose "HPMC", sodium alginate and sodium chloride were used in concentration ranging from (0.25-1
... Show Moreto evaluate the effect of various Nd:YAG frequency doubled laser parameters on the acid
dissolution and the progression of in vitro caries like lesions in human enamel.
Materials and Methods: Human extracted caries free upper first premolar teeth were collected for
this study. The irradiated teeth were divided into two groups. The first group was irradiated with
continuous Nd:YAG laser radiation, and the second group was irradiated with chopped Nd:YAG laser
radiation. For the first group, power and exposure time were changed while for the second group
power and number of pulses were changed. The spot diameter was kept constant for all the samples.
Results: using 1.5 W and 3 seconds (exposure time), best results among
A mathematical model has been formulated to predict the influence of high outdoor air temperature on the performance of small scale air - conditioning system using R22 and alternative refrigerants R290, R407C, R410A. All refrigerants were investigated in the cooling mode operation. The mathematical model results have been validated with experimental data extracted from split type air conditioner of 2 TR capacity. This entailed the construction of an experimental test rig which consists of four main parts. They are, the refrigeration system, psychrometric test facility, measuring instrumentation, and auxiliary systems. The conditioned air was maintained at 25 0C dry bulb and 19 0C wet bulb for all tests. The outdoor ambient air temperatur
... Show MoreAbstract
Objective(s): To evaluate blended learning in nursing education at the Middle Region in Iraq.
Methodology: A descriptive study, using evaluation approach, is conducted to evaluate blended learning in nursing education in Middle Region in Iraq from September 26th, 2021 to March 22nd, 2022. The study is carried out at two Colleges of Nursing at the University of Baghdad and University of Tikrit in Iraq. A convenient, non-probability, sample of (60) undergraduate nursing students is selected. The sample is comprised of (30) student from each college of nursing, Self-report questionnaire is constructed from the literature, for e
... Show More