Urinary tract infection (UTI) is a considerable problem aecting the health of people each year. It is caused by various Gram-positive (G+ve) and Gram-negative (G-ve) pathogens. It is an important illness in the world aecting all age groups across their life span. Objectives: To identify the most common aerobic bacteria that cause UTIs and their antibiotic susceptibility and antimicrobial activity of plant extracts of the males' patients. Materials and methods: The study involved 35 midstream urine samples from the male students (University of Baghdad, Baghdad, Iraq) with suspicious symptoms of UTI, during the period from January-March 2018. Each urine sample was cultured rst on Mannitol Salt Agar and MacConkey agar plates to dierentiate between G+ve and -ve bacteria. The isolated bacteria were subjected to certain antibiotics and 100% plant extract oils. Results: Out of 35 urine samples, there were 62 isolates. There were 34 (54.8%) G-ve and 28 (45.2%) G+ve pathogens. Staph. epidermidis (n=17, 27.4%) was the most common isolated pathogen, while P. aeruginosa (n=5, 8.1%) was the least isolated organism. Vancomycin was the most sensitive antibiotic for the Staph. epidermidis (52.9%) and Staph. epidermidis (45.5%). While oregano oil was more sensitive to Staph. epidermidis and Staph. aureus in 64.7% and 63.6% respectively. Imipenem was the most eective antibiotic for the three common G-ve isolates E. coli, K. Pneumoniae, and Enterobacter spp in 83.3%, 90%, and 85.7% respectively. Oregano oil was the most susceptible plant extract for E. coli (91.7%). Conclusion: Plants oils are potentially a good source of antimicrobial agents. Besides, the plant extract oils are cheaper than antibiotics. Therefore, they could be used in UTI medicine.
In this research, Fuzzy Analytic Hierarchy Process technique is applied (Fuzzy AHP) which is one of multi-criteria decision making techniques to evaluate the criteria for urban planning projects, the project of developing master plan of Al-Muqdadiyah city to 2035 has been chosen as a case study. The researcher prepared a list of criteria in addition to the authorized departments criteria and previous researches in order to choose optimized master plan according to these criteria. This research aims at employing the foundations of (Fuzzy AHP) technique in evaluating urban planning criteria precisely and flexible. The results of the data analysis to the individuals of the sample who are specialists, in this aspect. The la
... Show More
The aim of this paper is to determine the flexural moment capacity of Reactive Powder Concrete (RPC) two-way slabs based on three models proposed by previous studies (Model 1, Model 2, and Model 3). The results obtained from these models were compared with those obtained from experimental work to check the accuracy and the applicability of the adopted theoretical models. The experimental program included the testing of three simply supported RPC two-way slabs (1000x1000x70) mm each. The tested specimens had identical properties except their steel fibres volume ratios (0.5 %, 1 %, and 1.5 %). The comparison with the experimental data showed that (Model 3) is the most suitable one among the three models. Model 1 was found to underestimate the
... Show MoreThe study examined the assessment of raw water and drinking water projects of Diyala Governorate for the year 2017, amounting to (24) projects, The average per capita supply of potable water (0.396 m3 / day/person), which is less than the global standard for the average per capita of drinking water, and constitute water rumors within the network of water transport in the province (3%), and the water of raw and drinking value within the limits allowed to be used by Iraq and the global indicators of {Total acidity, alkaline, acidic function, chlorides, magnesium, Electrical conductivity, total soluble salts, sodium, potassium, sulfates, turbidity other than (raw water)}. While the index of calcium only a value higher than the limits
... Show MoreThe present work provides to treat real oily saline wastewater released from drilling oil sites by the use of electrocoagulation technique. Aluminum tubes were utilized as electrodes in a concentric manner to minimize the concentrations of 113400 mg TDS/L, 65623 mg TSS/L, and the ions of 477 mg HCO3/L, 102000 mg Cl/L and 5600 mg Ca/L presented in real oily wastewater under the effect of the operational parameters (the applied current and reaction time) by making use of the central composite rotatable design. The final concentrations of TDS, TSS, HCO3, Cl, and Ca that obtained were 93555 ppm (17.50%), 11011 ppm (83.22%), 189ppm (60.38%), 80000ppm (22%), and 4200 ppm (25%), respectively, under the optimum values of the operational parameters
... Show More