Preferred Language
Articles
/
d4Yv1YYBIXToZYALmrX1
Phase Change Process in a Zigzag Plate Latent Heat Storage System during Melting and Solidification
...Show More Authors

Applying a well-performing heat exchanger is an efficient way to fortify the relatively low thermal response of phase-change materials (PCMs), which have broad application prospects in the fields of thermal management and energy storage. In this study, an improved PCM melting and solidification in corrugated (zigzag) plate heat exchanger are numerically examined compared with smooth (flat) plate heat exchanger in both horizontal and vertical positions. The effects of the channel width (0.5 W, W, and 2 W) and the airflow temperature (318 K, 323 K, and 328 K) are exclusively studied and reported. The results reveal the much better performance of the horizontal corrugated configuration compared with the smooth channel during both melting and solidification modes. It is found that the melting rate is about 8% faster, and the average temperature is 4 K higher in the corrugated region compared with the smooth region because of the large heat-exchange surface area, which facilitates higher rates of heat transfer into the PCM channel. In addition to the higher performance, a more compact unit can be achieved using the corrugated system. Moreover, applying the half-width PCM channel accelerates the melting rate by eight times compared to the double-width channel. Meanwhile, applying thicker channels provides faster solidification rates. The melting rate is proportional to the airflow temperature. The PCM melts within 274 s when the airflow temperature is 328 K. However, the melting time increases to 460 s for the airflow temperature of 308 K. Moreover, the PCM solidifies in 250 s and 405 s in the cases of 318 K and 328 K airflow temperatures, respectively.

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Oct 01 2011
Journal Name
Journal Of Engineering
SOLAR WATER HEATER WITH SHELL AND HELICAL COILED TUBE HEAT EXCHANGER AS A STORAGE TANK
...Show More Authors

In this work an experimental study is performed to evaluate the thermal performance
of locally made closed loop solar hot water system using a shell and helical coiled tube
heat exchanger as a storage tank. Several measurements are taken include inlet and outlet
temperatures of both collectors and supply water and temperature distribution within the
storage tank. This is beside the water flow rate in both collectors and load cycle. The
main parameters of the system are obtained.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Dec 31 2022
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
AREAS OF ORGANIZATIONAL CHANGE AND THEIR IMPACT ON THE STRATEGIC MARKETING PLANNING PROCESS: AREAS OF ORGANIZATIONAL CHANGE AND THEIR IMPACT ON THE STRATEGIC MARKETING PLANNING PROCESS
...Show More Authors

ABSTRACT

            The aim of the research is to identify the impact of the areas of organizational change in strategic marketing planning in cement factories operating within the city of Al-Khums, and this effect was measured using a questionnaire consisting of 28 phrases, and it was relied on the descriptive approach that suits the nature of the subject of the research, while the research community consists of heads And members of the board of directors, authorized managers, unit managers and heads of departments in the factories under study, which numbered 55 respondents, during the month of September of the year 2021, and a sample of the compreh

... Show More
View Publication Preview PDF
Publication Date
Thu Oct 25 2018
Journal Name
Journal Of Economics And Administrative Sciences
Reflection of the change process in enhancing organizational performance (Analytical research)
...Show More Authors

  This research aims to test the relation and effect of the process of organizational change as an independent variable (change in human resources, technological change, change in tasks, change in organizational structure) in organizational performance as a variable of success (financial performance, operational performance, customer satisfaction, growth). And learning) in the Office of the province of Baghdad, as well as determine the existence of differences of statistical significance between the variables of research, and then try to come out with a set of recommendations to contribute to the strengthening of organizational performance, and carried out this research on the eye of the vertical number (75) individuals, The

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Dec 31 2012
Journal Name
Al-khwarizmi Engineering Journal
Experimental Study on the Impact of External Geometrical Shape on Free and Forced Convection Time Dependent Average Heat Transfer Coefficient during Cooling Process
...Show More Authors

In this research, an experimental study was conducted to high light the impact of the exterior shape of a cylindrical body on the forced and free convection heat transfer coefficients when the body is hold in the entrance of an air duct. The impact of changing the body location within the air duct and the air speed are also demonstrated. The cylinders were manufactured with circular, triangular and square sections of copper for its high thermal conductivity with appropriate dimensions, while maintaining the surface area of all shapes to be the same. Each cylinder was heated to a certain temperature and put inside the duct at certain locations. The temperature of the cylinder was then monitored. The heat transfer coefficient were then cal

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 23 2021
Journal Name
International Journal Of Energy Research
Localized heating element distribution in composite metal foam‐phase change material: Fourier's law and creeping flow effects
...Show More Authors

View Publication
Scopus (40)
Crossref (39)
Scopus Clarivate Crossref
Publication Date
Thu Jan 31 2019
Journal Name
Journal Of Engineering
Experimental Study on Double-Pass Solar Air Heater with and without using Phase Change Material
...Show More Authors

In this paper, an experimental study was conducted to enhance the thermal performance of a double-pass solar air heater (SAH) using phase change material (PCM) for thermal storage at climatic conditions of Baghdad city - Iraq. The double-pass solar air heater integrated with thermal storage system was manufactured and tested to ensure that the air heating reserved after the absence of the sun. The rectangular cavity filled with paraffin wax was used as a latent heat storage and incorporated into the lower channel of solar air heater. Experiments were carried out to evaluate the charging and discharging characteristics of two similar designed solar air collectors with and without using phase change material at a constant

... Show More
View Publication Preview PDF
Crossref (24)
Crossref
Publication Date
Fri Jul 01 2016
Journal Name
Agricultural Engineering
The Change in Spectrum of Drops in the Exploitation Process of Agricultural Nozzles
...Show More Authors
Abstract<p>Agricultural nozzles usually produce a different drops size depending on the pressure and the physical condition (work life) of the nozzle besides producing a wide range of the drops spectrum in the spray cloud. In this paper the standard flat fan nozzles were investigated regarding the effect of the working pressure and the nozzle physical condition (new and worn nozzles). The size of drops and the spectrum of drops across the long axis of the spray pattern were examined by using Sympatec GmbH Laser Diffraction. Reducing the working pressure from 3 to 2 and then to 1 caused production of larger drops, also using worn nozzles (especially with lower pressure) changed the drops size whi</p> ... Show More
View Publication
Crossref
Publication Date
Sat Nov 08 2025
Journal Name
Iraqi Journal Of Science
UNSTEADY PRESSURE DROP AND HEAT TRANSFER OFMAGNETOHYDRODYNAMIC ANNULAR TWO-PHASE INRECTANGULAR CHANNEL
...Show More Authors

An annular two-phase, steady and unsteady, flow model in which a conductingfluid flow under the action of magnetic field is concavely. Two models arepresented, in the model one; the magnetic field is perpendicular to the long side ofthe channel, while in the model two is perpendicular to the short side. Also, westudy, to some extent the single-phase liquid flow.It is found that the motion and heat transfer equations are controlled by differentdimensionless parameters namely, Reynolds, Hartmann, Prandtl, and Poiseuilleparameters. The Laplace transform technique is used to solve each of the motion andheat transfer equations. The effects of each of dimensionless parameters upon thevelocity and heat transfer is analyzed.A comprehensive study fo

... Show More
View Publication Preview PDF
Publication Date
Mon Aug 01 2016
Journal Name
Journal Of Engineering
Performance Evaluation of the Investment Projects during the Implementation Phase (Najaf province as a case study)
...Show More Authors

The construction project is a very complicated work by its nature and requires specialized knowledge to lead it to success. The construction project is complicated socially, technically and economically in its planning, management and implementation aspects due to the fact that it has many variables and multiple stakeholders in addition to being affected by the surrounding environment. Successful projects depend on three fundamental points which are cost-time, performance and specifications. The project stakeholder's objective to achieve best specifications and the cost-time frame stipulated in the contract.

The question is, was the optimum implementation accomplished? The provision for the success of the project

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 13 2019
Journal Name
Al-khwarizmi Engineering Journal
Transient Behavior Analysis for Solar Energy Storage in PCM-CFM Material Using Equivalent Heat Capacity Method as Storage Model
...Show More Authors

A paraffin wax and copper foam matrix were used as a thermal energy storage material in the double passes air solar chimney (SC) collector to get ventilation effect through daytime and after sunset. Air SC collector was installed in the south wall of an insulated test room and tested with different working angles (30o, 45o and 60o). Different SC types were used; single pass, double passes flat plate collector and double pass thermal energy storage box collector (TESB). A computational model based on the finite volume method for transient tw dimensional domains was carried out to describe the heat transfer and storage in the thermal energy storage material of collector. Also, equivalent specific heat metho

... Show More
View Publication Preview PDF
Crossref (3)
Crossref