Preferred Language
Articles
/
cxfZ_o0BVTCNdQwCPizj
Rapid determination of thiabendazole in juice by SERS coupled with novel gold nanosubstrates
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sun Sep 04 2011
Journal Name
Baghdad Science Journal
Determination of Uranium Concentration in Sheep Organs for Some Iraqiۥs Cities
...Show More Authors

The aim of this research is to determine the uranium concentration and its distribution in many sheep organs that live in different region of Iraq. The uranium concentration in tissue samples is measured by using fission tracks registration in CR-39 detector that caused by the bombardment of U235 with thermal neutrons from (241Am-Be) neutron source of thermal flux (5x 103 n.cm-2. s-1). The results show that the maximum uranium concentration in bronchiole tissues of the animals was found in Karbala city (3.706ppm) while the minimum concentration (0.127 ppm) was found in Al-Faluja city, also the same result in lung tissue the maximum value was found in Karbala city (2.313ppm) and the minimum concentration in Al Fluja (0.082). Otherwise,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2021
Journal Name
Annals Of Tropical Medicine And Public Health
SPECTROPHOTOMETRIC DETERMINATION OF DIPHENHYDRAMINE HCL IN PURE AND PHARMACEUTICAL FORMULATIONS USING THYMOL BLUE
...Show More Authors

This approach was developed to achieve an accurate, fast, economic and sensitivity to estimation of diphenhydramine Hydrochloride. The dye that produced via reaction between diphenhydramine HCl with thymol blue in acidic medium pH ≈ 4.0. The ion pair method include an optimization study to formed yellowcolored that extraction by liquid – liquid method. The product separated of complexes by using by chloroform solution measured spectrophotometry at 400 nm. The analysis data at optimum conditions showed that linearity concentration in a range of calibration curve 1.0 – 50 μg /mL, limit of detectionand limit of quantification 0.0786 and 0.2358 μg/mL respectively. The molar absorptivity and Sandell’s sensitivity were 1.8 × 10 -4 L/mo

... Show More
View Publication
Crossref
Publication Date
Sun Jun 03 2018
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Sulphite in Various Water Samples Via Chromium-1,5-Diphenylcarbazide Complex
...Show More Authors

A simple and rapid spectrophotometric method for the determination of sulphite SO3-2 is described. The method is based on the rapid reduction of known amount of chromate CrO4-2 in the presence of sulphite in acidic medium of 2N H2SO4. The amount of excess of chromate was measured after it reactions with 1,5-diphenylcarbazide which finally gives a pink-violet, water soluble and stable complex, which exhibit a maximum absorption at 542 nm. Beer's law was obeyed in the concentration range from 0.004-6.0 µg of sulphite in a final volume of 25 ml with a molar absorbtivity of 4.64×104 l.mol-1.cm-1, Sandal's sensitivity index of 0.001724 ?g .cm-2 and relative standard deviation of ±0.55 - ±0.83 depending on the concentration level. The present

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Tue Apr 01 2014
Journal Name
International Communications In Heat And Mass Transfer
Determination of a time-dependent thermal diffusivity and free boundary in heat conduction
...Show More Authors

View Publication
Scopus (18)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Fri Sep 25 2020
Journal Name
International Journal Of Drug Delivery Technology
Simultaneous Determination of Trace Mefenamic Acid in Pharmaceutical Samples via Flow Injection Fluorometry
...Show More Authors

Mefenamic acid belongs to non-steroidal anti-inflammatory drugs that are used widely for the treatment of analgesia. Our aim from this study is to establish a new assay for the quantitative determination of mefenamic acid (MFA) in the pharmaceutical sample by two sensitive and rapid flow injection-fluorometric methods. A homemade fluorometer was used in fluorescence measurements, which using solid-state laser diode 405 and 532 nm as a source, combined with a continuous flow injection technique. The first method depends on the effect of MFA on calcein blue (CLB) fluorescence at 405 nm. Another method is a study of rhodamine-6G (Rh-6G) fluorescence after adding MFA, and recording at 532 nm. Optimum parameters as fluorescent dye concen

... Show More
View Publication
Scopus (5)
Crossref (4)
Scopus Crossref
Publication Date
Tue Jun 15 2010
Journal Name
Journal Of Baghdad College Of Dentistry
Prosthodontist’s ability to detect parallelism of two lines used in occlusal plane determination
...Show More Authors

Background: Prosthodontists estimated the parallelism of the occlusal plane to different anatomical landmarks, which was somewhat arbitrary and depended mainly on their vision. The aim of this research was to assess the degree of accuracy of prosthodontists in determining the parallelism of two lines. This research was aimed to assess which technique would be more accurate for the prosthodontist to distinguish parallelism; the comparison of the occlusal plane with the interpupillary line or with the inferior border of the earlobes. Materials and methods: Twenty eight prosthodontic specialists were included in this research. Illustrations of two lines with different tilts were presented to the participants to distinguish whether parallel or

... Show More
Preview PDF
Publication Date
Wed Aug 23 2017
Journal Name
Journal Of Physics G: Nuclear And Particle Physics
Shell closures in Fl superheavy isotopes via determination of alpha decay preformation factor
...Show More Authors

View Publication
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Nov 21 2019
Journal Name
Journal Of Engineering
Automatic Determination of Liquid's Interface in Crude Oil Tank using Capacitive Sensing Techniques
...Show More Authors

The petroleum sector has a significant influence on the development of multiphase detection sensor techniques; to separate the crude oil from water, the crude oil tank is used. In this paper, a measuring system using a simple and low cost two parallel plate capacitance sensor is designed and implemented based on a Micro controlled embedded system plus PC to automatically identify the (gas/oil) and (oil/water) dynamic multi-interface in the crude oil tank. The Permittivity differences of two-phase liquids are used to determine the interface of them by measuring the relative changes of the sensor’s capacitance when passes through the liquid’s interface. The experiment results to determine the liquid’s interface is sa

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Sep 01 2013
Journal Name
Baghdad Science Journal
A sensitive spectrophotometric determination of tadalafil in pharmaceutical preparations and industrial wastewater samples
...Show More Authors

A simple, accurate, precise, rapid, economical and a high sensitive spectrophotometric method has been developed for the determination of tadalafil in pharmaceutical preparations and industrial wastewater samples, which shows a maximum absorbance at 204 nm in 1:1 ethanol-water. Beer's law was obeyed in the range of 1-7?g/ mL ,with molar absorptivity and Sandell ? s sensitivity of 0.783x105l/mol.cm and 4.97 ng/cm2respectively, relative standard deviation of the method was less than 1.7%, and accuracy (average recovery %) was 100 ± 0. 13. The limits of detection and quantitation are 0.18 and 0.54 µg .ml-1, respectively. The method was successfully applied to the determination of tadalafil in some pharmaceutical formulations

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Treatment of Simulated Carwash Wastewater by Electrocoagulation with Sonic Energy
...Show More Authors

Oily carwash wastewater is a high organic and chemical wastewater. This paper targeted to investigate a treatment to decrease the water consumption and contaminants in car-washing stations. Electrocoagulation combined with ultrasonic energy (Sono-Electrocoagulation) was suggested so that the carwash wastewater is treated to be reused. The effect of both the voltage and time of treatment on the removal of COD, turbidity, conductivity, and total dissolved solids (TDS) were studied at constant initial pH 7 and electrode distance 2 cm. The results showed the best results of removal COD, turbidity, TDS, and reduce electrical conductivity is when the voltage was 30 V and a treatment time of 90 minutes.

  <

... Show More
View Publication Preview PDF
Crossref (3)
Crossref