Abstract: Choosing suitable artificial teeth for partially edentulous patients and arranging these teeth in a way to look natural is difficult. An important factor in dentures construction is the mesiodistal width of anterior teeth, because a denture would not appearance natural if artificial teeth are of incorrect size. While for a successful orthodontic treatment, mesiodeistal width of teeth is important for space analysis and for establishing proper occlusion. The aim of this study is to determine the correlation between the average mesiodistal width of anterior and posterior teeth in male and female Iraqi population. 40 Iraqi subjects with normal occlusion participated in this study. Mesiodistal measurement of all teeth was carried out on stone cast. Obtained data was analyzed using SPSS 15 computer software. Mean and standard deviation were calculated for each variable. Comparisons between male and female samples were made for each variable using t-test. The average mesiodistal width of maxillary central incisor for male and female samples was (8.84 ± 0.46 and 8.58 ± 0.45, respectively).Mesiodistal width for mandibular central incisor for male and female samples was (5.46 ± 0.41 and 5.44 ± 0.24, respectively). These results are well within normal value for other ethnic groups. The ratio between maxillary and mandibular anterior and posterior teeth was also calculated. Mesiodistal width of anterior teeth and posterior teeth can be used as a guideline for choosing correct artificial teeth for partially edentulous patients and it is important for a good outcome in an orthodontic treatment.
We introduce a new class of harmonici multivalent functions define by generalized Rucheweyh derivative operator. We also obtain several interesting propertiesi such as sharp coefficienit estimates, distortioni bound, extreme points, Hadamardi product and other several results. Derivative; extreme points.
The main purpose of this work is the construction of an optical parametric amplifier (OPA) to generate a 629 nm pulsed laser. KTP nonlinear crystals were used for both parametric oscillation and amplification. A singly resonant parametric oscillator (OPO) is constructed to generate a signal of 1.54 μm and idler of 3.4 μm when the OPO system is pumped by 1.064 μm Q – switched Nd: YAG laser. The signal was then mixed with the pumping beam in OPA system to form the wanted wavelength. The obtained optical conversion efficiency was 60%.
Background : surface area anatomy is a proportional point to the retention of complete denture, in past there was no quantitative method to evaluate the surface area, nowadays the size and shape of maxillary arch is measured by different electronically and mathematical devices. A study was therefore, undertaken to measure surface area of upper dental cast that was taken by different final impressions. Materials and methods: twenty patients were examined. All of them had a healthy palate with no singe of injury, trauma, or deformity. Casts were taken by three different final impressions; zinc oxide, additional silicon, and poly ether. And two different devices were used; the computerized one and the Aluminum foil measure. Age, se
... Show MoreWater flow into unsaturated porous media is governed by the Richards’ partial differential equation expressing the mass conservation and Darcy’s laws. The Richards’ equation may be written in three forms,where the dependent variable is pressure head or moisture content, and the constitutive relationships between water content and pressure head allow for conversion of one form into the other. In the present paper, the “moisture-based" form of Richards’ equation is linearized by applying Kirchhoff’s transformation, which
combines the soil water diffusivity and soil water content. Then the similarity method is used to obtain the analytical solution of wetting front position. This exact solution is obtained by means of Lie’s
The aerodynamic characteristics of general three-dimensional rectangular wings are considered using non-linear interaction between two-dimensional viscous-inviscid panel method and vortex ring method. The potential flow of a two-dimensional airfoil by the pioneering Hess & Smith method was used with viscous laminar, transition and turbulent boundary layer to solve flow about complex configuration of airfoils including stalling effect. Viterna method was used to extend the aerodynamic characteristics of the specified airfoil to high angles of attacks. A modified vortex ring method was used to find the circulation values along span wise direction of the wing and then interacted with sectional circulation obtained by Kutta-Joukowsky the
... Show MoreThe sensors based on Nickel oxide doped chromic oxide (NiO: Cr2O3) nanoparticals were fabricated using thick-film screen printing of sol-gel grown powders. The structural, morphological investigations were carried out using XRD, AFM, and FESEM. Furthermore, the gas responsivity were evaluated towards the NH3 and NO2 gas. The NiO0.10: Cr2O3 nanoparticles exhibited excellent response of 95 % at 100oC and better selectivity towards NH3 with low response and recovery time as compared to pure Cr2O3 and can stand as reliable sensor element for NH3 sensor related applications.