Background & objective: Difficult intubation remains a risk for patients undergoing general anesthesia (GA) or mechanical ventilation in an intensive care unit (ICU). Macroglossia is a known factor for difficult intubation. But it is not routine to assess the tongue size to predict difficult intubation. Studies are found deficient in comparing usefulness of measuring thyromental distance and the tongue thickness (TT) measured by ultrasonography to estimate difficult intubation. We compared tongue thickness measured by ultrasonography and thyromental distance as a means to anticipate difficult intubation. Methodology: A convenient sample of 60 patients; 32 males and 28 females, who were undergoing elective surgery with GA were included. Thyro-mental distance (TMD), along with tongue thickness (TT) were measured consecutively in each patient in a transitional room. After induction of GA, Cormack Lehane (CL) score was assessed for all patients to detect difficult intubation. Results: Thyro-mental distance was significantly reduced in patients with difficult intubation, while the reverse was in the measurement of tongue thickness; where patients with difficult intubation had significantly a greater TT than those with no difficult intubation. TT measurement had significantly higher sensitivity and specificity (38%, and 96% respectively; P = 0.002) than thyro-mental distance in the detection of difficult intubation. Conclusion: In this study we demonstrated that there was statistically significant inverse relationship of thyro-mental distance on CL, and statistically significant direct relationship of tongue thickness on CL. The results showed that tongue thickness was more effective to detect difficult intubation. Abbreviations: CL - Cormack Lehane; TMD - Thyro-mental distance; TT - Tongue thickness; Keywords: Tongue Thickness; Thyromental Distance; Difficult Intubation Citation: Kadhim AB, Hamid GR. A comparative study between tongue thickness measured by ultrasonography and thyromental distance in anticipation of difficult intubation. Anaesth. pain intensive care 2024;28(3):431−435; DOI: 10.35975/apic.v28i3.2465 Received: March 16, 2024; Reviewed: March 29, 2024; Accepted: March 31, 2024
Background: For decades, the use of naturally accessible materials in treating human disease has been widespread. The goal of this study was to determine the anti-fungal effectiveness /of the lemongrass essential oil (LGEO) versus Candida albicans (C. albicans) adhesion to polymethylmethacrylate (PMMA) materials. Material and methods: LGEO's anti-fungal activity was tested against C. albicans adhesion using the following concentration of LGEO in PMMA monomer (2.5 vol. %, 5 vol. % LGEO) selected from the pilot study as the best two effective concentrations. A total of 40 specimens were fabricated for the candida adherence test and were subdivided into four equal groups: negative control 0 vol. % addition, experimental with 2.5 vol. % and
... Show MoreIn this study, the photodegradation of Congo red dye (CR) in aqueous solution was investigated using Au-Pd/TiO2 as photocatalyst. The concentration of dye, dosage of photocatalyst, amount of H2O2, pH of the medium and temperature were examined to find the optimum values of these parameters. It has been found that 28 ppm was the best dye concentration. The optimum amount of photocatalyst was 0.09 g/75 mL of dye solution when the degradation percent was ~ 96 % after irradiation time of 12 hours, while the best amount of hydrogen peroxide was 7μl/75 mL of dye solution at degradation percent ~97 % after irradiation time of 10 hours, whereas pH 5 was the best value to carry out the reaction at the highest degradation percent. In additio
... Show MoreA novel demountable shear connector for precast steel-concrete composite bridges is presented. The connector uses high-strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents bolts from slipping within their holes. Moreover, the connector promotes accelerated construction and overcomes the typical construction tolerance issues of precast structures. Most importantly, the connector allows bridge disassembly. Therefore, it can address different bridge deterioration scenarios with minimum disturbance to traffic flow including the following: (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (
... Show MoreThe temperature control process of electric heating furnace (EHF) systems is a quite difficult and changeable task owing to non-linearity, time delay, time-varying parameters, and the harsh environment of the furnace. In this paper, a robust temperature control scheme for an EHF system is developed using an adaptive active disturbance rejection control (AADRC) technique with a continuous sliding-mode based component. First, a comprehensive dynamic model is established by using convection laws, in which the EHF systems can be characterized as an uncertain second order system. Second, an adaptive extended state observer (AESO) is utilized to estimate the states of the EHF system and total disturbances, in which the observer gains are updated
... Show More