Preferred Language
Articles
/
cuYkv50BmraWrQ4dr1sC
High-density perovskite oxide ceramics with enhanced proton stopping power and gamma-ray shielding efficiency
...Show More Authors

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Fri Jun 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
Banking efficiency between concept and measurement methods
...Show More Authors

The research aims to review the concepts of banking efficiency and its relationship to performance, productivity and efficiency, as well as analyze the efficiency of the banking in micro-economic view.
In order to achieve the objectives of the research We have been employed graphic, Econometrics  and Mathematical methods to derive the different concepts of banking efficiency.

We showed that there are two main methods used to measure the bank efficiency, the first called Stochastic Frontier Analysis , this technique depends on the parametric methods, The other method is called Data Envelopment Analysis is based on mathematical programming methods

View Publication Preview PDF
Crossref
Publication Date
Wed Sep 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Mechanical Evaluation of Pure Titanium Dental Implants Coated with a Mixture of Nano Titanium Oxide and Nano Hydroxyapatite
...Show More Authors

Background: The type of dental implant surface is one of many factors that determine the success of implant restoration. This study aimed to study the effect of mixture of nano titanium oxide with nanohydroxyapatite coating of screw shaped CPTi dental implant on bond strength at bone implant interface by torque removal test related to two healing periods (2 and 6 weeks). Materials and methods: Dip coating process was performed to get an even coating layer on CPTi screws. X-ray diffraction (XRD) analysis and microscopical examination were performed on the coating surfaces of the CPTi. The tibia of 10 white New Zealand rabbits was chosen as implantation sites. The tibia of each rabbit received two screws, one was coated with mixture of nanoT

... Show More
View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Mon Apr 08 2024
Journal Name
Biomed Research International
Evaluation of High-Performance Polyether Ether Ketone Polymer Treated with Piranha Solution and Epigallocatechin-3-Gallate Coating
...Show More Authors

Background. Dental implantation has become a standard procedure with high success rates, relying on achieving osseointegration between the implant surface and surrounding bone tissue. Polyether ether ketone (PEEK) is a promising alternative to traditional dental implant materials like titanium, but its osseointegration capabilities are limited due to its hydrophobic nature and reduced surface roughness. Objective. The aim of the study is to increase the surface roughness and hydrophilicity of PEEK by treating the surface with piranha solution and then coating the surface with epigallocatechin-3-gallate (EGCG) by electrospraying technique. Materials and Methods. The study includes four groups intended to investigate the effect of pir

... Show More
View Publication
Scopus (6)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Annals Of Tropical Medicine And Public Health
Role of high sensitivity C - Reactive protein and some of heavy metals in patients with rheumatoid arthritis
...Show More Authors

View Publication
Scopus (7)
Crossref (4)
Scopus Crossref
Publication Date
Fri Dec 20 2019
Journal Name
Iet Circuits, Devices & Systems
Multi‐bit error control coding with limited correction for high‐performance and energy‐efficient network on chip
...Show More Authors

In the presence of deep submicron noise, providing reliable and energy‐efficient network on‐chip operation is becoming a challenging objective. In this study, the authors propose a hybrid automatic repeat request (HARQ)‐based coding scheme that simultaneously reduces the crosstalk induced bus delay and provides multi‐bit error protection while achieving high‐energy savings. This is achieved by calculating two‐dimensional parities and duplicating all the bits, which provide single error correction and six errors detection. The error correction reduces the performance degradation caused by retransmissions, which when combined with voltage swing reduction, due to its high error detection, high‐energy savings are achieved. The res

... Show More
View Publication
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Thu Nov 27 2025
Journal Name
Bulletin Of The Chemical Society Of Ethiopia
Impact of defect-containing graphene oxide nanosheets on the structural, electrical, and dielectric characteristics of graphene oxide
...Show More Authors

In this work, two graphene oxide (GO) samples were prepared using the Hummers method with graphite (g) and KMnO4 (g) ratios of 1:3 (GO3) and 1:6 (GO6). The effect of oxidation degree on the structural, electrical, and dielectric properties of the GO samples was investigated. The structures of the GO samples were studied using various techniques, including X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy, scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDXS). XRD analysis revealed an increase in the interlayer spacing and a decrease in the number of layers of the samples with increasing oxidant content. The two GO samples have giant permittivity values of ~105 in the low-frequency

... Show More
View Publication
Scopus Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Aip Conference Proceedings
Gamma irradiation effect on characterization of MoO3 nanostructures films
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Mar 31 2018
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Synthesis of Nano Crystalline Gamma Alumina from Waste Cans
...Show More Authors

In the present study waste aluminium cans were recycled and converted to produce alumina catalyst. These cans contain more than 98% aluminum oxide in their structure and were successfully synthesized to produce nano sized gamma alumina under mild conditions. A comprehensive study was carried out in order to examine the effect of several important parameters on maximum yield of alumina that can be produced. These parameters were reactants mole ratios (1.5, 1.5, 2, 3, 4 and 5), sodium hydroxide concentrations (10, 20, 30, 40, 50 and 55%) and weights of aluminum cans (2, 4, 6, 8 and 10 g). The compositions of alumina solution were determined by Atomic absorption spectroscopy (AAS); and maximum yield of alumina solution was 96.3% obtain

... Show More
View Publication Preview PDF
Publication Date
Thu Mar 09 2017
Journal Name
Sensors
A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging
...Show More Authors

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detec

... Show More
View Publication
Scopus (24)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Feb 11 2021
Journal Name
Physics In Medicine & Biology
Stereoscopic portable hybrid gamma imaging for source depth estimation
...Show More Authors
Abstract<p>Advances in gamma imaging technology mean that is now technologically feasible to conduct stereoscopic gamma imaging in a hand-held unit. This paper derives an analytical model for stereoscopic pinhole imaging which can be used to predict performance for a wide range of camera configurations. Investigation of this concept through Monte Carlo and benchtop studies, for an example configuration, shows camera-source distance measurements with a mean deviation between calculated and actual distances of <5 mm for imaging distances of 50–250 mm. By combining this technique with stereoscopic optical imaging, we are then able to calculate the depth of a radioisotope source beneath a surfa</p> ... Show More
View Publication
Scopus (8)
Crossref (8)
Scopus Clarivate Crossref