Preferred Language
Articles
/
chcGOI8BVTCNdQwCCGOj
Energy-aware evolutionary routing protocol for dynamic clustering of wireless sensor networks
...Show More Authors

Scopus Clarivate Crossref
Publication Date
Thu Aug 21 2025
Journal Name
Computers
A Comprehensive Review of Sensor Technologies in IoT: Technical Aspects, Challenges, and Future Directions
...Show More Authors

The rapid advancements in wireless technology and digital electronics have led to the widespread adoption of compact, intelligent devices in various aspects of daily life. These advanced systems possess the capability to sense environmental changes, process data, and communicate seamlessly within interconnected networks. Typically, such devices integrate low-power radio transmitters and multiple smart sensors, hence enabling efficient functionality across wide ranges of applications. Alongside these technological developments, the concept of the IoT has emerged as a transformative paradigm, facilitating the interconnection of uniquely identifiable devices through internet-based networks. This paper aims to provide a comprehensive ex

... Show More
View Publication
Crossref (11)
Crossref
Publication Date
Tue Jan 18 2022
Journal Name
Photonic Sensors
Arsenic Detection Using Surface Plasmon Resonance Sensor With Hydrous Ferric Oxide Layer
...Show More Authors
Abstract<p>The lethality of inorganic arsenic (As) and the threat it poses have made the development of efficient As detection systems a vital necessity. This research work demonstrates a sensing layer made of hydrous ferric oxide (Fe<sub>2</sub>H<sub>2</sub>O<sub>4</sub>) to detect As(III) and As(V) ions in a surface plasmon resonance system. The sensor conceptualizes on the strength of Fe<sub>2</sub>H<sub>2</sub>O<sub>4</sub> to absorb As ions and the interaction of plasmon resonance towards the changes occurring on the sensing layer. Detection sensitivity values for As(III) and As(V) were 1.083 °·ppb<sup>−1</sup> and 0.922 °·ppb<jats></jats></p> ... Show More
View Publication
Scopus (11)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Refractive index sensor based on a solid-core photonic crystal fiber interferometer
...Show More Authors

Photonic crystal fiber interferometers are widely used for sensing applications. In this work, solid core-Photonic crystal fiber based on Mach-Zehnder modal interferometer for sensing refractive index was presented. The general structure of sensor applied by splicing short lengths of PCF in both sides with conventional single mode fiber (SMF-28). To apply modal interferometer theory; collapsing technique based on fusion splicing used to excite higher order modes (LP01 and LP11). Laser diode (1550 nm) has been used as a pump light source. Where a high sensitive optical spectrum analyzer (OSA) was used to monitor and record the transmitted. The experimental work shows that the interference spectrum of Photonic crystal fiber interferometer

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Sep 01 2021
Journal Name
Iraqi Journal Of Physics
Surface Plasmon Plastic Optical Fiber Resonance with Multi-Layer as Chemical Sensor
...Show More Authors

A chemical optical fiber sensor based on surface plasmon resonance (SPR) was developed and implemented using multimode plastic optical fiber. The sensor is used to detect and measure the refractive index and concentration of various chemical materials (Urea, Ammonia, Formaldehyde and Sulfuric acid) as well as to evaluate the performance parameters such as sensitivity, signal to noise ratio, resolution and figure of merit. It  was noticed that the value of the sensitivity of the optical fiber-based SPR sensor, with 60nm and 10 mm long, Aluminum(Al) and Gold (Au) metals film exposed sensing region, was 4.4 μm, while the SNR was 0.20, figure of merit was 20 and resolution 0.00045. In this work a multimode

... Show More
View Publication Preview PDF
Crossref (10)
Crossref
Publication Date
Sat Sep 01 2018
Journal Name
Iraqi Journal Of Science
Polymer optical fiber sensor side-pumped with polymer clad doped lasing compounds
...Show More Authors

Preview PDF
Scopus (4)
Scopus Crossref
Publication Date
Sun Oct 01 2023
Journal Name
Optical Fiber Technology
A taper-in-etch based hybrid fiber Mach-Zehnder interferometer hydrogen sensor
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Sat Apr 01 2023
Journal Name
Baghdad Science Journal
Photonic Crystal Fiber Pollution Sensor Based on the Surface Plasmon Resonance Technology
...Show More Authors

Photonic Crystal Fiber (PCF) based on the Surface Plasmon Resonance (SPR) effect has been proposed to detect polluted water samples. The sensing characteristics are illustrated using the finite element method. The right hole of the right side of PCF core has been coated with chemically stable gold material to achieve the practical sensing approach. The performance parameter of the proposed sensor is investigated in terms of wavelength sensitivity, amplitude sensitivity, sensor resolution, and linearity of the resonant wavelength with the variation of refractive index of analyte. In the sensing range of 1.33 to 1.3624, maximum sensitivities of 1360.2 nm ∕ RIU and 184 RIU−1 are achieved with the high sensor resolutions of 7

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (12)
Scopus Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Step-up protocol gonadotrophin versus laparoscopic ovarian drilling in clomiphene citrate resistant PCOS infertile women in two Iraqi hospitals
...Show More Authors

Background: Polycystic ovarian syndrome is a common endocrine disorder affecting 6-10% of women of reproductive age and the most common cause of anovulatory infertility. Objective: The aim of the study was to compare the effectiveness, side effects and outcomes of step-up gonadotrophin protocol versus laparoscopic ovarian diathermy (LOD) in infertile patients with clomiphene citrate resistant polycystic ovary syndrome. Methods:  The sample included women who attended our infertility clinic at Al-Elwiya Maternity Teaching Hospital and Kamal Al-Samarraee for Infertility and IVF Hospital in Baghdad/ Iraq from November 2013 to November 2014.    Eighty cases of infertile women with polycystic ovarian syndrome who failed t

... Show More
Crossref (1)
Crossref
Publication Date
Thu Sep 12 2019
Journal Name
Al-kindy College Medical Journal
Step-up protocol gonadotrophin versus laparoscopic ovarian drilling in clomiphene citrate resistant PCOS infertile women in two Iraqi hospitals
...Show More Authors

Background: Polycystic ovarian syndrome is a common endocrine disorder affecting 6-10% of women of reproductive age and the most common cause of anovulatory infertility.

Objective: The aim of the study was to compare the effectiveness, side effects and outcomes of step-up gonadotrophin protocol versus laparoscopic ovarian diathermy (LOD) in infertile patients with clomiphene citrate resistant polycystic ovary syndrome.

Methods:  The sample included women who attended our infertility clinic at Al-Elwiya Maternity Teaching Hospital and Kamal Al-Samarraee for Infertility and IVF Hospital in Baghdad/ Iraq from November 2013 to November 2014.    Eighty case

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Wed Aug 28 2019
Journal Name
Journal Of Engineering
Treatment of Simulated Carwash Wastewater by Electrocoagulation with Sonic Energy
...Show More Authors

Oily carwash wastewater is a high organic and chemical wastewater. This paper targeted to investigate a treatment to decrease the water consumption and contaminants in car-washing stations. Electrocoagulation combined with ultrasonic energy (Sono-Electrocoagulation) was suggested so that the carwash wastewater is treated to be reused. The effect of both the voltage and time of treatment on the removal of COD, turbidity, conductivity, and total dissolved solids (TDS) were studied at constant initial pH 7 and electrode distance 2 cm. The results showed the best results of removal COD, turbidity, TDS, and reduce electrical conductivity is when the voltage was 30 V and a treatment time of 90 minutes.

  <

... Show More
View Publication Preview PDF
Crossref (3)
Crossref