Preferred Language
Articles
/
cRZLYocBVTCNdQwC7EkW
Assessment of consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite
...Show More Authors

Background: Glass ionomers have good biocompatibility and the ability to adhere to both enamel and dentin. However, they have certain demerits, mainly low tensile and compressive strengths. Therefore, this study was done to assess consistency and compressive strength of glass ionomer reinforced by different amount of hydroxyapatite. Materials and Methods: In this study hydroxyapatite materials were added to glass ionomer cement at different ratios, 10%, 15%, 20%, 25% and 30% (by weight). The standard consistency test described in America dental association (ADA) specification No. 8 was used, so that all new base materials could be conveniently mixed and the results would be of comparable value and the compressive strength test described by British standard specification for zinc polycarboxylate cement was used in this study. Results: Different consistencies of materials produced a disc of varying sizes. The amount of the powder (in milligram) was mixed with 0.5 ml of liquid to produce a consistency giving a disc of 3 cm±1mm in diameter were 500 mg for glass monomer cement, 450 mg for glass ionomer cement reinforced by 10%, 5% and 30% of hydroxyapatite and 350 mg for glass ionomer cement reinforced by 20% and 25% of hydroxapatite. The results showed that the glass ionomer cement reinforced by hydroxyapatite has higher compressive strength than conventional glass ionomer. Conclusion: The addition of hydroxyapatite to conventional glass ionomer requires less powder to liquid ratio. Addition of hydroxyapatite to glass ionomer cement increased its compressive strength.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed May 29 2019
Journal Name
Iraqi Journal Of Physics
Impact strength behaviour of PMMA denture base through addition of different nanoparticles after immersion in some nutrition liquids
...Show More Authors

Poly methyl methacrylate PMMA polymer could be considered the main material that used mostly in the recent years in denture base fabrication. It commonly known by it is poor strength properties such as low impact strength. The aim of the present research was to enhance the performance of PMMA denture base through the addition of two kind of nanoparticles (nano particles that selected from artificial and natural sources). Nano -particles from both Al2O3 and crushed peanut Peel were used for comparing purposes.Various weight fraction used in this study for both kinds of the additive (1%, 2% and 3%). Moreover, in this work a study and evaluation in impact strength (I.S.) value were done before and after immersion. The new prepared nanocompo

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Sat Jul 18 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Evaluation of frictional forces generated by different brackets and orthodontic wires
...Show More Authors

Background: Sliding mechanics is widely used during orthodontic treatment. One of the disadvantages of this mechanics is the friction generated at the bracket/archwire interface, which may reduce the amount of desired orthodontic movement obtained. The aim of the present in vitro study was to evaluate and compare the static frictional forces produced by two passive self-ligating brackets stainless-steel and hybrid and two conventional brackets stainless-steel and monocrystal ligated with stainless-steel ligature wire at two degrees of torque(zero and twenty) under dry condition. Materials and method: One hundred and sixty brackets were used in this study divided into four groups each group consisted of forty brackets these are: Two self-li

... Show More
View Publication Preview PDF
Publication Date
Wed Dec 14 2016
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of Enamel Surface after Debonding of Different Types of Esthetic Brackets (An In Vitro Study)
...Show More Authors

Background: Debonding orthodontic brackets and removal of residual bonding material from the enamel surface include critical steps that may cause enamel damage. The aim of the present study was to evaluate and compare the site of bond failure and enamel surface damage after debonding of three types of esthetic brackets (composite, ceramic, sapphire) bonded with light cure composite and resin-modified glass ionomer adhesive. Materials and methods: Seventy two maxillary premolars teeth were divided into three groups each group consisted of 24 teeth according to the type of brackets. Each group was subdivided into two subgroups (12 teeth for each) according to the bonding material that was used. After 7 days of bonding procedure, the brackets

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sat Sep 01 2007
Journal Name
Al-khwarizmi Engineering Journal
Study of Mechanical Characteristics for Polymer Composite Reinforced by Particles of (Al2O3) or (Al)
...Show More Authors

A particulate polymer composite material was prepared by reinforcing with the Aluminum Oxide (Al2O3) or Aluminum (Al) metallic particles with a particle size of (30) µm to an unsaturated Polyester Resin with a weight fraction of (5%, 10%, 15%, 20%).

Tensile test results showed the maximum value of elastic modulus reached (2400MPa.)  in the case of reinforcing with (Al) particles with weight fraction (20%) and (1500 MPa.)  in the case of reinforcing with (Al2O3) particles of the same weight fraction.

  When the impact and the flexural strength tests were done, the results showed that flexural strength (F.S), maximum shear stress (τmax), impact strength

... Show More
View Publication Preview PDF
Publication Date
Tue Jan 01 2019
Journal Name
Plant Archives
Assessment of organic carbon content in different topographic from northern Iraq using remote sensing technique and GIS
...Show More Authors

Scopus (2)
Scopus
Publication Date
Sun Jan 01 2023
Journal Name
Sport Tk - Revista Euro Americana De Ciencias Del Deporte
Analysis of the amount of lost fluids, some blood components and mineral salts in volleyball under hot weather conditions
...Show More Authors

Scopus (7)
Scopus
Publication Date
Tue Jul 11 2023
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Analysis of the amount of lost fluids, some blood components and mineral salts in volleyball under hot weather conditions
...Show More Authors

The research objective was to study the amount of lost fluids, some blood components and mineral salts in volleyball players under hot weather conditions. The sample of the present study was composed of 12 volleyball players of Al-Sinaa Club (Baghdad, Iraq) in the 2022/2023 season. The variables analyzed in this study were: Heart rate before and after exercise, internal and external body temperature before and after exertion, potassium ion, sodium ion, calcium ion, and the amount of fluid lost (the player's weight) before and after the exercise. The tests were conducted at a temperature between 42-47 degrees Celsius. The maximum anaerobic exercise was performed with volleyball. The results showed that to play volleybal

... Show More
View Publication
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Tue Jul 11 2023
Journal Name
Sport Tk-revista Euroamericana De Ciencias Del Deporte
Analysis of the amount of lost fluids, some blood components and mineral salts in volleyball under hot weather conditions
...Show More Authors

The research objective was to study the amount of lost fluids, some blood components and mineral salts in volleyball players under hot weather conditions. The sample of the present study was composed of 12 volleyball players of Al-Sinaa Club (Baghdad, Iraq) in the 2022/2023 season. The variables analyzed in this study were: Heart rate before and after exercise, internal and external body temperature before and after exertion, potassium ion, sodium ion, calcium ion, and the amount of fluid lost (the player's weight) before and after the exercise. The tests were conducted at a temperature between 42-47 degrees Celsius. The maximum anaerobic exercise was performed with volleyball. The results showed that to play volleybal

... Show More
View Publication
Scopus (7)
Scopus Clarivate Crossref
Publication Date
Sun Jun 12 2022
Journal Name
Journal Of Positive School Psychology
international Accounting Standards for Presentation and Disclosure and their Consistency with Islamic Accounting Standards in Ialamic Banks
...Show More Authors

The aim of the research is to identify the international accounting standards and accounting standards for Islamic banks, and to analyze the most important problems in the application of Islamic accounting standards, as well as to analyze some of the principles and methods used in the application of accounting standards in Islamic banks. The research was built on three hypotheses, the first being (there is a tangible impact on the application of international accounting standards for banks’ management of liquidity, achieving profits, maintaining property rights and fulfilling their obligations), and the second (the bank facing obstacles using Islamic accounting standards, as it is expected that when using Islamic accounting standar

... Show More
View Publication
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Comparative Assessment of the Effect of Gutta-Fusion Obturation on the Push Out Bond Strength of Three Types of Sealers
...Show More Authors

Background: The bond strength of the root canal sealers to dentin is very important property for maintaining the integrity and the seal of root canal filling. The aim of this study was to evaluate and compare the push-out bond strength of root filled with total fill Bioceramic, AH Plus and Gutta-flow®2 sealers using GuttaFusion®obturation system versus single cone obturation technique. Materials and method: sixty of mandibular premolars teeth with straight roots were used in this study, these roots were instrumented using Reciproc system, instrumentation were done with copious irrigation of 3 mL 5.25% sodium hypochlorite solution (NaOCl) during all the steps of preparation, and smear layer will be removed with 1 ml of 17% EDTA kept in

... Show More
View Publication Preview PDF
Crossref (2)
Crossref