Abstract Background: Colorectal cancer (CRC) is a leading cause of cancer mortality worldwide. Identifying novel biomarkers is critical for improving diagnosis, prognosis, and treatment strategies. This study investigates the serum levels of kisspeptin-1 (KISS1), its receptor (KISS1R), growth differentiation factor 15 (GDF15), and carcinoembryonic antigen (CEA) in Iraqi CRC patients. Objectives: Explore associations between serum levels of Kiss1, Kiss1R, GDF, and CEA and disease progression in Iraqi patients with CRC. Methods: A case-control study was conducted, including 72 CRC patients and 36 healthy controls. Patients were stratified into non-metastatic and metastatic groups. Serum biomarker levels were measured using enzyme-linked immunosorbent assay (ELISA). Statistical analyses evaluated biomarker correlations, diagnostic accuracy, and associations with CRC stages. Results: Significant elevations of KISS1, KISS1R, GDF15, and CEA levels were observed in CRC patients compared to controls, with metastatic cases showing the highest levels. KISS1 and GDF15 demonstrated strong correlations and were particularly associated with metastatic disease. Receiver operating characteristic (ROC) analysis revealed high diagnostic accuracy for these biomarkers in distinguishing CRC stages. Conclusions: KISS1 and GDF15 are promising biomarkers for CRC progression and metastasis. Their coordinated elevation in metastatic cases suggests potential roles in disease monitoring and therapeutic targeting. Further studies are needed to confirm these findings and explore their clinical applications.
The study deals with the issue of multi-choice linear mathematical programming. The right side of the constraints will be multi-choice. However, the issue of multi-purpose mathematical programming can not be solved directly through linear or nonlinear techniques. The idea is to transform this matter into a normal linear problem and solve it In this research, a simple technique is introduced that enables us to deal with this issue as regular linear programming. The idea is to introduce a number of binary variables And its use to create a linear combination gives one parameter was used multiple. As well as the options of linear programming model to maximize profits to the General Company for Plastic Industries product irrigation sy
... Show More
Codes of red, green, and blue data (RGB) extracted from a lab-fabricated colorimeter device were used to build a proposed classifier with the objective of classifying colors of objects based on defined categories of fundamental colors. Primary, secondary, and tertiary colors namely red, green, orange, yellow, pink, purple, blue, brown, grey, white, and black, were employed in machine learning (ML) by applying an artificial neural network (ANN) algorithm using Python. The classifier, which was based on the ANN algorithm, required a definition of the mentioned eleven colors in the form of RGB codes in order to acquire the capability of classification. The software's capacity to forecast the color of the code that belongs to an ob
... Show MoreThis study was conducted to test the effectiveness of Agaricus bisporus inoculums (spawn) in the ratio of (0.25, 0.5 and 1%) v/v to control Pythium aphanidermatum fungus the causal agent of damping- off disease of cucumber plant. results showed the ability of A. bisporus fungus to protect the seedlings from incidence by P. aphanidermatum . all treatments of edible fungus inoculums were significantly different from pathogen treatment after 15 day of planting and there was no significant difference found from control treatment (without pathogen) . the successful of A. bisporus was continued to protect the seedlings after 30 and 45 day after planting. The numbers of seedlings were (8, 7.25 & 7.25) respectively compared to 5.5 seedlings in con
... Show MoreIs in this research review of the way minimum absolute deviations values based on linear programming method to estimate the parameters of simple linear regression model and give an overview of this model. We were modeling method deviations of the absolute values proposed using a scale of dispersion and composition of a simple linear regression model based on the proposed measure. Object of the work is to find the capabilities of not affected by abnormal values by using numerical method and at the lowest possible recurrence.
The Neutron Fermi Age, t, and the neutron slowing down density, q (r, t) , have been measured for some materials such as Graphite and Iron by using gamma spectrometry system UCS-30 with NaI (Tl) detector. This technique was applied for Graphite and Iron materials by using Indium foils covered by Cadmium and the measurements done at the Indium resonance of 1.46 eV. These materials are exposed to a plane 241Am/Be neutron source with recent activity 38 mCi. The measurements of the Fermi Age were found to be t = 297 ± 21 cm2 for Graphite, t = 400 ± 28 cm2 for Iron. Neutron slowing down density was also calculated depending on the recent experimental t value and distance.
A new class of higher derivatives for harmonic univalent functions defined by a generalized fractional integral operator inside an open unit disk E is the aim of this paper.
The current study included the isolation, purification and cultivation of blue-green alga Oscillatoria pseudogeminata G.Schmidle from soil using the BG-11liquid culture medium for 60 days of cultivation. The growth constant (k) and generation time (G) were measured which (K=0.144) and (G=2.09 days).
Microcystins were purified and determined qualitatively and quantitatively from this alga by using the technique of enzyme linked immunosorbent assay (Elisa Kits). The alga showed the ability to produce microcystins in concentration reached 1.47 µg/L for each 50 mg DW. Tomato plants (Lycopersicon esculentum) aged two months were irrigated with three concentrations of purified microcystins 0.5 , 3.0 and 6.0
... Show MoreA newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma
... Show More