Preferred Language
Articles
/
cBhee5UBVTCNdQwC0y55
The Effect of Pepsi Cola Beverage on Surface Roughness of Two Composite Resins (In Vitro study)
...Show More Authors

An acidic environment causes surface changes of resin composites. Filler particlesize and filler distribution also have a direct effect on these surface changes. This invitro study evaluated the influence of Pepsi Cola drink on the surface roughness ofComposan LCM and Composan Ceram over time. Sixteen disc shaped specimens(10mm diameter, 2mm thickness) of each resin composite were fabricated, therebyforming two groups (n= 8). Surface roughness (Ra) was analyzed after 24 hrs beforeexposure to beverage. The specimens were submitted to a five minutes immersion inPepsi Cola three times daily interrupted by immersion in deionized distilled water (37C˚). Surface roughness measurements were done at 10, 30, and 60 days intervals. Datawere submitted to paired t-test. There was a statistically highly significant (p <0.001)increase in surface roughness values of the tested composites after 30 days and 60days immersion in Cola drink. Composan LCM exhibited a significantly (p <0.05)higher surface roughness values than Composan Ceram.The surface roughness of the composite materials are significantly affected byexposure to acidic drink over time, highly filled micro hybrid composites with smallfiller particle size are significantly more resistant to acid erosion.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Jul 01 2025
Journal Name
Minerva Dental And Oral Science
Evaluation of the microleakage of new bioactive restorative materials: a comparative in-vitro study
...Show More Authors

View Publication
Scopus Clarivate Crossref
Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Photodynamic Therapy for Leiomyosarcoma: In vitro study
...Show More Authors

Leiomyosarcoma (smooth muscle tumor) is a rare type of a malignant neoplasm of smooth
muscle. It is a resistant cancer, generally not very responsive to chemotherapy, radiationand surgery.The
aim of this study was to evaluate photodynamic therapy (PDT) as a possible basis for treatment using
(650 nm)diode laser with methyleneblue (MB) as a photosensitizer on leiomyosarcoma (LMS)cell line
(L20B) in vitro. The cytotoxic effects of 650nm diode laser 0.052 W/cm2 (power density) at different
exposure time (10, 20, and 30 min) with methylene blue at different concentrations (0.01% ,0.1 % ,1%)
was investigated on LMS cell line (L20 B). The cytotoxic effect of laser was increased with increasing
irradiation time for a certai

... Show More
View Publication Preview PDF
Publication Date
Sun Mar 07 2010
Journal Name
Baghdad Science Journal
Study of the Singlet and the Triplet States of Two ElectronSystems in the First Excited State
...Show More Authors

A study of the singlet and triplet states of two electron systems in the first excited state was performed using a simple quantum mechanical model, which assigns the 1s,and 2s orbital with two different variational parameters. Our results agree with a high level calculation used by Snow and Bills.

View Publication Preview PDF
Crossref
Publication Date
Wed Apr 05 2017
Journal Name
International Journal Of Science And Research
Antibacterial Effects of Pomegranate Extract (Ellagic Acid) on Some Clinically Isolated Periodontal Pathogens in Vitro Study
...Show More Authors

Publication Date
Wed Sep 15 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of contact time between alginate impression material and type III dental stone on the surface properties of stone casts
...Show More Authors

Background: Alginate impression material is the irreversible hydrocolloid material that is widely used in dentistry. The contact time between alginate and gypsum cast could have a detrimental effect on the properties of the gypsum cast. The objective of this study is to evaluate the impact of various contact time intervals of Alginate impressions & type III dental stone on surface properties of stone cast. Materials and Methods: Time intervals tested were 1hour, 6 hours and 9 hours. Surface properties of stone cast evaluated were surface detail reproduction, hardness and roughness. Surface detail reproduction was determined using cylindrical brass test block in accordance with ISO 1563. Surface roughness was measured by profilometer

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Aug 16 2023
Journal Name
Journal Of Humanities And Social Sciences Research
The impact of the use of hydromassage rehabilitation exercises on the recovery of certain motor potentials of knee roughness sufferers
...Show More Authors

The research included the introduction to the research and its importance as knee joint is an important joint in the human body that is prone to injury. One such injury is knee roughness injury that occurs as a result of the stress of the knee joint and age. The importance of examining the need for the use of rehabilitation exercises, especially in the watercourse system, is highlighted by the fact that the aquatic environment is one of the most important factors helping to alleviate pain and rehabilitate the knee joint and thereby improve the mobility of those with knee roughness. The problem of research is that rehabilitation exercises have been developed in the watercourse system on the basis of scientific bases with a repetitive and sys

... Show More
View Publication Preview PDF
Publication Date
Wed Mar 15 2023
Journal Name
Journal Of Baghdad College Of Dentistry
Crystallization firing effect on the marginal discrepancy of the IPS. emax CAD crowns using two different CAD/CAM systems
...Show More Authors

Background: Marginal adaptation is critical for long – term success of crown and bridge restoration. Computer aided design / computer aided manufacture (CAD/ CAM) system is gaining more importance in the fabrication of dental restoration. Objective: The aim of this study is to evaluate the effect of crystallization firing on the vertical marginal gap of IPS. emax CAD crowns which fabricated with two different CAD/CAM systems .Materials and Methods: Twenty IPS e.max CAD crowns were fabricated. We had two major groups (A, B) (10 crowns for each group) according to the CAD/CAM system being used: Group A: fabricated with Imes - Icore CAD/CAM system; Group B: fabricated with In Lab Sirona CAD/CAM system. Each group was subdivided into two s

... Show More
View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Thu Oct 03 2024
Journal Name
Dentistry 3000
Antimicrobial Efficiency of Hypochlorous Acid Incorporation and its Effect on Surface Properties of Irreversible Hydrocolloid Materials
...Show More Authors

Objective: Conventional approaches for disinfection, including spraying and immersion, resulted in only surface disinfection of impressions. As a result, self-disinfecting impression materials incorporated with antimicrobial compounds require more extensive studies. The incorporation of a disinfectant into irreversible hydrocolloid impression materials could eliminate the need for the disinfection step by conventional approaches, including spraying and immersion which only result in surface disinfection of impressions. The study was aimed to investigate the effect of incorporation of hypochlorous acid in irreversible hydrocolloid materials on antimicrobial efficiency, detail reproduction, and dimensional stability. Materials and

... Show More
View Publication
Scopus Crossref
Publication Date
Sun Jan 01 2023
Journal Name
Dental Hypotheses
Assessment of the Impact of Adhesive and Wires Types on the Tensile Bond Strength of Fixed Lingual Retainers Used in Orthodontics: An In Vitro Study
...Show More Authors

Introduction: We aimed to assess the impact of adhesive and wires types on the tensile bond strength of fixed lingual retainers. Methods: A total of 160 intact bovine teeth were collected, cleaned, stored in 25% sodium hypochlorite, and randomly assigned to two groups based on the adhesive type: a two-step adhesive and a one-step adhesive. Each group was further divided into four subgroups based on the type of lingual retainer wire, which included (A) 8-strand braided stainless steel wire, (B) three-strand titanium retainer wire, (C) stainless steel chain, and (D) fiber-reinforced retainer. A tensile bond strength test was conducted using a universal testing machine at a controlled speed of 10 mm/min. Result: The 8-strand braided stainles

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Mon Mar 13 2017
Journal Name
Journal Of Baghdad College Of Dentistry
The Effects of Enamel Protective Agents on Shear Bond Strength After Rebonding of Stainless Steel Orthodontic Bracket (An in Vitro Study)
...Show More Authors

ABSTRACT Background: Bracket rebonding is a common problem in orthodontics which may result in many drawbacks. The aims of this study were to evaluate the effects of application of two enamel protective agents “Icon” and “ProSeal” on shear bond strength before and after rebonding of stainless steel orthodontic brackets using conventional orthodontic adhesive and to assess the site of bond failure. Materials and methods: Fifty sound extracted human upper first premolar teeth were selected and randomly divided into two equal groups; the first time bonding and the rebonding groups (n=30). Each group was subdivided into control, Icon and ProSeal subgroups. The enamel protective agents were applied after etching (precondi

... Show More
View Publication Preview PDF
Crossref (5)
Crossref