An enzyme linked immunosorbent assay (ELISA) for the detection and quantitation of human immunoglobulin G (IgG) antibodies against vero- cytotoxine (VT) producing Escherichia coli serogroup O157:H7 was produced. E. coli O157: H7 lipopolysaccharide was extracted from locally isolated strains by using hot phenol- water method, followed by partial purification using gel filtration chromatography by sepharose- 4B. The purity of the lipopolysaccharide was checked by measuring the protein and nucleic acid content and then used as antigen. Four isolates of vero- cytotoxin producing E. coli serogroup O157:H7 was obtained by culturing 350 stool samples from children suffering from bloody diarrhea. These isolates were identified on bacteriological, serological and biochemical basis. Toxin production was confirmed on laboratory animals as well as by cytopathic effect on tissue culture. The possibility of using E. coli O157:H7 lipopolysaccharide in an enzyme- linked immunosorbent assay for the routine diagnostic testing of serum from patients for evidence of O157:H7 infection is discussed.
In Automatic Speech Recognition (ASR) the non-linear data projection provided by a one hidden layer Multilayer Perceptron (MLP), trained to recognize phonemes, and has previous experiments to provide feature enhancement substantially increased ASR performance, especially in noise. Previous attempts to apply an analogous approach to speaker identification have not succeeded in improving performance, except by combining MLP processed features with other features. We present test results for the TIMIT database which show that the advantage of MLP preprocessing for open set speaker identification increases with the number of speakers used to train the MLP and that improved identification is obtained as this number increases beyond sixty.
... Show Morein this paper we adopted ways for detecting edges locally classical prewitt operators and modification it are adopted to perform the edge detection and comparing then with sobel opreators the study shows that using a prewitt opreators
A LiF (TLD-700) PTFED disc has adiameter of (13mm) and thickness of (0.4mm) for study the response and sensetivity of this material for gamma and beta rays by using (TOLEDO) system from pitman company. In order to calibrate the system and studying the calibration factor. Discs were irradiated for Gamma and Beta rays and comparing with the theoretical doses. The exposure range is between 15×10-2 mGy to 1000×10-2 mGy. These doses are within the range of normal radiation field for workers.
Data hiding is the process of encoding extra information in an image by making small modification to its pixels. To be practical, the hidden data must be perceptually invisible yet robust to common signal processing operations. This paper introduces a scheme for hiding a signature image that could be as much as 25% of the host image data and hence could be used both in digital watermarking as well as image/data hiding. The proposed algorithm uses orthogonal discrete wavelet transforms with two zero moments and with improved time localization called discrete slantlet transform for both host and signature image. A scaling factor ? in frequency domain control the quality of the watermarked images. Experimental results of signature image
... Show MoreThis paper presents a study of wavelet self-organizing maps (WSOM) for face recognition. The WSOM is a feed forward network that estimates optimized wavelet based for the discrete wavelet transform (DWT) on the basis of the distribution of the input data, where wavelet basis transforms are used as activation function.