The primary toxin class discovered in freshwater pufferfish is a category of neurotoxins called PSTs (Paralytic shellfish toxins) and pufferfish toxin has been observed to have biological, biochemical, and cytotoxic effects on cancer cell lines. Therefore, it is crucial to determine the cytotoxic activity, toxins present in the ovary of T. leiurus, and interaction between ligand (toxin compound) and receptors test. This study used the MTT method in the T47D cell lines, liquid chromatograph-tandem mass spectrometry (LC-MS/MS), and analysis of the molecular interaction using molecular docking. The ovary of T. leiurus had cytotoxicity on the T47D cell, having an IC50 value of 229.535 μg/ml, and generated a chromatogram with a retention duration of 1.25 min that was similar to the Decarbamoylneosaxitoxin (dcNEO) standard solution. In molecular interactions between the dcNEO ligand to receptors, the lowest ΔG value was -9.29 kcal/mol at the Nav 1.7 receptor, and the lowest KI value was 1.23 µM at the Mcl-1 receptor. These findings indicate that the ovary of T. leiurus is cytotoxic to the T47D cell line and contains dcNEO toxin. It is more stable for the dcNEO ligand to engage with the Nav 1.7 receptor than with other receptors, and it inhibits the Mcl-1 receptor more potently than with other receptors. These findings indicate that the ovary of T. leiurus may be chemotherapy for the prevention of cancer strategy.
Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.
... Show MoreExposure assays to magnetized water have so far revealed striking results. The present study was conducted to determine the effects of magnetized water treatment with in different intensities 500 , 1000 and 1500 Gauss on some biological aspects for species of freshwater Gastropod Lymnaea lagotis (Schrank, 1803) which important species in faun of aquatic habitats of Iraq. This species are considered a component of the food chain. The obtained results compared with these species which lived in the river(control). Result of these experiments showed increased significance the shell size (shell high, shell aperture length, shell aperture width and shell width) for L. lagotis with increased intensity magnetized water such as treated water with 1
... Show MoreAbstract: Background: High percentage of diabetes patients complain from post extraction hemorrhage. Many types of hemostatic materials are used to stop bleeding after teeth extraction: diode lasers are good hemostatic agents owing to their highly absorption by hemoglobin therefore they are used in soft tissue procedures with relatively no effects on dental hard tissues due to their poorly absorption by water and hydroxyapatite. Objectives: The aim of this study is to evaluate the efficiency of diode laser to assist the clot formation after tooth extraction for type II diabetes patients with minimum temperature elevation to prevent periodontal destruction. Materials and methods: From 12 type II diabetes patients (7 males and 5 females wi
... Show MoreThe Asymmetrical Castellated concavely – curved soffit Steel Beams with RPC and Lacing Reinforcement improves compactness and local buckling (web and flange local buckling), vertical shear strength at gross section (web crippling and web yielding at the fillet), and net section ( net vertical shear strength proportioned between the top and bottom tees relative to their areas (Yielding)), horizontal shear strength in web post (Yielding), web post-buckling strength, overall beam flexure strength, tee Vierendeel bending moment and lateral-torsional buckling, as a result of steel section encasement. This study presents two concentrated loads test results for seven specimens Asymmetrical Castellated concavely – curved soffit Steel Be
... Show Moret-Self-Compacting Concrete (SCC) reduces environmental noise and has more workability. This research presents an investigation of the behavior of SCC under mechanical loading (impact loading). Two types of cement have been used to produce SCC mixtures, Ordinary Portland Cement (OPC) and Portland Limestone Cement (PLC), which reduces the emission of carbon dioxide during the manufacturing process. The mixes were reinforced with Carbon Fiber Reinforced Polymer (CFRP) which is usually used to improve the seismic performance of masonry walls, to replace lost steel reinforcements, or to increase column strength and ductility. Workability tests were carried out for fresh SCC. Prepared concrete slabs of 500×500×50mm were tested for lo
... Show More