Preferred Language
Articles
/
bsj-8427
Existence of Fixed Points for Expansive Mappings in Complete Strong Altering JS-metric space
...Show More Authors

The paper aims at initiating and exploring the concept of extended metric known as the Strong Altering JS-metric, a stronger version of the Altering JS-metric. The interrelation of Strong Altering JS-metric with the b-metric and dislocated metric has been analyzed and some examples have been provided. Certain theorems on fixed points for expansive self-mappings in the setting of complete Strong Altering JS-metric space have also been discussed.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Mon Mar 27 2023
Journal Name
8th Engineering And 2nd International Conference For College Of Engineering – University Of Baghdad: Coec8-2021 Proceedings
Experimental study of natural convection heat transfer on an enclosure partially filled porous medium heated from below by constant heat flux
...Show More Authors

This study reports on natural convection heat transfer in a square enclosure of length (L=20 cm) with a saturated porous medium (solid glass beads) having same fluid (air) at lower horizontal layer and free air fill in the rest of the cavity's space. The experimental work has been performed under the effects of heating from bottom by constant heat flux q=150,300,450,600 W/m2 for four porous layers thickness Hp (2.5,5,7.5,1) cm and three heaters length δ(20,14,7) cm. The top enclosure wall was good insulated and the two side walls were symmetrically cooled at constant temperature. Four layers of porous media with small porosity, Rayleigh number range (60.354 - 241.41) and (Da) 3.025x10-8 has been investigated. The obtained data of temperatu

... Show More
View Publication
Scopus (6)
Crossref (5)
Scopus Crossref
Publication Date
Mon Nov 08 2021
Journal Name
Physica Scripta
Adsorption of the eosin yellow dye by nickel oxide nanoparticles catalyzes via oxalate co-precipitation method: isotherm, kinetic and thermodynamic studies
...Show More Authors

View Publication
Scopus (12)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
The Calculation and Analysis of the Total Electron Content Over Different Latitudes and Seasons Using the Numerical Trapezoidal and Simpson Methods
...Show More Authors

It has been shown in ionospheric research that calculation of the total electron content (TEC) is an important factor in global navigation system. In this study, TEC calculation was performed over Baghdad city, Iraq, using a combination of two numerical methods called composite Simpson and composite Trapezoidal methods. TEC was calculated using the line integral of the electron density derived from the International reference ionosphere IRI2012 and NeQuick2 models from 70 to 2000 km above the earth surface. The hour of the day and the day number of the year, R12, were chosen as inputs for the calculation techniques to take into account latitudinal, diurnal and seasonal variation of TEC. The results of latitudinal variation of TE

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Tue Jan 20 2026
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Comparative Histopathological Study of Ciprofloxacin Impact on Mus Musculus Renal Cortex Infected with Multi-drug Resistance and Susceptible Uropathogenic Escherichia Coli
...Show More Authors

Urinary tract infections are mainly caused by uropathogenic Escherichia coli, which represent a significant global issue along with the rising of antibiotic resistance and treatment challenges. The aim of this study was to evaluate ciprofloxacin efficacy as a treatment in animal models following infection with multidrug-resistant UPEC and multidrug-susceptible UPEC and to determine the nephrotoxic effect of these antibiotics on the renal cortex. Up to 76 E. coli isolates were collected from UTI patients in Baghdad province, characterized by morphological and biochemical features, and confirmed using the Vitek-2 compact system. Mice were orally infected via gastric gavage with G33 using a bacterial load of 107 cells/ml, followed by p

... Show More
View Publication
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
International Journal Of Applied Science And Engineering
The effect of model scale, acceleration history, and soil condition on closed-ended pipe pile response under coupled static-dynamic loads
...Show More Authors

This paper analyzes the effect of scaling-up model and acceleration history on seismic response of closed-ended pipe pile using a finite element modeling approach and the findings of 1 g shaking table tests of a pile embedded in dry and saturated soils. A number of scaling laws were used to create the numerical modeling according to the data obtained from 1 g shake table tests performed in the laboratory. The current study found that the behaviors of the scaled models, in general have similar trends. From numerical modeling on both the dry and saturated sands, the normalized lateral displacement, bending moment, and vertical displacement of piles with scale factors of 2 and 35 are less than those of the pile with a scale factor of 1 and the

... Show More
Scopus (17)
Crossref (11)
Scopus Crossref
Publication Date
Thu Dec 14 2023
Journal Name
Optical And Quantum Electronics
Enhancing response characteristics of palladium-doped vanadium pentoxide on a porous silicon substrate as gas sensor synthesized by pulsed laser deposition
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Mon Jul 01 2019
Journal Name
Ceramics International
Surface structural features and optical analysis of nanostructured Cu-oxide thin film coatings coated via the sol-gel dip coating method
...Show More Authors

View Publication
Scopus (40)
Crossref (45)
Scopus Clarivate Crossref
Publication Date
Fri Jul 19 2024
Journal Name
Applied Science And Engineering Progress
Multicomponent Equilibrium Isotherms and Kinetics Study of Heavy Metals Removal from Aqueous Solutions Using Electrocoagulation Combined with Mordenite Zeolite and Ultrasonication
...Show More Authors

Combining different treatment strategies successively or simultaneously has become recommended to achieve high purification standards for the treated discharged water. The current work focused on combining electrocoagulation, ion-exchange, and ultrasonication treatment approaches for the simultaneous removal of copper, nickel, and zinc ions from water. The removal of the three studied ions was significantly enhanced by increasing the power density (4–10 mA/cm2) and NaCl salt concentration (0.5–1.5 g/L) at a natural solution pH. The simultaneous removal of these metal ions at 4 mA/cm2 and 1 g NaCl/L was highly improved by introducing 1 g/L of mordenite zeolite as an ion-exchanger. A remarkable removal of heavy metals was reported

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Colloids And Surfaces A: Physicochemical And Engineering Aspects
Studies on membrane stability and extraction of ciprofloxacin from aqueous solution using pickering emulsion liquid membrane stabilized by magnetic nano-Fe2O3
...Show More Authors

View Publication
Scopus (55)
Crossref (48)
Scopus Clarivate Crossref
Publication Date
Mon Jul 01 2024
Journal Name
Ecological Engineering & Environmental Technology
Elimination of Methyl Orange Dye with Three Dimensional Electro-Fenton and Sono-Electro-Fenton Systems Utilizing Copper Foam and Activated Carbon
...Show More Authors

This study deals with the elimination of methyl orange (MO) from an aqueous solution by utilizing the 3D electroFenton process in a batch reactor with an anode of porous graphite and a cathode of copper foam in the presence of granular activated carbon (GAC) as a third pole, besides, employing response surface methodology (RSM) in combination with Box-Behnk Design (BBD) for studying the effects of operational conditions, such as current density (3–8 mA/cm2), electrolysis time (10–20 min), and the amount of GAC (1–3 g) on the removal efficiency beside to their interaction. The model was veiled since the value of R2 was high (>0.98) and the current density had the greatest influence on the response. The best removal efficiency (MO Re%)

... Show More
View Publication Preview PDF
Scopus (5)
Crossref (4)
Scopus Crossref