This study investigated the treatment of dairy wastewater using the electrocoagulation method with iron filings as electrodes. The study dealt with real samples collected from local factory for dairy products in Baghdad. The Response Surface Methodology (RSM) was used to optimize five experimental variables at six levels for each variable, for estimating chemical oxygen demand (COD) removal efficiency. These variables were the distance between electrodes, detention time, dosage of NaCl as electrolyte, initial COD concentration, and current density. RSM was investigated the direct and complex interaction effects between parameters to estimate the optimum values. The respective optimum value was 1 cm for the distance between electrodes, (60 – 120) min for detention time, 250 mg NaCl/L added, C0/6 = 5,775 mg COD/L as initial COD concentration, and 7.884 - 8.077 mA/cm2 as current provided. At the optimum parameter values, the optimum COD removal efficiency was 73.4%. Meanwhile, the study also performed removal efficiency for nitrogen (N) and phosphate (P) due to their effects on the aquatic life and systems. The optimum removal efficiency for phosphorus and nitrogen was 98.0% and 80.3%, respectively. Due to its effects on the environment and to comply with local legislations, treating these wastewaters using eco-friendly processes was highly recommended taking in consideration the economic feasibility, flexibility and easiness to operate. In addition, the study proved that the high surface area for iron filings played a crucial role in removing process.
The high viscosity of heavy oil is a crucial factor that strongly affects its up-stream recovering, down-stream surface transporting and refining processes. Economical methods for recovering the heavy oil and reducing is very important and related to capital and/or operating cost. This research studies the treatment of Iraqi heavy crude oil, which characterize with high viscosity and low API which makes transportation of heavy crude oil a difficult mission, needs for treatment to reduce viscosity for facilitating transportation and processing. Iraqi heavy crude oil was used Sharqi Baghdad, which obtained from Baghdad east oil fields with API 22.2º.Many kinds of additives were used to reduce the viscosity, experiments were performed o
... Show Moreِabstract:In this research we prepared nanofibers by electrospinning from poly (Vinyl Alcohol) /TiO2. The spectrum of the solution (Emission) was studied and found to be at 772 nm, several process parameters were such as concentration of TiO2 , and the effect of distance from nozzle tip to the grounded collector (gap distance). The result of the lower concentration of, the smaller the diameter of nanofiber is. Increasing the gap distance will affect nanofibers diameter.
In this paper the behavior of the quality of the gradient that implemented on an image as a function of noise error is presented. The cross correlation coefficient (ccc) between the derivative of the original image before and after introducing noise error shows dramatic decline compared with the corresponding images before taking derivatives. Mathematical equations have been constructed to control the relation between (ccc) and the noise parameter.
A simple, accurate and rapid method for separation and determination of most commonly usedinsecticides in Iraq [thiamethoxam (Thi), imidacloprid (Imi), indoxacarb (Ind), and abamectin (Aba)] ispresented. The separation was performed by gradient reversed-phase high performance liquidchromatography on a C18 stationary phase column. The method was developed and validated. The-1mobile phase was a mixture of acetonitrile and water using gradient flow. The flow rate was 1.0 mL min .The optimum temperature of separation was 25 ºC. The detection was performed at multiple wavelengths.The analysis time was up to 10.5 minutes with retention times of 3.221, 3.854, 6.385, and 9.452 min for-1the studied insecticides. The linearity was in the range of 0.
... Show MoreLeishmaniasis is endemic ofIraq in both cutaneous and visceral form. The available tools for diagnosis and detection of Leishmaniaare nonspecific and may interfere with other species. In this study, Polymerase Chain Reaction (PCR) has been used to identify Iraqi isolate of visceral leishmaniasis (MHOM/ IQ/2005/MRU15) which a previously diagnosed by classical serological tests. PCR amplificationwas carried out using species-specific primers of Leishmania donovani. Four primer pairs of mini-circle DNA and ITS-1 were used.13A/13B, which is used to identify Leishmaniaas a genus, NM12, LITSR/L5.8S and BHUL18S, were used to detect the sub species of L. donovani.The result ofPCR
... Show MoreMR Younus, Al-A'DAB, 2011