A freshwater bivalve plays a crucial function in aquatic habitats as the filtered water and burrowing mussels mix the sediment, thus increasing oxygen content and making the ecosystem healthier. The aim of the study is to see how chlorpyrifos affects biochemical markers in freshwater mussel Unio tigridis. About 180 individuals per taxon and water samples were collected from the Qandil water resource on the Greater Zab River, Erbil Province, Iraq. Once arrived at the lab, the individuals were kept in aquaria with river water and an air-conditioned room Temperature: 25±2 and Light: 12h/12h and acclimatized to laboratory conditions for seven days in aged tap water. The mussel's identification molecularly and the DNA sequence of the mussel includes U. tigridis supplied gene bank accession number ON872361, ON872362, ON872363, and ON872364 nucleotide sequencing. The 96-h toxicity of chlorpyrifos pesticide in the freshwater mussel U. tigridis was investigated using various nominal concentrations, including 50, 100, 200, 300 and 400 ppm. The water quality of the river and aquaria was tested for physicochemical parameters including water temperature, the potential of hydrogen ion pH, electrical conductivity EC, and total dissolved solids TDS, dissolved oxygen, total alkalinity, total hardness, calcium ion, magnesium ion. Water quality results of aquaria revealed that most tested variables were favorable for the breeding of mussels. The mortality of the mussels was observed daily and the 96 h LC50 value for mussels was 157.99 ppm. Within the tissue of the gills, Acetylcholinesterase (AChE), Glutathione S-transferase (GST), Catalase (CAT), and Malondialdehyde (MDA) were determined. The chlorpyrifos exposures caused significant increases in GST, CAT, and MDA. The elevation of oxidative stress biomarkers was inversely related to the AChE inhibition in the examined species. In conclusion water pollution by chlorpyrifos lead to unsafe condition for aquatic taxa.
Objectives: This study aimed to identify and study most properties of the specific and general health-related
quality-of-life (HRQoL) in prostate cancer patients, as well as creating a new measurement scale for assessing QoL
among prostate cancer patients.
Methodology: A cross sectional (descriptive) study was conducted to evaluate General Quality of life in patients
with prostate cancer. A sample of 100 prostate cancer patients from Al-Amal National hospital for cancer
management and Oncology Center in Baghdad Medical City. This study applied format of General World Health
Organization Quality of Life-BERF questionnaire. The methods used descriptive statistics to evaluate the General
QoL-Improvements, as well as inf
The corrosion inhibition effect of a new furan derivative (furan-2-ylmethyl sulfanyl acetic acid furan-2-ylmethylenehydrazide) on mild steel in 1.0 M HCl was investigated using corrosion potential (ECORR) and potentiodynamic polarization. The obtained results indicated that the new furan derivative (furan-2-ylmethyl sulfanyl acetic acid furan-2-ylmethylenehydrazide) (FSFD) has a promising inhibitive effects on the corrosion of mild steel in 1.0 M HCl across all of the conditions examined. The density functional theory (DFT) study was performed on the new furan derivative (FSFD) at the B3LYP/6-311G (d, p) basis set level to explore the relation between their inhibition efficiency and molecular electro
The effect of applied current on protection of carbon steel in 0.1N NaCl solution (pH=7) was investigated under flow conditions (0-0.262 m/s) for a range of temperatures (35-55°C) using rotating cylinder electrode. Various values of currents were applied to protect steel from corrosion, these were Iapp.=Icorr., Iapp.=2Icorr. and Iapp.=2.4Icorr. under stationary and flow conditions. Corrosion current was measured by weight loss method. The variation of protection potential with time and rotation velocity at various applied currents was assessed. It is found that the corrosion rate of carbon steel increases with rotation velocity and
has unstable trend with temperature. The protection current required varies with temperature and it inc
The distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis
... Show MoreCommercial, industrial, and military activity, largely in the 19th and 20th centuries, have led to environmental pollution that can threaten human health and ecosystem function, liquid gas petroleum (LPG) products are the major sources of energy for industry and daily life that cause environmental contamination during various stages of production, transportation, refining and use. Screening of bacterial isolate by using clear zone techniques and biomass and optical density. Results revealed that isolate Burkholdaria cepatia showed a high ability for hydrocarbons biodegradation and this isolate identified depending on morphological cultural, gram stain, microscopic features, biochemical tests, and VITEK2 compact. In this study,
... Show MoreCarbon dioxide geo-sequestration (CGS) into sediments in the form of (gas) hydrates is one proposed method for reducing anthropogenic carbon dioxide emissions to the atmosphere and, thus reducing global warming and climate change. However, there is a serious lack of understanding of how such CO2 hydrate forms and exists in sediments. We thus imaged CO2 hydrate distribution in sandstone, and investigated the hydrate morphology and cluster characteristics via x-ray micro-computed tomography in 3D in-situ. A substantial amount of gas hydrate (∼17% saturation) was observed, and the stochastically distributed hydrate clusters followed power-law relations with respect to their size distributions and surface area-volume relationships. The layer-
... Show More