Preferred Language
Articles
/
bsj-7822
Simultaneous Determination of Binary Mixture of Estradiol and Progesterone Using Different Spectrophotometric Methods
...Show More Authors

Four rapid, accurate and very simple derivative spectrophotometric techniques were developed for the quantitative determination of binary mixtures of estradiol (E2) and progesterone (PRG) formulated as a capsule. Method I is the first derivative zero-crossing technique, derivative amplitudes were detected at the zero-crossing wavelength of 239.27 and 292.51 nm for the quantification of estradiol and 249.19 nm for Progesterone. Method II is ratio subtraction, progesterone was determined at λmax 240 nm after subtraction of interference exerted by estradiol. Method III is modified amplitude subtraction, which was established using derivative spectroscopy and mathematical manipulations. Method IIII is the absorbance ratio technique, absorbance of both medicines was measured at two wavelengths λ1= 260, -absorptive point and λ2=240max of progesterone. The Q equations were used to calculate the final concentrations. The calibration curve is linear from 5.0–140 and 2.0–32.0 µg/ml for estradiol and progesterone respectively. The proposed techniques' selectivity was tested using synthetic combinations created in the lab and assessed using the standard addition method. Using one-way ANOVA, the outputs of the proposed ways were compared, and the result showed no significant differences between the proposed techniques.

Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Oct 29 2023
Journal Name
Iraqi National Journal Of Nursing Specialties
Determination of Job Stress among Nurses in Cardiac Surgical Intensive Care Units in Baghdad City
...Show More Authors

Objective: The study aimed to determine the sources and level of job stress experienced by nurses who were
working in intensive care units, and to find-out the relationship between work-related stress and some variables
such as age, gender, educational level, marital status, and years of experience in cardiac surgical intensive care
unit.
Metl]odo]ogy: A descriptive study was conducted on nurses working in the cardiosurgical intensive care units in
Baghdad hospitals. The study sample was selected purposively and consisted of (60) nurses who were working
in cardiosurgical intensive care units in Baghdad city (Ibm Al-Betar Hospital for Cardiac Surgery, Ibn A1-Nafis
Hospital for Cardiovascular Diseases, and the Iraqi Ce

... Show More
View Publication Preview PDF
Publication Date
Wed Jul 22 2020
Journal Name
International Journal Of Research In Pharmaceutical Sciences
Cloud point extraction method for the sensitive determination of metoclopramide hydrochloride in pharmaceutical dosage forms
...Show More Authors

In this work, a simple and very sensitive cloud point extraction (CPE) process was developed for the determination of trace amount of metoclopramide hydrochloride (MTH) in pharmaceutical dosage forms. The method is based on the extraction of the azo-dye results from the coupling reaction of diazotized MTH with p-coumaric acid (p-CA) using nonionic surfactant (Triton X114). The extracted azo-dye in the surfactant rich phase was dissolved in ethanol and detected spectrophotometrically at λmax 480 nm. The reaction was studied using both batch and CPE methods (with and without extraction) and a simple comparison between the two methods was performed. The conditions that may be affected by the extraction process and the sensitivity of m

... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Mon Apr 28 2025
Journal Name
Chemical Papers
New chemiluminometric method for the determination of azithromycin in a continuous flow injection analysis system
...Show More Authors

A novel analytical method is developed for the determination of azithromycin. The method utilizes continuous flow injection analysis to enhance the chemiluminescence system of luminol, H2O2, and Cr(III). The method demonstrated a linear dynamic range of 0.001–100 mmol L-1 with a high correlation coefficient (r) of 0.9978, and 0.001–150 mmol L-1 with a correlation coefficient (r) of 0.9769 for the chemiluminescence emission versus azithromycin concentration. The limit of detection (L.O.D.) of the method was found to be 18.725 ng.50 µL−1 based on the stepwise dilution method for the lowest concentration within the linear dynamic range of the calibration graph. The relative standard deviation (R.S.D. %) for n = 6 was less than 1.2%

... Show More
View Publication
Scopus (1)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Sun Jan 03 2021
Journal Name
مجلة كلية التراث الجامعة
قياس وتحليل الاستدامة المالية للاقتصاد العراقي للمدة ٢٠٠٤-٢٠١٨
...Show More Authors

ان تحليل السلاسل الزمنية من المواضـيع الهامة في تفسير الظـواهر التي تحدث خلال فترة زمنية معينة ان الهدف من هذا لتحليل هو الحصـول على وصف وبنـاء أنموذج مناسب من اجل اعطاء صورة مستقبلية واضحة للسلاسل الزمنية المدروسة وان السلاسل الزمنية اهم الادوات المستخدمة في بناء وتقدير والتنبؤ بالظواهر المختلفة وان الاستدامة المالية هي الحالة التي تكون فيها الدولة قادرة على الوفاء بالتزاماتها الحالية والمستقبلية من غير

... Show More
Publication Date
Tue Sep 27 2022
Journal Name
Al–bahith Al–a'alami
Obstacles to employing social media applications in measuring public opinion
...Show More Authors

Media and communication's research are varied in accordance to research approaches' variety which seeks to reach convergent social, psycholo

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jan 01 2017
Journal Name
Al-mustansiriyah Journal Of Science
Development of Dispersive Liquid-Liquid Microextraction method combined with UV spectrophotometry for the Determination of Malathion Pesticide
...Show More Authors

A simple and novel method was developed by combination of dispersive liquid-liquid microextraction with UV spectrophotometry for the preconcentartion and determination of trace amount of malathion. The presented method is based on using a small volume of ethylenechloride as the extraction solvent was dissolved in ethanol as the dispersive solvent, then the binary solution was rapidly injected by a syringe into the water sample containing malathion. The important parameters, such the type and volume of extraction solvent and disperser solvent, the effect of extraction time and rate, the effect of salt addition and reaction conditions were studied. At the optimum conditions, the calibration graph was linear in the range of 2-100 ng mL-1 of ma

... Show More
Publication Date
Thu Jan 30 2025
Journal Name
Iraqi Journal Of Science
Development of A New Colorimetric-Flow System Approach for The Determination of Cefotaxime Sodium in Pharmaceutical Formulations
...Show More Authors

     A new colorimetric-flow injection method has been developed and validated for the detection of Cefotaxime sodium in pharmaceutical formulations. This method stands out for its rapid and sensitive nature. The formation of a brown-colored complex between Cefotaxime sodium and the Biuret reagent in a highly alkaline environment serves as the basis for the detection. The intensity of this colored complex is measured using a custom-built Continuous Flow Injection Analyzer, enabling accurate quantification of Cefotaxime sodium. Optimization studies of the chemical and physical parameters such as dilution of Biuret reagent, effect of the medium basicity, flow rate, sample loop and others have been investigated. The calibration gra

... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Chemical Methodologies
Determination of the Quantity of Losartan Active Ingredient in the Medication Formulations via Turbidimetric-Flow Injection Technique
...Show More Authors

Scopus (16)
Scopus
Publication Date
Sat Mar 01 2008
Journal Name
Iraqi Journal Of Physics
The Determination of Lower Limit Detection of X-Ray Fluorescence for Zinc Powder Suspended in Engine Oil
...Show More Authors

In this work Different weight of pure Zinc powder suspended particles in 4ml base engine Oil were used.
Intensity of Kα Line was measured for the suspended particles ,also for mixture which consist from Zinc particle blended with Engine base Oil. Calibration Curve was drawn between Ikα line Intensity and Zinc concentration at different operation condition. The Lower Limit detection (LLD) and Sensitivity (m) of Spectrometer were determined for different Zinc Concentration (Wt%). The results of LLD and m for Samples were analyzed at Operation Condition of 30KV,17mA is best from Samples were analyzed at Operation Condition of 25KV,15mA

View Publication Preview PDF
Publication Date
Fri Nov 01 2019
Journal Name
Iop Conference Series: Earth And Environmental Science
The comparison of several methods for calculating the degree of heritability and calculating the number of genes in maize (Zea mays L.). I. Agronomic traits
...Show More Authors
Abstract<p>The objective of present study was to compare of several methods for estimating the degree of heritability and calculating the number of genes using generation mean analysis of maize (<italic>Zea mays</italic>L.). The experiment was conducted at the field of Field Crop Dept. College of Agric / Univ. of Baghdad, for many seasons, spring and fall seasons 2009, 2010, spring 2011 and fall 2013.Six diverse inbred lines were crossed to produce F1,F2,BC1 and BC2 for four superior crosses.Broad-sense and narrow sense heritability estimates based on variance of different generations. The results showed that the four formulas used to estimate the heritability were different in estimating the values o</p> ... Show More
View Publication
Scopus (5)
Scopus Crossref