This study has been done on plant [Adhatoda vasicia , Acanthaceae family],which has been collected from gardens of university of Baghdad The leaves of plant were extracted by methanol alcohol obtain the crude extraction good ratio(30%).Eighty swabs or samples were collected from several wounds patients of hospitals in Baghdad city.These swabs were cultured on blood and MacConkey ager to isolate bacteria and identified by appearance and bio chemical tests.The results showed that(60)somples were positive(75%)for tests bacteria white the other(20)swabs were negative(25%).The bacteria were identified as Pseudomonas aeruginosa ,Staphylococcus awreus , Esherichia coli,Proteus spp and Klebsiella spp; and their number percentage were(32)isolates(49.2 %),(7)isolates(10.7%),(5)isolates(7.6%),(1)isolate(1.5%)and(20)isolates(30.7%)respectivity.Crude extract teated by sensitivity test against the bacteria with concentration (2,4,6,8,10,12mg/ml).The results showed that the inhibition zone increased with increasing ils concentration The best concentration that inhited most of the bacteria is(6 mg/ml) of the crud extract that was isolated from wounds .
The ciliate species isolated from midgut and hindgut of Rough-tailed gecko Cyrtopodion scabrum (Heyden, 1827), identified as Nyctotherus hardwickii was collected from many regions of Baghdad, Iraq. The current study deals with a description and comparison of the morphology and morphometric characters of this species for the first time in Iraq.
Two main grand bus national stations in Baghdad ( Alawi-alhila and Bab-almudam) were chosen as examples to determine lead effect on its drivers. This lead came from ethyl tetra lead or ethyl tri lead which used to improve gasoline quality ,so these two stations could be consider as two of the most polluted places due to gasoline burned by hundreds cars located in these stations .The determination of environmental lead pollution was measured in blood and urines drivers. Drivers were divided in two main groups due to their ages ( 30 persons in each group). The first group for men of 22-30 years old. The second group for men of 40-60 years old. Those men were carefully chosen in order to be non-fumiers or non-alcoholics persons because of
... Show MorePhotonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and the characterization of a relative humidity sensor based on a polymer-coated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) transmission mode. The fabrication of the sensor involved splicing a short (1 cm) length of Photonic Crystal Fiber (PCF) between two single-mode fibers (SMF). It was then coated with a layer of agarose solution. Experimental results showed that a high humidity sensitivity of 29.37 pm/%RH was achieved within a measurement range of 27–95%RH. The sensor also showed good repeatability, small size, measurement accuracy and wide humidity range. The RH sensitivity o
... Show MoreThis study examined the relationship between the reporting lag (the timeliness of corporate financial reporting) and several independent variables: (1) Audit reporting lag,(2)Company Size,(3) Profitability of the company,(4)Company Age,(5) Sector Type.(6)Audit’s Opinion,(7) Market Type,(8) Gearing,(9) Concentration of ownership,(10) Audit Firm Size(11)Profit or Loss Company(12) Companies Listed lag on the PEX. In order to achieve the objectives of the study and testing its hypotheses, the data Obtained through actual data of a financial reports, and based on me
... Show MoreObjectives: To assess the performance of a novel resin-modified glass-ionomer cement (pRMGIC) bonded to various tooth tissues after two-time intervals. Methods: 192 sound human molars were randomly assigned to 3 groups (n = 64): sound enamel, demineralised enamel, sound dentine. Sixty-four teeth with natural carious lesions including caries-affected dentine (CAD) were selected. All substrates were prepared, conditioned and restored with pRMGIC (30% ethylene glycol methacrylate phosphate (EGMP, experimental), Fuji II LC (control), Fuji IX, and Filtek™ Supreme with Scotchbond ™ Universal Adhesive. Shear bond strength (SBS) was determined after 24 h and three months storage in SBF at 37C. The debonded surfaces were examined using stereomi
... Show MoreA fixed firefighting system is a key component of fire safeguarding and reducing fire danger. It is installed as a permanent component in a structure to protect the entire or a portion of the building and its contents. The study aims to review the previous studies that deal with the evaluation of fire safety measures and their use in resolving problems associated with fire threats in buildings. For this reason, a number of previous studies in this field were reviewed compared with the NFPA code. The findings revealed that regulatory developments over the last several decades had created an atmosphere conducive to innovation. This has resulted in a growth in the number of fixed firefighting system types now obtainable. Th
... Show MoreWhile hepatitis viruses A–E are established, emerging evidence points to additional, novel viral hepatitis agents. The torqueteno virus (TTV) has garnered interest due to its prevalence among patients with hepatitis, suggesting potential hepatotropism.
This study was conducted to detect TTV antigens in individuals infected with chronic hepatitis B (HBV) and/or C (HCV) using molecular diagnostics and to explore any associations between TTV presence and demographic characteristics of the cohort.
This study aims to establish an empirical correlation between biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) of the sewage flowing in Al-Diwaniyah wastewater treatment plant. The strength of the wastewater entering the plant varied from medium to high. High concentrations of BOD5 and COD in the effluent were obtained due to the poor performance of the plant. This was observed from the BOD5 /COD ratios that did not confirm with the typical ratios for the treated sewage. To improve the performance of this plant, regression equations for BOD5 and COD removal percentages were suggested which can be used to facilitate rapid effluent assessment or optimal process control. The equations relating the percentage removal of
... Show More