In this work, an enhanced Photonic Crystal Fiber (PCF) based on Surface Plasmon Resonance (SPR) sensor using a sided polished structure for the detection of toxic ions Arsenic in water was designed and implemented. The SPR curve can be obtained by polishing the side of the PCF after coating the Au film on the side of the polished area, the SPR curve can be obtained. The proposed sensor has a clear SPR effect, according to the findings of the experiments. The estimated signal to Noise Ratio (SNR), sensitivity (S), resolution (R), and Figures of merit (FOM) are approaching; the SNR is 0.0125, S is 11.11 μm/RIU, the resolution is 1.8x〖10〗^(-4), and the FOM is 13.88 for Single-mode Fiber- Photonic Crystal Fiber- single mode Fiber (SMF-PCF-SMF). While the effective performance parameters for Multi-Mode Fiber- Photonic Crystal Fiber- Multi-Mode Fiber (MMF-PCF-MMF) such as the sensitivity is approaching 9.5 μm/RIU, SNR is 0.0173, FOM is10.86 and the resolution is 4x〖10〗^(-4) is achieved. The concentrations were calculated practically and theoretically for each of the sensors, and it was found that the practical concentrations that were obtained are close or equal to the concentrations that were theoretically obtained through the dilution law, where the concentrations were obtained 0.096, 0.15, 0.26, 0.38, 0.49 practically and 0.1, 0.2 and 0 3, 0.4 and 0.5 theoretically For SMF-PCF-SMS, concentrations of 0.089, 0.16, 0.23, 0.34, and 0.45 were practically obtained, and 0.1, 0.2, 0.3, 0.4, and 0.5 theoretically for MMF-PCF-MMF. The suggested sensor has a strong mechanical structure, low cost, and easy fabrication, allowing it to provide a greater measurement range and action area to the measured samples without lengthening the sensor.
In this research, optical communication coding systems are designed and constructed by utilizing Frequency Shift Code (FSC) technique. Calculations of the system quality represented by signal to noise ratio (S/N), Bit Error Rate (BER),and Power budget are done. In FSC system, the data of Nonreturn- to–zero (NRZ ) with bit rate at 190 kb/s was entered into FSC encoder circuit in transmitter unit. This data modulates the laser source HFCT-5205 with wavelength at 1310 nm by Intensity Modulation (IM) method, then this data is transferred through Single Mode (SM) optical fiber. The recovery of the NRZ is achieved using decoder circuit in receiver unit. The calculations of BER and S/N for FSC system a
... Show MoreThe purpose of this research is to identify the effect of the use of project-based learning in the development of intensive reading skills at middle school students. The experimental design was chosen from one group to suit the nature of the research and its objectives. The research group consisted of 35 students. For the purpose of the research, the following materials and tools were prepared: (List of intensive reading skills, intensive reading skills test, teacher's guide, student book). The results of the study showed that there were statistically significant differences at (0.05) in favor of the post-test performance of intensive reading skills. The statistical analysis also showed that the project-based learning approach has a high
... Show MoreThe objective of this work is to study the influence of end milling cutting process parameters, tool material and geometry on multi-response outputs for 4032 Al-alloy. This can be done by proposing an approach that combines Taguchi method with grey relational analysis. Three cutting parameters have been selected (spindle speed, feed rate and cut depth) with three levels for each parameter. Three tools with different materials and geometry have been also used to design the experimental tests and runs based on matrix L9. The end milling process with several output characteristics is solved using a grey relational analysis. The results of analysis of variance (ANOVA) showed that the major influencing parameters on multi-objective response w
... Show MoreLongitudinal data is becoming increasingly common, especially in the medical and economic fields, and various methods have been analyzed and developed to analyze this type of data.
In this research, the focus was on compiling and analyzing this data, as cluster analysis plays an important role in identifying and grouping co-expressed subfiles over time and employing them on the nonparametric smoothing cubic B-spline model, which is characterized by providing continuous first and second derivatives, resulting in a smoother curve with fewer abrupt changes in slope. It is also more flexible and can pick up on more complex patterns and fluctuations in the data.
The longitudinal balanced data profile was compiled into subgroup
... Show MoreIn this work, the fractional damped Burger's equation (FDBE) formula = 0,
The study of determing Uranium concentration in samples of teeth is the first of its kind in the Iraq . In this study Uranium concentration has been measured was (32) samples of child teeth distributed on the some of middle and south governorate of Iraq (Muthana – Dekar – Basrah – Najaf – Karbalah – Waset – Babel – Baghdad) . The Uranium concentration in teeth samples has been measured by using fission tracks registration in (CR-39) track detector that caused by the bombardment of (U235) with thermal neutrons falx from (24Am.Be) neutron source that has flux of (5x103n.cm-2S-1). The result obtained show that the Uranium concentrations in governorates were (0.18ppm), (0.172ppm), (0.160ppm), 0.150ppm) (0.89ppm), (0.07ppm) , (0.
... Show MoreMercury, arsenic, cadmium and lead, were measured in sediment samples of river and marine environmental of Basra governorate in southern of Iraq. Sixteen sites of sediment were selected and distributed along Shatt Al-Arab River and the Iraqi marine environment. The samples were distributed among one station on Euphrates River before its confluence with Tigris River and Shatt Al-Arab formation, seven stations along Shatt Al-Arab River and eight stations were selected from the Iraqi marine region. All samples were collected from surface sediment in low tide time. ICP technique was used for the determination of mercury and arsenic for all samples, while cadmium and lead were measured for the same samples by using Atomic Absorption Spectrosc
... Show More