Staphylococcus Sp.is the most common type of bacteria found in contamination place, we design this
study to compare the contamination accident between two hospitals in Baghdad.One of them isthe Burns
Specialist Hospital in the Medical CityinRusafa and another one is Al-Karama Hospital in Karkh. The
samples were collected fromOperativeWard No1 (OW1), Operative Ward No2 (OW2), Consulting Pharmacy
(CP), Emergency Room (ER), Reception Room (RR), Women's Ward (WW) and Men's Ward (MW).The
samples were taken from inside each clinical unit, surfaces, food, and air. The results showed that the
number of samples containing Staphylococcus sp. bacteria is 81, including 45 belonging to Al-Karama Burns
Ward Hospital and 36 belonging to the Medical City Hospital, Burns Special Hospital. The results of
Medical City Hospital showed that Staphylococcus sp.isolates resist many antibiotics, 99.99% of the isolates
from patient samples were resistant to(CLR, P, AMP); 92.30% of the isolates from air samples were resistant
to(P, MET) and 85.71%of isolates from surfaces and food samples were resist for (AMP, MET). Also the
results of Al-KaramaHospital showed that the highest resistance in the staphylococcus sp.isolateswere in
patient samplesfor (AMP, SXT), in surface samples for (E), in food samples for (E,P) and in air samples for
(P) and the resistance rates were 100% to all these antibiotics.
Background: Beta thalassemia major is an inherited disorder that may affect general and oral health.The purpose of this study was toassess the severity of dental caries in relation to oral cleanliness, mutans streptococciamong a group of boys with beta thalassemia majorin comparison with a control group. Materials and Methods: The study involved 30 boys with BTM aged 10-12 years compared to 30 healthy boys with the same age group. d1-4mfs and D1-4 MFS indices were applied (Muhlemann, 1976), the viable counts of mutans streptococci in stimulated saliva were also determined. Results: The entire thalassemic group was caries-active. For both dentitions, a higher dmfs/DMFS values were recorded for study compared to control group, difference was
... Show MoreVisceral leishmaniasis(VL) or kala-azar is one of the world most neglected tropical diseases in mortality and fourth in morbidity, rK39 dipstick was used to diagnose the suspected infected patients as easiest and rapid technique for VL diagnostic, the disease out-coming required to the differentiation of cell mediated immunity either T-helper 1(Th-1) or (Th-2). One of main pointers that may be considered as one of immune evasion strategy in the host-parasite interplay is HLA-G level alteration. HLA-G Known as a special proteins (non-classical HLA class I) molecules which can suppress the immune system by T-cell functions impaired in the aid with target receptors as LILRB4. The development of the cell mediated immunity initiated with Interle
... Show MoreDesign and build a center basins new p-type four mirrors were studied its effect on all parameters evaluating the performance of the solar cell silicon in the absence of a cooling system is switched on and noted that the efficiency of the performance Hzzh cell increased from 11.94 to 21 without cooling either with cooling has increased the efficiency of the
Abstract: Background: Staphylococcus aureus is Gram-positive bacteria that lives as a normal flora in living organisms but can be pathogenic to humans. Although a relatively unspectacular, nonmotile coccoid bacterium, S. aureus is a dangerous human pathogen in both community-acquired and nosocomial infections. Due to the increasing emergence of new strains of this antibiotic-resistant bacteria, it has become essential to approach different methods to control this pathogen. One of these methods is the antimicrobial photodynamic inactivation process using a low-level laser, in this paper, the Photodynamic effects of Rose Bengal and LLLL on the virulence factors of S.aureus were evaluated.
In wide range of chemical, petrochemical and energy processes, it is not possible to manage without slurry bubble column reactors. In this investigation, time average local gas holdup was recorded for three different height to diameter (H/D) ratios 3, 4 and 5 in 18" diameter slurry bubble column. Air-water-glass beads system was used with superficial velocity up to 0.24 m/s. the gas holdup was measured using 4-tips optical fiber probe technique. The results show that the axial gas holdup increases almost linearly with the superficial gas velocity in 0.08 m/s and levels off with a further increase of velocity. A comparison of the present data with those reported for other slurry bubble column having diameters larger than
... Show More