Erbil city is located in the northern Iraq with a population of over one million people. Due to water crises farmers usually use wastewater and well water for the agricultural production. In this study six stations were designed to sample waste water and three from well water to define waste water and ground water characteristics. In this study, Residual Na+ Carbonate, Mg++ hazard, salinity hazard, Kelley index, %sodium, total hardness, permeability index, potential salinity, sodium adsorption ratio, and Irrigation Water Quality Index (IWQI) were determined. The order of average cation concentrations in water was Mg2+> Ca2+ > Na+ > K+. While the proportion of main anions in water were HCO3 >SO4 > Cl. The highest concentrations of Ca2+, Mg2+ and Na+ were found in well water, while the highest concentration of K+ was found in wastewater. The maximum concentration of HCO3 and Cl recorded in well water, while the highest concentration SO4 recorded in wastewater. Moreover, the order of trace elements was Pb > Al > Fe > Cd > As > Mn >Cr > Ag > Ni. Keeping in mind metal concentration set by US EPA and FAO (1999) and (1994) guidelines the levels of Pb, Al, Fe, Mn, Cr, Ag and Ni in the waste and well water were within the admissible limitations for irrigation schemes. Moreover, limitations of As and Cd were beyond permissible limitation need to be reduced. The IWQI ranged from 88.92 to 95.09 in the waste water samples. Overall assessment reveals that cultivated agriculture plants were secured from toxic compounds.
In the current study, a novel approach for separating ethanol-water mixture by microbubble distillation technology was investigated. Traditional distillation processes require large amounts of energy to raise the liquid to its boiling point to effect removal of volatile components. The concept of microbubble distillation by comparison is to heat the gas phase rather than the liquid phase to achieve separation. The removal of ethanol from the thermally sensitive fermentation broths was taken as a case of study. Consequently the results were then compared with those which could be obtained under equilibrium conditions expected in an “ideal” distillation unit. Microbubble distillation has achieved vapour compositions higher than th
... Show MoreThe significant shortage of usable water resources necessitated the creation of safe and non-polluting ways to sterilize water and rehabilitate it for use. The aim of the present study was to examine the ability of using a gliding arc discharge to inactivate bacteria in water. Three types of Bacteria satisfactory were used to pollute water which are Escherichia coli (Gram-negative), Staphylococcus aurous (Gram-positive) and salmonella (Gram-negative). A DC power supply 12V at 100 Hz frequency was employed to produce plasma. pH of water is measured gradually during the plasma treatment process. Contaminated water treated by gliding arc discharge at steadying the gas flow rate (1.5 l/mi
The research aims to identify ways of upgrading the quality level of university education at the Middle Technical University in light of its application for the National Ranking project for the quality of Iraqi universities in order to obtain advanced grades among the Iraqi universities , Which is qualified to enter the Ranking of universities worldwide, through displaying the mechanism of the Application of National Ranking project for the quality of Iraqi universities in the Middle Technical University and its formations consisting of (5) technical colleges and (11) technical institute.
The results of the application showed several observations: The most
... Show MoreA design for a photovoltaic-thermal (PVT) assembly with a water-cooled heat sink was planned, constructed, and experimentally evaluated in the climatic conditions of the southern region of Iraq during the summertime. The water-cooled heat sink was applied to thermally manage the PV cells, in order to boost the electrical output of the PVT system. A set of temperature sensors was installed to monitor the water intake, exit, and cell temperatures. The climatic parameters including the wind velocity, atmospheric pressure, and solar irradiation were also monitored on a daily basis. The effects of solar irradiation on the average PV temperature, electrical power, and overall electrical-thermal efficiency were investigated. The findings i
... Show MoreAcceptable Bit Error rate can be maintained by adapting some of the design parameters such as modulation, symbol rate, constellation size, and transmit power according to the channel state.
An estimate of HF propagation effects can be used to design an adaptive data transmission system over HF link. The proposed system combines the well known Automatic Link Establishment (ALE) together with variable rate transmission system. The standard ALE is modified to suite the required goal of selecting the best carrier frequency (channel) for a given transmission. This is based on measuring SINAD (Signal plus Noise plus Distortion to Noise plus Distortion), RSL (Received Signal Level), multipath phase distortion and BER (Bit Error Rate) fo
... Show MoreAn investigation of the quadrupole deformation of Kr, Sr, Zr, and Mo isotopes has been conducted using the HFB method and SLy4 Skyrme parameterization. The primary role of occupancy of single particle state 2d5/2 in the existence of the weakly bound structure around N=50 is probed. Shell gaps are performed using a few other calculations for the doubly magic number 100Sn using different Skyrme parameterizations. We explore the interplays among neutron pairing strength and neutron density profile in two dimensions, along with the deformations of 100Sn.
The objective of study was determining the most prevalent Salmonella spp. and their antimicrobial susceptibility in broilers and laying chickens and their feed and drinking water in five chicken farms in Karbala, Iraq over the period from August to October 2020. A total of 289 samples, including 217 cloaca swabs, 46 water and 26 feed samples were collected. Salmonella spp. was identified firstly by routine diagnostic methods, followed by applying the API 20E kit, the Vitek2 system, and serology. There was significant differences in Salmonella prevalence among different types of samples, mainly cloaca swabs reported a high isolation rate (21.7%). In contrast, feed samples were completely free of contamination. The highest rate of isolation w
... Show MoreObjective(s): To assess parents' attitude toward immunization and its relation with their compliance and to find out the relationship between parents' attitude and their socio-demographic characteristics.
Methodology: A descriptive design is conducted from the period of 19th September 2020 to the 6th of March 2021. A non-probability (convenient) sample of (292) parents was selected from (5) primary health care centers in Karbala city. These centers are distributed throughout (2) primary health care sectors selected randomly as (20%) from each sectors. The questionnaire is developed and composed of three parts: First part: parent's socio-demographic characteristics, Second part: parents' attitude domain, which involves (13 items), and
The aim of the present work, was measuring of uranium concentrations in 25 soil samples from five locations of Al-Kut city. The samples taken from different depths ranged from soil surface to 60cm step 15 cm, for this measurement of uranium concentrations .The most widely used technique SSNTDs was chosen to be the measurement technique. Results showed that the higher concentrations were in Hai Al- Kafaat which recorded 1.49 ± 0.054 ppm . The uranium content in soil samples were less than permissible limit of UNSCEAR(11.7ppm).
This study was done to determine the concentration of several heavy metals in the water of Al-Saddah agricultural drainage in Al-Saddah District in Babylon Province/Iraq. The concentrations of six heavy metals were measured (Pb, Cd, Cu, Hg, Fe, Zn). It was found that Pb concentration ranged from 0.06 mg/L at St.2 in autumn to 0.13 mg/L at St.2 in winter. Fe concentrations ranged from 0.04 mg/L at St.2 in autumn and winter to 0.41 at St.2 in Summer. Cd concentrations ranged from 0.008 mg/L at St.2 in summer to 0.05 mg/L at St.2 in winter. Cu concentrations ranged from 0.01 mg/L at St.1 in both autumn and winter to 0.63 mg/L at St.2 in winter. Hg concentrations was ranged from 0.002 mg/