The current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l, and 0.48 ± 0.04-1.36 ± 0.06 with an average value of 0.88 ± 0.05 Bq/l for 232Th, while for 40K 13.00 ± 0.69-36.89 ± 1.12 with an average value of 25.1 ± 0.95 Bq/l, respectively. The results obtained from the water samples are below the safe and standard limits established by UNSCEAR. In addition to calculating the radiological hazard indicators that included Radium equivalent (Raeq), air absorbed dose rate (Dγ), effective annual equivalent dose rate (AEDE), indoor and outdoor radiation hazard (H) indices, lifetime cancer risk (ELCR), gonadotropin equivalent dose (AGDE), and ideal level index of gamma rays (Iγ) has been calculated. To verify its deleterious character. On the other hand, the results showed that the rate of heat production values ranged between 0.006-0.0015 µW/m3, which indicates a low rate of heat production and does not affect the temperature of the Earth's crust. Finally, In addition to physicochemical parameters such as PH, dissolved solids TDS, and electrical conductivity Ec. All tested data are within the permissible limit of WHO standards. The results of the current study can be used to provide essential baseline data for future epidemiological investigations and surveillance programs in the areas under study.
Produced water is accompanied with the production of oil and gas especially at the fields producing by water drive or water injection. The quantity of these waters is expected to be more complicated problem with an increasing in water cut which is expected to be 3-8 barrels water/produced barrel oil.Produced water may contain many constituents based on what is present in the subsurface at a particular location. Produced water contains dissolved solids and hydrocarbons (dissolved and suspended) and oxygen depletion. The most common dissolved solid is salt with concentrations range between a few parts per thousand to hundreds parts per thousand. In addition to salt, many produced waters also contain high levels of heavy metals like zinc, bari
... Show MoreThe application of ultrafiltration (UF) and nanofiltration (NF) processes in the handling of raw produced water have been investigated in the present study. Experiments of both ultrafiltration and nanofiltration processes are performed in a laboratory unit, which is operated in a cross-flow pattern. Various types of hollow fiber membranes were utilized in this study such as poly vinyl chloride (PVC) UF membrane, two different polyether sulfone (PES) NF membranes, and poly phenyl sulfone PPSU NF membrane. It was found that the turbidity of the treated water is higher than 95 % by using UF and NF membranes. The chemical oxygen demand COD (160 mg/l) and Oil content (26.8 mg/l) were found after treatment according to the allowable limits set
... Show MoreUrsolic acid (UA, 3 ?-hydroxy-urs-12-en-28-oic acid) are isomeric triterpenic acids. The high quantities of pentacyclic triterpenoids in Scabiosa species seems to be obvious and there is an evidence that most of pentacyclic triterpenoids that have been isolated are saponins. This is one of the most important characteristic of the genus Scabiosa, the main aglycones are ursolic acid and oleanolic acid. In the current study, isolation from the aerial part and roots of Scabiosa palaestina L. was performed using Preparative HPLC. Furthermore, detection and quantitation of ursolic acid was performed by high performance thin layer chromatography (HPTLC). The identification of isolated triterpenoid involves two methods including FT-IR coupl
... Show MoreThe distribution of chilled water flow rate in terminal unit is an important factor used to evaluate the performance of central air conditioning unit. A prototype of A/C unit has been made, which contains three terminal units with a complete set of accessories (3-way valve, 2-way valve, and sensors) to study the effect of the main parameters, such as total water flow rate and chilled water supply temperature with variable valve opening. In this work, 40 tests were carried out. These tests were in two groups, 20 test for 3-way valve case and 20 test for 2-way valve case. These tests were performed at three levels of valve opening, total water flow rate and water supply temperature according to the design matrices establis
... Show More