The current study sheds light on the measurement and estimation of the radioactivity of radionuclides (238U, 226Ra, 232Th, and 40k) in natural waters of different regions of Nineveh Governorate in Iraq.15 samples were collected from different sources of natural waters, where gamma-ray spectroscopy was used using NaI)TI) sodium iodide detector to determine the concentration of radioactivity in the samples. According to the results, the radioactivity concentration in the tested water sample were ranged from 0.36 ± 0.04-1.57 ± 0.09with an average value of 0.69 ± 0.06 Bq/l for 238U, and 2.9 ± 0.02-0.88 ± 0.03 with an average value of 0.65 ± 0.03 Bq/l for 226Ra Bq/l, and 0.48 ± 0.04-1.36 ± 0.06 with an average value of 0.88 ± 0.05 Bq/l for 232Th, while for 40K 13.00 ± 0.69-36.89 ± 1.12 with an average value of 25.1 ± 0.95 Bq/l, respectively. The results obtained from the water samples are below the safe and standard limits established by UNSCEAR. In addition to calculating the radiological hazard indicators that included Radium equivalent (Raeq), air absorbed dose rate (Dγ), effective annual equivalent dose rate (AEDE), indoor and outdoor radiation hazard (H) indices, lifetime cancer risk (ELCR), gonadotropin equivalent dose (AGDE), and ideal level index of gamma rays (Iγ) has been calculated. To verify its deleterious character. On the other hand, the results showed that the rate of heat production values ranged between 0.006-0.0015 µW/m3, which indicates a low rate of heat production and does not affect the temperature of the Earth's crust. Finally, In addition to physicochemical parameters such as PH, dissolved solids TDS, and electrical conductivity Ec. All tested data are within the permissible limit of WHO standards. The results of the current study can be used to provide essential baseline data for future epidemiological investigations and surveillance programs in the areas under study.
Concrete columns with hollow-core sections find widespread application owing to their excellent structural efficiency and efficient material utilization. However, corrosion poses a challenge in concrete buildings with steel reinforcement. This paper explores the possibility of using glass fiber-reinforced polymer (GFRP) reinforcement as a non-corrosive and economically viable substitute for steel reinforcement in short square hollow concrete columns. Twelve hollow short columns were meticulously prepared in the laboratory experiments and subjected to pure axial compressive loads until failure. All columns featured a hollow square section with exterior dimensions of (180 × 180) mm and 900 mm height. The columns were categorized into
... Show Moreلقد لاقت مواضيع استعمال التحليل الاحصاء المالي رواجاً كبيراً في الآونة الأخيرة سواء على مستوى الافراد والشركات العامة والخاصة مروراً بأسواق الاسهم والاوراق المالية (البورصات) وصولاً الى اقتصاديات الدول والبلدان. وذلك بعد وصول الباحثين والدارسين للظواهر الاقتصادية والمالية بكل أنماطها الى إدراك أهمية التحليل الكميّ عموماً والتحليل الاحصائي على وجه الخصوص، مما دفعنا لتأليف الطبعة الأولى من هذا الكتاب بالع
... Show More<span lang="EN-US">The fundamental of a downlink massive multiple-input multiple-output (MIMO) energy- issue efficiency strategy is known as minimum mean squared error (MMSE) implementation degrades the performance of a downlink massive MIMO energy-efficiency scheme, so some improvements are adding for this precoding scheme to improve its workthat is called our proposal solution as a proposed improved MMSE precoder (PIMP). The energy efficiency (EE) study has also taken into mind drastically lowering radiated power while maintaining high throughput and minimizing interference issues. We further find the tradeoff between spectral efficiency (SE) and EE although they coincide at the beginning but later their interests become con
... Show MoreThe paper presents the design of a system consisting of a solar panel with Single Input/Multiple Outputs (DC-DC) Buck Converter by using Simulink dialogue box tools in MATLAB software package for simulation the system. Maximum Power Point Tracking (MPPT) technique depending on Perturb and Observe (P&O) algorithm is used to control the output power of the converter and increase the efficiency of the system. The characteristics of the MSX-60 PV module is chosen in design of the system, whereas the electrical characteristics (P-V, I-V and P-I curves) for the module are achieved, that is affected by the solar radiation and temperature variations. The proposed design module has been found to be stable for any change in atmospheric tempera
... Show MoreThis paper presents the implementation of a complex fractional order proportional integral derivative (CPID) and a real fractional order PID (RPID) controllers. The analysis and design of both controllers were carried out in a previous work done by the author, where the design specifications were classified into easy (case 1) and hard (case 2) design specifications. The main contribution of this paper is combining CRONE approximation and linear phase CRONE approximation to implement the CPID controller. The designed controllers-RPID and CPID-are implemented to control flowing water with low pressure circuit, which is a first order plus dead time system. Simulation results demonstrate that while the implemented RPID controller fails to stabi
... Show MoreAlbizia lebbeck biomass was used as an adsorbent material in the present study to remove methyl red dye from an aqueous solution. A central composite rotatable design model was used to predict the dye removal efficiency. The optimization was accomplished under a temperature and mixing control system (37?C) with different particle size of 300 and 600 ?m. Highest adsorption efficiencies were obtained at lower dye concentrations and lower weight of adsorbent. The adsorption time, more than 48 h, was found to have a negative effect on the removal efficiency due to secondary metabolites compounds. However, the adsorption time was found to have a positive effect at high dye concentrations and high adsorbent weight. The colour removal effi
... Show More