An easy, eclectic, precise high-Performance Liquid Chromatographic (HPLC) procedure was evolved and validated to estimate of Piroxicam and Codeine phosphate. Chromatographic demarcation was accomplished on a C18 column [Use BDS Hypersil C18, 5μ, 150 x 4.6 mm] using a mobile phase of methanol: phosphate buffer (60:40, v/v, pH=2.3), the flow rate was 1.1 mL/min, UV detection was at 214 nm. System Suitability tests (SSTs) are typically performed to assess the suitability and effectiveness of the entire chromatography system. The retention time for Piroxicam was found to be 3.95 minutes and 1.46 minutes for Codeine phosphate. The evolved method has been validated through precision, limit of quantitation, specificity, limit of detection linearity and accuracy. (LOD) was 1.92 mg/mL and (LOQ) was 6.336 mg/mL for Piroxicam, whereas (LOD) for Codeine phosphate was 0.29 mg/mL and (LOQ) was 0.95 mg/mL. Piroxicam and Codeine phosphate showed a linear signal in the domain of 5-50 µg/mL for each compound. This research presided to evolve and validate an HPLC method, and the proposed procedure can be used to estimate these drugs in their combined dosage forms.
Background: Clinicians and investigators consider the normal range of bowel habit and frequency as between 3 to 21 motions per week . Stool frequency out side the normal range may be unusual but may not be abnormal in the sense of a disease . And according to the consistency, the normal stool ranges from porridge like to hard and pellety .Objectives: To establish a basic data about the bowel habits (consistency and frequency) in a sample of healthy Iraqi population; in addition to learn about their definition of constipation and diarrhea.Methods: Prospective study from Jan 2000- Jun 2000 at Al-Yarmouk teaching hospital, Baghdad. Questionnaires were distributed to 950 healthy persons of different age group .The questionnaire included: Det
... Show MoreClinicians and investigators consider the normal range of bowel habit and frequency as between 3 to 21 motions per week. Stool frequency outside the normal range may be unusual but may not be abnormal in the sense of a disease, and according to the consistency, the normal stool ranges from porridge like to hard and pellety.
Objectives: To establish a basic data about the bowel habits (consistency and frequency) in a sample of healthy Iraqi population; in addition to learn about their definition of constipation and diarrhea.
Methods: Prospective study from Jan 2000- Jun 2000 at Al-Yarmouk teaching hospital, Baghdad. Questionnaires were distributed to 950 healthy persons of different age group .The questionnaire included: Detailed hi
The modern stylistic lesson has become more committed to the scientific limits in which it believed, and more confident in itself, and it is no longer just a scientific procedure that helps other curricula and sciences that preceded it.
Based on this, our modest research ((a stylistic vision of the objection in the Quranic discourse)) arose to explore an artistic rhetorical phenomenon that was included in the Holy Quran text. ; Because analysis is a situation that allows us to see a lot and absorb the stranger more clearly.
And since the horizontal arrangement of the linguistic elements in which stylistically undistinguished elements meet with distinct ones, the other trend has emerged that believes that the stylistic dis
... Show MoreLand snails constitute an important group of mollusks distributed worldwide. This study reports on land snails found in Iraq. A survey of terrestrial gastropods was performed during their activity seasons in gardens, agricultural lands and nurseries in Iraq from March 2022 to September 2023. Fifteen terrestrial snails belonging to seven families were documented. The species Euchondrus michonii (Bourguignat, 1853) was identified and recorded based on several distinct conchological characters for the first time in Iraq. The recently collected specimens, along with those previously recorded in Iraq, were included in this checklist. Essential information on each species is also presented. As there is no previous checklist or study that
... Show MoreThe rate of gas induction was measured in gas-inducing type mechanically agitated contactors provided with two impellers. A reactor of 0.5 m i.d. was used with a working capacity of 60 liters of liquid. Tap water was used as the liquid phase, and air was used as the gas phase. The bioreactor mixing system consists of two equal diameter stirrers; the top impeller is shrouded-disk/curved-blade turbine with six evacuated bending blades, while the bottom impeller was disk turbine. The impeller speed was varied in the range of 50 to 800 rpm. The ratio of impeller diameter to tank diameter (D/T) and the submergence (S) of upper impeller from the top were varied. The effects of clearance of lower impeller from the tank bottom (C2) an
... Show More