A theoretical study to design a conformal microstrip antennas was introduced in this work. Conformal microstrip antennas define antennas which can be conformed to a certain shape or to any curved surface. It is used in high-speed trains, aircraft, defense and navigation systems, landing gear and various communications systems, as well as in body wearable. Conformal antennas have some advantages such as a wider-angle coverage compared to flat antennas and low radar cross-sectional (RCS) and they are suitable for using in Radome. The main disadvantage of these antennas is the narrow bandwidth. The FDTD method is extremely useful in simulating complicated structures because it allows for direct integration of Maxwell's equations depending on time. The 1x2 cylindrical circular microstrip antennas array is designed and simulated vertically via Finite Difference Time Domain (FDTD) method where can directive antenna be achieved through antennas array design. Mutual coupling between the antennas in the array and the different separation between them were studied. The circular patch is excited by a probe feed method for several reasons including providing less spurious radiation from the probe current, in addition to the simplicity in theoretical engineering installation and practical manufacturing. It is well known that the values of the coupling are decreased as the distance separation increased. Cylindrical circular microstrip antenna with resonant frequency operating is 3.5GHz for mode, several parameters like return loss, band width, and input impedance are calculated. Also, for isolated coupling, mutual coupling coefficients, directivity gain, for different separations between the centers of the two adjacent circular patches in terms the wave length operating are calculated. Moreover, the electromagnetic band gap EBG structure is used for reducing the mutual coupling created by the surface waves in order to enhance the antenna's performance in an array has become smaller than before. The proposed EBG is a three triangular-shape equal sides metallic structure, utilizing the inter-element spacing in an array. The less value of for the spacing between the two centers of patches is . BW percentage increased to 34.3% and the directivity is enhanced also. Additionally, simulations were done using MATLAB 2017b.
E-commerce is the most important result of information technology in this day and age, has resulted in the use of commercial transactions to changes in economic, social, and psychological, and produced a new type of shopping, jobs, and create new job opportunities, and changed the traditional work environment. The challenge currently facing economic units is how to transfer this technology and its integration within the community, especially after the massive developments that have occurred in the areas of commercial and congested markets units, the economic and the products and services the many and varied and intensified competition among these units to achieve a profit, leading to the emergence of e-commerce as on
... Show MoreAbstract—Background: Polycystic ovary syndrome (PCOS) is a prevalent hormonal disorder affecting reproductive- age women, often linked to metabolic issues like insulin resistance. Objective: this study aimed to evaluate ornithine decarboxylase (ODC) and ferric reducing capacity (FRC) levels in women with PCOS, with assess the effects of metformin and Primolut N treatment on their levels. Subjects and Methods: A case− control study was conducted with 150 married Iraqi women, categorized into three groups: 50 healthy controls, 50 untreated PCOS, 50 treated PCOS. Blood samples were analyzed for ODC, FRC levels and hormonal profiles. Statistical analysis applied independent t-test, Pearson’s correlation, ROC curve. Results: The ODC level
... Show MoreEffect of copper doping and thermal annealing on the structural and optical properties of Zn0.5Cd0.5S thin films prepared by chemical spray pyrolysis have been studied. Depositions were done at 250°C on glass substrate. The structural properties and surface morphology of deposited films were studied using X-ray diffraction (XRD) and photomicroscope (PHM) techniques. XRD studies reveal that all films are crystalline tetragonal structure. The film crystallinity are increased with 1% Cu-doping concentration and also increased for the films annealed at 300°C than the other studied cases. The lattice constant 'a' and 'c' varies with doping concentrations from 5.487Å to 5.427Å and 10.871Å to 10.757Å respectively. The grain size attained
... Show MoreThe purpose of this study was to examine the histological structure of the kidney in snake Eryx gaculus gaculus. In present study, the snakes were collected from the city of Baghdad and transferred to the laboratory where their kidneys were dissected out. The samples were then processed to be prepared for histological examination microscopial observations showed that there is no border between the cortex and medulla regions of kidney. The kidney consists of nephrons which are composed of glomerulus surrounded by Bowman’s capsule; the other segments are proximal tubule, distal tubule and connecting tubule. The epithelial tissue lining of these segments simple cuboidal tissue.
Infection with cryptosporidiosis endangers the lives of many people with immunodeficiency, especially HIV patients. Nitazoxanide is one of the main therapeutic drugs used to treat cryptosporidiosis. However, it is poorly soluble in water, which restricts its usefulness and efficacy in immunocompromised patients. Surfactants have an amphiphilic character which indicates their ability to improve the water solubility of the hydrophobic drugs. Our research concerns the synthesis of new cationic Gemini surfactants that have the ability to improve the solubility of the drug Nanazoxide. So, we synthesized cationic Gemini surfactants. N1,N1,N3,N3-tetramethyl-N1,N3-bis(2-octadecanamidoethyl)propane-1,3-diaminium bromide (CGSPS18) and 2,2‘-(etha
... Show MoreSensing insole systems are a promising technology for various applications in healthcare and sports. They can provide valuable information about the foot pressure distribution and gait patterns of different individuals. However, designing and implementing such systems poses several challenges, such as sensor selection, calibration, data processing, and interpretation. This paper proposes a sensing insole system that uses force-sensitive resistors (FSRs) to measure the pressure exerted by the foot on different regions of the insole. This system classifies four types of foot deformities: normal, flat, over-pronation, and excessive supination. The classification stage uses the differential values of pressure points as input for a feedforwar
... Show MoreOffline handwritten signature is a type of behavioral biometric-based on an image. Its problem is the accuracy of the verification because once an individual signs, he/she seldom signs the same signature. This is referred to as intra-user variability. This research aims to improve the recognition accuracy of the offline signature. The proposed method is presented by using both signature length normalization and histogram orientation gradient (HOG) for the reason of accuracy improving. In terms of verification, a deep-learning technique using a convolution neural network (CNN) is exploited for building the reference model for a future prediction. Experiments are conducted by utilizing 4,000 genuine as well as 2,000 skilled forged signatu
... Show MoreStrives Total Productive Maintenance to increase the overall effectiveness of the equipment through the early involvement in the design and manufacture of equipment productivity. It also operates in an environment of simultaneous engineering work on the synchronization of activities to take advantage of early information by maintenance engineers, design, operation, and that helps to reduce the faults and facilitate future maintenance tasks.
Has adopted a search in the theoretical concept of the total maintenance productivity and concurrent engineering activities carried out during which the conjunction a
... Show MoreObjective: This study aimed to evaluate the effectiveness of the Benson Relaxation Technique (BRT) in reducing pain during femoral artery sheath removal after percutaneous coronary intervention (PCI). Methods and Materials: A randomized controlled trial was conducted at three cardiac centers in Iraq. A total of 58 patients undergoing therapeutic PCI were randomly assigned into two groups: intervention (n=27) and control (n=31). The intervention group received BRT for 10 minutes before and after sheath removal. Pain was assessed using the Visual Analogue Scale (VAS) immediately after the procedure. Demographic data and clinical variables were collected. Data were analyzed using SPSS v26 and non-parametric tests (Mann-Whitney U, Krus
... Show More