Breast cancer is the most repeatedly detected cancer category and the second reason cause of cancer-linked deaths among women worldwide. Tumor bio-indictor is a term utilized to describe possible indicators for carcinoma diagnosis, development and progression. The goal of this study is to evaluate part of some cytokines and biomarkers for both serum and saliva samples in breast cancer then estimate their potential value in the early diagnosis of breast cancer by doing more researches in saliva, and utilizing saliva instead of blood (serum and plasma) in sample collection from patients. Serum and salivary samples were taken from 72 patients with breast cancer and 45 healthy controls, in order to investigate the following cytokines such as: interleukin 12 (IL-12), interleukin 6 (IL-6), interleukin 4 (IL-4), 8-hydroxydeoxyguanosine (8-OHdG), tumor necrosis factor (TNF) and interferon-γ (IFN-γ) levels with other bio-pointers such as:
malondialdehyde (MDA), catalase, and 8-nitroguanine (8-NG). The results displayed that the levels of blood and saliva samples of IL-12 (P<0.0001), IL-6 (P<0.0001), IL-4 (P<0.001), 8-OHdG (P<0.0001), 8-NG (P<0.001, and P<0.004), TNF (P<0.002, and P<0.001) and IFN-γ (P<0.0001) were significantly higher in breast cancer, whereas there were significant lowering (P<0.0001) in catalase activates in breast cancer in both samples as compared with healthy subjects. The exchanging of blood to salivary components evaluation in this investigation may be utilized as a diagnostic tool, and designates the potential part for MDA, Catalase, and cytokines as important biochemical in breast cancer. Accordingly, the salivary diagnosis embraces a non-invasive process and tumor progression in breast malignancy patients. Beside saliva may well signify as an active new gate as blood evaluation but easier and cheaper.
A numerical investigation of mixed convection in a horizontal annulus filled with auniform fluid-saturated porous medium in the presence of internal heat generation is carried out.The inner cylinder is heated while the outer cylinder is cooled. The forced flow is induced by thecold outer cylinder rotating at a constant angular velocity. The flow field is modeled using ageneralized form of the momentum equation that accounts for the presence of porous mediumviscous, Darcian and inertial effects. Discretization of the governing equations is achieved usinga finite difference method. Comparisons with previous works are performed and the results showgood agreement. The effects of pertinent parameters such as the Richardson number and internalRay
... Show MoreObjective: To investigate the relation between dyslipidemia and insulin resistance where it is one of the metabolic
disorders in patients with type-ΙΙ diabetes mellitus and compare the results with the control group.
Methodology: Blood samples were collected from (35) patients with type-ΙΙ diabetes mellitus, besides (35) healthy
individuals as a control group were enrolled in this study. The age of all subjects range from (20-50). Serum was
used in determination of glucose, insulin, lipid profile (cholesterol (Ch), triglyceride (TG), high-density lipoprotein
(HDL-Ch), low-density lipoprotein (LDL-Ch) and very low-density lipoprotein (VLDL), for patients and control
groups. Insulin resistance (IR) was calculated acco
Integration of laminar bubbling flow with heat transfer equations in a novel internal jacket airlift bioreactor using microbubbles technology was examined in the present study. The investigation was accomplished via Multiphysics modelling to calculate the gas holdup, velocity of liquid recirculation, mixing time and volume dead zone for hydrodynamic aspect. The temperature and internal energy were determined for heat transfer aspect.
The results showed that the concentration of microbubbles in the unsparged area is greater than the chance of large bubbles with no dead zones being observed in the proposed design. In addition the pressure, due to the recirculation velocity of liquid around the draft
... Show MoreObjective(s): The present study aims at studying the relationship between immunoglobulin IgG, IgA,
IgM , as well as to C-3 and C-4 in brain tumours patients immunity (meningioms and gliomas).
Methodology: Forty sera of brain tumour patients were included 20 glioma and 20 meningioma was
tested to determine the levels of IgM, IgG IgA, C-3 and C-4 by using single radial immune-diffusion
technique and compared with 20 apparently healthy blood donors.
Results: The study revealed a significant decreasing in IgG levels in glioma as compare to meningioma
and control. The concentration of two other serum immunoglobulins and complement in both
meningioma and glioma show no significant differences with those in control group.
Back ground: Several devices with different physical bases have been developed for the clinical measurement of corneal thickness, they classified into 4 categories: Scheimpflug photography based, Slit –Scanning topography, optical coherence tomography (OCT) based and ultrasound (US) based.Objective:To evaluatethe precision of the new Scheimpflug –Placido disc corneal topography in measurement of corneal thickness and to compare the measured values with that obtained by US pachymetry.Methods: Setting of this study is Lasik center in Eye Specialty Private Hospital. Baghdad. Iraq.Eyes of healthy subjects were examined with the Sirius topography.3 consecutive measurements of central (CCT)and thinnest (TCT) corneal thicknesses were obtain
... Show MoreThe main object of this article is to study and introduce a subclass of meromorphic univalent functions with fixed second positive defined by q-differed operator. Coefficient bounds, distortion and Growth theorems, and various are the obtained results.
This paper presents the non-linear finite element method to study the behavior of four reinforced rectangular concrete MD beams with web circular openings tested under two-point load. The numerical finite elements methods have been used in a much more practical way to achieve approximate solutions for more complex problems. The ABAQUS /CAE is chosen to explore the behavior of MD beams. This paper also studies, the effect of both size and shape of the circular apertures of MD beams. The strengthening technique that used in this paper is externally strengthening using CFRP around the opening in the MD beams. The numerical results were compared to the experimental results in terms of ultimate load failure and displace
... Show More